PRO2-P100B25A1 SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Profiler™ DISPLACEMENT MEASUREMENT SENSORS

A B C D E F H I J K L M N O P Q R S T PRO2-P100B25A1 | Profiler™ DISPLACEMENT MEASUREMENT SENSORS

2 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11

Subject to change without notice

Ordering information

Type Part no. PRO2-P100B25A1 6052873 Other models and accessories www.sick.com/Profiler Detailed technical data Performance Measuring range 100 mm, ± 25 mm Measuring width (at measuring distance) 17 mm (75 mm) 22 mm (100 mm) 27 mm (125 mm) Resolution X-direction 25 µm 1) 2) Z-direction 2 µm Linearity X-direction ± 1 % FS 3) 2) 4) Z-direction ± 0.1 % FS Accuracy X-direction ± 5 % FS Z-direction ± 1 % FS Response time 5 ms 5) Light source Laser, red Laser class 2 (EN 60825-1 / 21 CFR 1040.10) 6) Typ. light spot size (distance) 0.3 mm x 32 mm Additional function Timer (ON-OFF delay, one shot, off), averaging 1 … 1,023, sensitivity (adjustable), Measure- ment functions (average, peak height, bottom height, width, peak height position, bottom height position, edge position, edge count, tilt, area, length, diameter) 1) Typical value; actual value depends on settings and environmental conditions. For details see field of view. 2) Measurement on 90 % remission (ceramic, white) 3) Constant ambient conditions. 4) FS = Full Scale = Measuring range of sensor. 5) Typical value, high-res mode. 6) Wavelength: 655 nm, max. output: 1 mW. Interfaces Analog output 1 x 4 mA ... 20 mA (< 300 Ω) 1) Switching output 3 x PNP 2) 1) 24 mA for measuring out of range. 2) Maximum current output 100 mA. 3) Half-duplex (9.6 kbit/s ... 4 Mbit/s)

PRO2-P100B25A1 | Profiler™ DISPLACEMENT MEASUREMENT SENSORS 2016-03-17 13:18:11 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 3 Data interface RS-485 3) External input Selectable from bank, trigger, hold, reset, laser off and offset 1) 24 mA for measuring out of range. 2) Maximum current output 100 mA. 3) Half-duplex (9.6 kbit/s ... 4 Mbit/s) Mechanics/electronics Supply voltage Vs DC 12 V (–5 %) ... DC 24 V (+10 %) 1) Power consumption ≤ 180 mA Warm-up time ≤ 30 min Housing material Die-cast zinc Polycarbonat Connection type Female connector, HRS, 12-pin (I/O, power supply) Indication 2 LEDs (operational status, Laser on/off) Dot matrix display Weight Approx. 300 g Dimensions 40 mm x 60 mm x 94.5 mm 1) When using analog voltage output reduced to 18 V DC (–5%) ... 24 V DC (+10%) Ambient data Enclosure rating IP 67 Protection class III Ambient temperature Operation: –10 °C ... +40 °C Storage: –20 °C ... +60 °C Max. rel. humidity (not condensing) 85 % Temperature drift ± 0.05 % FS/K (FS = Full Scale = Measuring range of sensor) Typ. Ambient light immunity Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx Vibration resistance 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) Shock resistance 50 G (x, y, z axis 3 times each)

A B C D E F H I J K L M N O P Q R S T PRO2-P100B25A1 | Profiler™ DISPLACEMENT MEASUREMENT SENSORS

4 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11

Subject to change without notice Dimensional drawing (Dimensions in mm (inch)) 60 (2.36)5.8 (0.23)2 x Ø 4.2 (0.24) (0.39) 4.5 (0.18) 11.6 (0.46) 25.8 (1.02) 94.5 (3.72) 46.5 (1.83) 84.8 (3.34) ß 40 (1.57) 18.1 (0.71) 4 5 ① LCD ② LED indicator for laser on (green) ③ LED indicator for power on (green) ④ Cursor keys ⑤ Exit button ⑥ Set button ⑦ Male connector, HRS, 6-pin (communication interface) ⑧ Female connector, HRS, 12-pin (I/O, power supply) ⑨ Sender ⑩ Receiver Field of view Sending area (2.95) 100 (3.94) 125 (4.92) Measuring distance in mm (inch) Approx. 32 (1.26) Measuring width in mm (inch)

PRO2-P100B25A1 | Profiler™ DISPLACEMENT MEASUREMENT SENSORS 2016-03-17 13:18:11 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 5 Receiving area Measuring width in mm (inch)/resolution (R) (2.95) 100 (3.94) 125 (4.92) Measuring distance in mm (inch) 17 (0.67)/ 25 μm 22 (0.87)/ 33 μm 27 (1.06)/ 40 μm Connection type 1 2 3 11 12 Connection diagram L+ (12 V … 24 V) 0 V Offset/laser off BANK1/reset BANK2/hold BANK3/trigger Analog ground gray QA Shield brn blu wht vio ora 6gra 7blk 8yel 9red 10 shield 11 wht 12 grn

A B C D E F H I J K L M N O P Q R S T PRO2-P100B25A1 | Profiler™ DISPLACEMENT MEASUREMENT SENSORS

6 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11

Subject to change without notice Recommended accessories Other models and accessories www.sick.com/Profiler Brief description Type Part no. Plug connectors and cables Head A: male connector, HRS, 12-pin Cable: digital I/Os, Power, PVC, no, 2 m STL-OH12-G02M 6053017 Head A: female connector, HRS, 6-pin Head B: male connector, USB, 6-pin Cable: RS-485, PVC, 1.8 m DSL-DH06-G1M8 6053020

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com