A B C D E F H I J K L M N O P Q R S T WFM30-40P321 | WFM FORK SENSORS Illustration may differ

Ordering information

Type Part no. WFM30-40P321 6037819 Other models and accessories www.sick.com/WFM Detailed technical data

Features

Functional principle Optical detection principle Dimensions (W x H x D) 10 mm x 50 mm x 59.5 mm Housing design (light emission) Fork shaped Fork width 30 mm Fork depth 42 mm Minimum detectable object (MDO) 0.8 mm Light source LED, visible red light Adjustment None Output function Dark switching Interfaces IO-Link functions — Advanced functions — Fieldbus, industrial network - Type of fieldbus integration - Mechanics/electronics Supply voltage 10 V DC ... 30 V DC 1) Ripple < 10 % 2) Power consumption < 20 mA 3) Switching frequency 4 kHz 4) 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A. 2) May not exceed or fall below Uv tolerances. 3) Without load. 4) With light/dark ratio 1:1. 5) Signal transit time with resistive load. 6) Reference voltage DC 50 V. 7) Depending on fork width.

2 REGISTRATION SENSORS | SICK Online data sheet | 2018-07-08 09:57:24

Subject to change without notice

WFM30-40P321 | WFM FORK SENSORS Response time 125 µs 5) Stability of response time ± 15 µs Switching output PNP Switching output (voltage) PNP: HIGH = VS – ≤ 1.5 V / LOW = 0 V NPN: HIGH = approx. VS / LOW ≤ 1.5 V Switching output Dark switching Output current Imax. 100 mA Initialization time 140 ms Connection type Connector M8, 3-pin Ambient light immunity Sunlight: ≤ 10,000 lx Protection class III 6) Circuit protection UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression Enclosure rating IP67 Weight Approx. 80 g ... 190 g 7) Housing material Aluminum 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A. 2) May not exceed or fall below Uv tolerances. 3) Without load. 4) With light/dark ratio 1:1. 5) Signal transit time with resistive load. 6) Reference voltage DC 50 V. 7) Depending on fork width. Ambient data Ambient operating temperature –10 °C ... +60 °C 1) Ambient storage temperature –40 °C ... +80 °C Shock load According to EN 60068-2-27 UL File No. NRKH.E191603 & NRKH7.E191603 1) Do not bend below 0 °C. Classifications ECl@ss 5.0 27270909 ECl@ss 5.1.4 27270909 ECl@ss 6.0 27270909 ECl@ss 6.2 27270909 ECl@ss 7.0 27270909 ECl@ss 8.0 27270909 ECl@ss 8.1 27270909 ECl@ss 9.0 27270909 ETIM 5.0 EC002720 ETIM 6.0 EC002720 UNSPSC 16.0901 39121528 2018-07-08 09:57:24 | Online data sheet Subject to change without notice REGISTRATION SENSORS | SICK 3

A B C D E F H I J K L M N O P Q R S T WFM30-40P321 | WFM FORK SENSORS Dimensional drawing (Dimensions in mm (inch)) (0.39) 10.5 (0.41) 10.5 (0.41) a CC2 C3 C1 (0.32) 3 (0.12) A 12.1 (0.48) b 4 (0.16) 13.5 (0.53) B 8.2 (0.32) Dimensions in mm (inch) A B C C1 Fork width Fork depth WFM30 30 42 30 6.5 WFM50 50 60 40 6.5 WFM80 80 60 70 6.5 WFM120 120 124.3 100 17 WFM180 180 124.3 152 22 C2 C3 a b WFM30 – – 54 67.7 WFM50 8 19.5 74 85.7 WFM80 8 19.5 104 85.7 WFM120 10 17 144 150.2 WFM180 8 22 204 150.2 ① Optical axis ② Mounting hole, Ø 4.3 mm ③ WFM50/80/120/180 ④ Transmitted light (red) ⑤ Function signal indicator (yellow), switching output Connection diagram cd-045 + (L+) - (M) Q BN BU BK

4 REGISTRATION SENSORS | SICK Online data sheet | 2018-07-08 09:57:24

Subject to change without notice

WFM30-40P321 | WFM FORK SENSORS Recommended accessories Other models and accessories www.sick.com/WFM Brief description Type Part no. Plug connectors and cables Head A: female connector, M8, 3-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 2 m YF8U13-020VA1XLEAX 2095860 Head A: female connector, M8, 3-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 5 m YF8U13-050VA1XLEAX 2095884 Head A: female connector, M8, 3-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 10 m YF8U13-100VA1XLEAX 2095885 Head A: female connector, M8, 3-pin, angled, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 2 m YG8U13-020VA1XLEAX 2096165 Head A: female connector, M8, 3-pin, angled, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 5 m YG8U13-050VA1XLEAX 2096166 Head A: female connector, M8, 3-pin, angled, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 10 m YG8U13-100VA1XLEAX 2096209 Head A: female connector, M8, 3-pin, straight Head B: - Cable: unshielded DOS-0803-G 7902077 Head A: female connector, M8, 3-pin, angled Head B: - Cable: unshielded DOS-0803-W 7902078 2018-07-08 09:57:24 | Online data sheet Subject to change without notice REGISTRATION SENSORS | SICK 5

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com