A B C D E F H I J K L M N O P Q R S T UE23-3MF2D2 | UE23-3MF SAFETY RELAYS Illustration may differ

Ordering information

Type Part no. UE23-3MF2D2 6034595 Other models and accessories www.sick.com/UE23-3MF Detailed technical data Safety-related parameters Safety integrity level SILCL2 (EN 62061) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) B10d parameter 3 x 105 switching cycles (AC-15, 230 V, I = 5 A) 2 x 106 switching cycles (DC-15, 230 V, I = 2 A) 7 x 106 switching cycles (DC-13, 24 V, I = 1 A) PFHD (mean probability of a dangerous fail- ure per hour) 2.0 x 10-7 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Stop category 0 (EN 60204-1) Interfaces Connection type Fixed screw terminals Number of enable current (N/O) contacts 3, relevant for safety Electrical data Operating data Supply voltage VS A1, A2 24 V DC (19.2 V DC ... 30 V DC) Residual ripple (≤ 2.4 Vpp) 1) Power consumption (≤ 1 W) Overvoltage category II Rated insulation voltage Ui 300 V AC Rated impulse withstand voltage Uimp 4 kV Test voltage 2.2 kV (50 Hz) (EN 60439-1) 1) In DC operation, within the limits of VS.

2 SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK Online data sheet | 2018-09-11 15:13:28

Subject to change without notice

UE23-3MF2D2 | UE23-3MF SAFETY RELAYS Control voltage: Y1 - Y2 - Y3 Control voltage UV - 2 V DC ... UV Control current ≤ 20 mA Short-circuit current ≤ 250 mA Short-circuit protection 8 A gG, with tripping characteristics B or C Reset time Manual ≤ 70 ms Automatic ≤ 600 ms Electrical output circuits: 13/14, 23/24, 31/32 Response time (≤ 80 ms) 1) Number of enable current (N/O) contacts 3, relevant for safety Number of signalling current (N/C) contacts 1, not safety-relevant Contact type Positively driven Contact material Silver alloy, gold flashed Switching voltage Enable current contact 5 V AC ... 230 V AC 5 V DC ... 300 V DC Signalling current contact 5 V AC, 5 V DC ... 230 V AC, 300 V DC Current-carrying capacity per OSSD Enable current contact 10 mA ... 8 A Signalling current contact 10 mA ... 5 A Usage category AC-15/DC-13 (EN 60947-5-1) Rated operating current (voltage) 5 A (230 V AC) 360 switching cycles/h

5 A (24 V DC) 360 switching cycles/h

Switching frequency ≤ 3600/h Mechanical life (relay contacts) 1 x 107 switching cycles Electrical life (relay contacts) 1 x 106 switching cycles 1) K1/K2. Mechanical data Dimensions (W x H x D) 22.5 mm x 123 mm x 93.5 mm Weight 0.2 kg Classifications ECl@ss 5.0 27371990 ECl@ss 5.1.4 27371990 ECl@ss 6.0 27371819 ECl@ss 6.2 27371819 ECl@ss 7.0 27371819 ECl@ss 8.0 27371819 ECl@ss 8.1 27371819 ECl@ss 9.0 27371819 ETIM 5.0 EC001449 ETIM 6.0 EC001449 2018-09-11 15:13:28 | Online data sheet Subject to change without notice SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK 3

A B C D E F H I J K L M N O P Q R S T UE23-3MF2D2 | UE23-3MF SAFETY RELAYS UNSPSC 16.0901 41113704 Dimensional drawing (Dimensions in mm (inch)) Safety relay (3.25) 82.5 (3.67) 93.3 (3.8) 96.5 (1.9) 48.3 (2.63) 66.7 (2.48) (4.24) 107.6 (2.96) 75.3 (0.89) 22.5 (3.69) 93.6 (4.49) 114 Connection diagram Supply Reset Control-Logic A2 Y1 Y2 Y3 13 23 33 41 14 24 34 42

4 SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK Online data sheet | 2018-09-11 15:13:28

Subject to change without notice

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com