603 ADVANCEDENERGY | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
©2020 Advanced Energy Industries, Inc. The Trek® 603 is a high-voltage DC power amplifier/piezo driver designed to provide precise control of output voltages in bipolar or unipolar ranges that are customer specified within a range of available settings. The instrument achieves the accurate output responses and high slew rates demanded by reactive loads by utilizing a four-quadrant active output stage that sinks or sources current into reactive or resistive loads. The Trek 603 is configured as a non-inverting amplifier and is available in single or dual channel packaging that are operable on a bench top or in a 19 in rack. PRODUCT HIGHLIGHTS Four-quadrant output for driving capacitive loads Up to two independent amplifier channels in one enclosure Short-circuit protected for equipment protection Reprogrammable factory-set output configurations All solid-state design for maintenance free operation Low output noise for ultra-accurate outputs NIST-traceable Certificate of Calibration provided with each unit TYPICAL APPLICATIONS Driving piezoelectric actuators Modulating electrooptics Electrostatically controlling ion beams Providing remote ON/OFF capabilities for automated or computer controlled systems Available Voltage Ranges 0 to ±125 VDC or peak AC 0 to -250 VDC or peak AC 0 to +250 VDC or peak AC Output Current Range 0 to ±40 mA DC or ±80 mA peak AC for less than 1 ms Slew Rate Greater than 100 V/μs Large Signal Bandwidth (5%) DC to greater than 150 kHz DC Voltage Gain
50 V/V or 25 V/V
High voltage power amplifier/piezo driver for precise control of output voltages in customer specified bipoloar or unipolar ranges within available ranges.
2 advancedenergy.com TREK 603 HIGH VOLTAGE POWER AMPLIFIER TECHNICAL DATA Performance Specifications Available Output Voltage Ranges 0 to ±125 VDC or peak AC 0 to -250 VDC or peak AC 0 to +250 VDC or peak AC Output Current ±40 mA DC or ±80 mA peak AC, for less than 1 ms DC Voltage Gain 50 V/V (a gain of 25 V/V is available) DC Voltage Gain Accuracy Better than 0.1% of full scale DC Offset Voltage Less than 500 mV Output Noise Less than 20 V rms Slew Rate Greater than 100 V/μs (10% to 90%, typical) Large Signal Bandwidth DC to greater than 150 kHz (5% distortion) Stability Drift with Time: Less than 100 ppm/hr, noncumulative Drift with Temp: Less than 25 ppm/°C Amplifier Input Input Voltage Range 0 to ±10 V DC or peak AC, non-inverting Input Impedance 10 kW, nominal Voltage Monitor Specifications Ratio 1/25th of the high voltage output DC Accuracy Better than 0.1% of full scale AC Accuracy Calibrated using a Ross Model VD30-4.1-BDKC-ALU high voltage divider DC Offset Voltage Less than 5 mV Output Noise Less than 5 mV rms Output Impedance 0.1 W Current Monitor Specifications Ratio 0.1 V/mA DC Accuracy Greater than 1% of full scale Offset Voltage Less than 10 mV Output Noise Less than 10 mV rms Output Impedance 0.1 W Mechanical Specifications Dimensions (H x W x D) Single Channel Instrument 222.3 x 108 x 381 mm (8.75 x 4.25 x 15 in) Double Channel Instrument 433.8 x 108 x 335 mm (17 x 4.25 x 15 in) Weight Single Channel Instrument 4.3 kg (9.4 lb) Double Channel Instrument 8.6 kg (18.8 lb) HV Connector SHV High Voltage Connector BNC Connectors Power Switch, Amplifier Input, Voltage Monitor, Current Monitor, High Voltage ON/OFF , Digital Enable Measured using the true rms feature of the HP Model 34401A digital multimeter
advancedenergy.com 3 TREK 603 HIGH VOLTAGE POWER AMPLIFIER Electrical Specifications Line Voltage Factory set for one of two ranges: 104 to 127 VAC or 180 to 250 VAC at 48 to 63 Hz AC Line Receptacle Standard three-prong with integral fuse holder Power Consumption 125 VA, maximum HV Cable 2 m, 66 pF per foot Environmental Specifications Temperature 0 to 40°C (32 to 104°F) Relative Humidity To 85%, noncondensing Altitude To 2000 meters (6561.68 ft)
Features
Output Voltage Configurations Factory set for 0 to ±125 VDC or peak AC. Other ranges available. Digital Enable An input providing a connection for a TTL compatible signal to turn on and off the high voltage output. Load Range Switch Slide switch to select high or low capacitive loads (more than 150 pF or less than 150 pF) Dynamic Adjustment Graduated one-turn panel potentiometer is used to optimize the AC response for various load parameters. TECHNICAL DATA REFERENCE NUMBERS Included Accessories PN Description
23166 Operator's Manual
43874 HV Output Cable
N5002 Line Cord Spare Fuses (selected per geographic destination) Optional Accessories PN Description 603RA 19 in Rack Mount Kit 604RA Full Rack Mount Kit (3.5 in Buckeye) 603RA-2 Dual Instrument Rack Kit
ENG-HV-Trek-603C-235-01 8.20 For international contact information, visit advancedenergy .com. sales.support@aei.com +1 970 221 0108 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, Trek®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc. MODEL 603