59085-1-T-S-A HAMLIN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Features
- Sensor and magnet contained in single housing
- Sensor operates when ferrous vane passes through slot
- Normally open, normally closed or change over options
- Choice of cable length and connector Benefits
- Quick and reliable single screw mounting with location feature
- No standby power requirement
- Hermetically sealed, magnetically operated contacts continue to operate long after optical and other technologies fail due to contamination
Applications
- Position and limit sensing
- Security system switch
- Linear actuators
- Industrial process control
- Shaft rotation sensing
59085 Vane Sensor Features and Benefits
59085 Sensor
.285 (7.3) MAX Mu METAL 1.0 SQ x .062 VANE MOVEMENT 59085 ISSUE No: 4 DATE: 1/5/3 TABLE 1 Form A Normally Change Normally Normally Contact T ype Open Over Closed Closed H.V. Switch Type 13 4 5 Power Watt - max. 5 5 10 10 Voltage Switching Vdc - max. 175 175 200 300 Breakdown Vdc - min. 200 200 250 450 Insulation Ω - min. 10 T emperature Operating °C -40 to +105 -40 to +105 -40 to +105 -20 to +105 Storage °C -65 to +105 -65 to +105 -65 to +105 -65 to +105 Shock 11ms 1⁄2 sine G - max. 50 50 100 100 Vibration 50-2000 Hz G - max. 30 30 30 30