AOD-N1 SICK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
DISPLACEMENT MEASUREMENT SENSORS
A B C D E F H I J K L M N O P Q R S T AOD-N1 | OD Max DISPLACEMENT MEASUREMENT SENSORS
2 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11
Subject to change without notice
Ordering information
Type Part no. AOD-N1 6028961 Other models and accessories www.sick.com/OD_Max Detailed technical data
Features
System part Amplifier unit Performance Response time 0.5 ms 1) Measuring frequency 10 kHz Output time ≤ 0.1 ms Additional function Arithmetic calculations, Mean-value setting 1 … 4,096x, Frequency filters, automatic sensitivity adjustment, manual sensitivity adjustment, Time functions, 8 memory banks, Hold functions, Peak-to-peak measurement, Peak height measurement, Bottom measurement, Analog outputs can be taught in, Switching outputs can be taught in, set hysteresis, Internal data recorder, switching mode: distance to object (DtO), switching mode: window (Wnd) Note Required for OD350-x, OD85-x, OD30-x 1) Automatic sensitivity adjustment ≤ 2 ms. Interfaces Resolution analog output 16 bit Switching output 5 x NPN (100 mA) 2) Error output (max. output current) 2 x alarm Reference input 2 x zero-ref Input for memory bank selection 3 x bank Hold input 2 x hold, 1 x hold-reset Data interface RS-232 1) Source of analog output is either sensor heads, or calculation result. 2) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS. Mechanics/electronics Supply voltage Vs DC 12 V ... 24 V 1) Power consumption 6 W 2) Warm-up time ≤ 5 min Housing material Polycarbonat and nylon 66 2) When connected with two sensor heads, incl. analog current output. 3) Inclusive terminal board.
AOD-N1 | OD Max DISPLACEMENT MEASUREMENT SENSORS 2016-03-17 13:18:11 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 3 Connection type Terminal board Indication 1,4'' color display Weight 240 g 3) 2) When connected with two sensor heads, incl. analog current output. 3) Inclusive terminal board. Ambient data Enclosure rating IP 20 Protection class III Ambient temperature Operation: –10 °C ... +45 °C Storage: –20 °C ... +60 °C Relative air humidity (non-condensing) 35 % ... 85 % Vibration resistance 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) Shock resistance 50 G (x, y, z axis 3 times each) General notes Note on use OD Max sensor head OD25-x is only to be used with AODG-P/N1; All other types (OD350-x, OD85-x, OD30-x) are to be used with AOD-P/N1 Dimensional drawing (Dimensions in mm (inch)) AOD-xx AODG-xx /c52 /c53 /c54 /c51 /c51 /c50 /c49 65.4 (2.57) 22 (0.87)27.4 (1.08) 7.7 (0.30) 14.7 (0.58) 4.5 (0.18) (3.07) 19.1 (0.75) (0.79) 27.4 (1.08) 6.2 (0.24) ① DIN rail mounting ② LC display ③ Terminal board (detachable) ④ RS-232C interface ⑤ Sensor head B connection port ⑥ Sensor head A connection port
A B C D E F H I J K L M N O P Q R S T AOD-N1 | OD Max DISPLACEMENT MEASUREMENT SENSORS
4 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11
Subject to change without notice Connection type Evaluation unit RS-232C Terminal block evaluation unit L R Connection diagram Terminal block connection diagram L GND1 12 V ... 24 V2 JDGE 1 3 JDGE 2 4 JDGE 3 5 JDGE 4 6 JDGE 5 7 ALM A 8 ALM B 9 ANG (V) 10 ANG (mA) 11 GND 12 R GND1 ANG (V) 2 ANG (mA) 3 nc 4 BANK 0 5 BANK 1 6 BANK 2 7 HOLD A 8 RST 9 HOLD B 10 ZERO A 11 ZERO B 12 ① Ground (0 V) ② Judgement Output = switching output ③ Alarm output ④ Analog output ⑤ Not assigned
AOD-N1 | OD Max DISPLACEMENT MEASUREMENT SENSORS 2016-03-17 13:18:11 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 5 Evaluation unit RS-232C nc RXD TXD nc GND nc nc nc nc 9 ① Not assigned Adjustment possible AOD-xx AODG-xx /c55 SELECT SET/RUN 1 2 3 ADJUST MODE BANK LOCK ZERO A ZERO B ⑦ Operating elements Recommended accessories Other models and accessories www.sick.com/OD_Max Brief description Type Part no. Adapters and distributors TERM.-AOD/AODG 6033129 Plug connectors and cables Head A: female connector, M12, 10-pin, straight Head B: male connector, M12, 10-pin, straight Cable: unshielded, 2 m DSL-1210-G02M 6028943 Head A: female connector, M12, 10-pin, straight Head B: male connector, M12, 10-pin, straight Cable: unshielded, 5 m DSL-1210-G05M 6028944
A B C D E F H I J K L M N O P Q R S T AOD-N1 | OD Max DISPLACEMENT MEASUREMENT SENSORS
6 DISTANCE SENSORS | SICK Online data sheet | 2016-03-17 13:18:11
Subject to change without notice Brief description Type Part no. Head A: female connector, M12, 10-pin, straight Head B: male connector, M12, 10-pin, straight Cable: unshielded, 10 m DSL-1210-G10M 6033614
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com