TR4-SFU10P SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

NON-CONTACT SAFETY SWITCHES

A B C D E F H I J K L M N O P Q R S T TR4-SFU10P | TR4 Direct NON-CONTACT SAFETY SWITCHES

Ordering information

Type Part no. TR4-SFU10P 6044652 Other models and accessories www.sick.com/TR4_Direct Detailed technical data

Features

System part Sensor and actuator Sensor principle Transponder Number of safe outputs 2 Safe switch on distance Sao 15 mm Safe switch off distance Sar 35 mm Active sensor surfaces 2 Actuation directions 5 Magnetic retaining force ✔ Boundary area indication ✔ Coding Uniquely coded Safety-related parameters Safety integrity level SIL3 (IEC 61508), SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 1.119 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Type Type 4 (EN ISO 14119) Actuator coding level High coding level (EN ISO 14119) Classification in compliance with IEC/ EN 60947-5-3 PDF-M Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state. Functions Cascading ✔ Interfaces Connection type Cable Length of cable 10 m Cable material PVC Long connecting cable ≤ 200 m

2 SAFETY SWITCHES | SICK Online data sheet | 2018-08-31 13:13:28

Subject to change without notice

TR4-SFU10P | TR4 Direct NON-CONTACT SAFETY SWITCHES Status display ✔ Electrical data Protection class III (EN 50178) Classification according to cULus Class 2 Power consumption 50 mA Type of output Semiconductor (OSSD) Output current ≤ 200 mA Response time 60 ms 1) Enable time 360 ms 2) Risk time 60 s 3) Switch-on time 2.5 s 4) Electrical life 10 x 106 switching cycles 1) In a cascade, each downstream safety switch increases the system response time. More response times can be found in the operating instructions. 2) Response time on approach to the enable zone. 3) Detection time for external faults (e.g., short-circuit or cross-circuit of output signal switching devices). Follow the detailed information in the operating instructions. 4) After application of the supply voltage to the safety switch. Mechanical data Design Rectangular Dimensions (W x H x D) 25 mm x 88 mm x 20 mm Weight 687 g Housing material Valox® DR48 Ambient data Enclosure rating IP69K (IEC 60529) NEMA 3 (NEMA 250) NEMA 4X (NEMA 250) NEMA 12 (NEMA 250) NEMA 13 (NEMA 250) Ambient operating temperature –10 °C ... +55 °C Vibration resistance 10 Hz ... 55 Hz, 3.5 mm (IEC 60068-2-6) Shock resistance 30 g, 11 ms (EN 60068-2-27) Classifications ECl@ss 5.0 27272403 ECl@ss 5.1.4 27272403 ECl@ss 6.0 27272403 ECl@ss 6.2 27272403 ECl@ss 7.0 27272403 ECl@ss 8.0 27272403 ECl@ss 8.1 27272403 ECl@ss 9.0 27272403 ETIM 5.0 EC001829 ETIM 6.0 EC001829 2018-08-31 13:13:28 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 3

A B C D E F H I J K L M N O P Q R S T TR4-SFU10P | TR4 Direct NON-CONTACT SAFETY SWITCHES UNSPSC 16.0901 39122205 Dimensional drawing (Dimensions in mm (inch)) 20.725.0 4.6 88.1 M12 x 1 9.7 10.0 4.6 5.1 4.6 58.0 62.5 78.0 82.6 13.4 Plug version 10.7 18.5 18.5 88.1 10.7 7.1 6.8 4.6 5.1 4.6 68.3 72.9 78.0 20.725.0 Response range Switch-on distance [mm] Alignment offset [mm] Side approaches Area for the boundary area indication Safe switch-on distance 15 mm ao S If the actuator moves laterally in relation to the surface of the sensor, a minimum distance of 9 mm must be maintained. This dis- tance will prevent premature triggering due to the side approach areas.

4 SAFETY SWITCHES | SICK Online data sheet | 2018-08-31 13:13:28

Subject to change without notice

TR4-SFU10P | TR4 Direct NON-CONTACT SAFETY SWITCHES Connection diagram White Brown Green Yellow Grey Pink Blue Red Aux output (not safe) Voltage supply 24 V DC Not connected Enable input for channel B Safety output A Safety output B Voltage supply 0 V DC Enable input for channel A WH BN GN YE GY PK BU RD 2018-08-31 13:13:28 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 5

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com