0985S4742100 BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Product: 0985 S4742 100 Fast Ethernet Cat5e Data Double-Ended Cordset: Male straight D-coded black M12 Standard to male straight D-coded black M12 Standard, shielded, 50 V AC / 60 V DC, 4 A; TPE green cable, 4-wires, 0.38 mm² Product Description Fast Ethernet Cat5e Data Double-Ended Cordset: Male straight D-coded black M12 Standard to male straight D-coded black M12 Standard, shielded, 50 V AC / 60 V DC, 4 A; TPE green cable, 4-wires, 0.38 mm² Technical Drawing Technical Specifications Face View Side 1 Pin 1 Pin 2 Pin 3 Pin 4 yellow white orange blue Face View Side 2 Pin 1 Pin 2 Pin 3 Pin 4 yellow white orange blue

Product Family: Data Connectors Brand: Lumberg Automation Connector Type: Cordset, double ended Shielding: Shielded Rated Voltage: 60 V Rated Impulse Voltage: 1.5 kV Operating Voltage: 50 V AC / 60 V DC Rated Current*: 4 A Data Transmission: Fast Ethernet Cat5e Data Transmission Rate: 100 Mbit/s Technical Data Side 1 Product Sub Family: M12 Standard Type of Contact / Gender: Male Connector Design: Straight Attachment Type: Coupling Screw Number of Pins: 4 Coding: D Contact Resistance: ≤ 10 mOhm Insulation Resistance: ˃ 10^9 Ohm Mating Cycles: ≤ 100 Ambient Temperature (Operation)*: - 40 °C - + 90 °C Protection Degree / IP Rating**: IP65, IP67, IP69K Design Standard: IEC 61076-2-101 Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1) Overvoltage Category: III acc. to DIN EN 60664-1 (VDE 0110-1) Contact Base Material: CuSn Contact Plating: Cu/Au Contact Bearer Material: PBT Contact Bearer Color: Black Flammability Class (Contact Bearer): UL 94 HB Molded Body Material: TPU Molded Body Color: Black Flammability Class (Molded Body): UL 94 HB Attachment Material: CuZn Attachment Plating: Nickel-plated Shielding Material: CuZn, tin-plated Fastening Torque (Attachment): M 12x1: (50-60) Ncm, hand-tight Note: Do not connect or disconnect under load. Cable Data Cable Number: 542 Conductor Size: 0.38 mm² Number of Wires: 4 Minimal Bending Radius (Fixed Inst): ˃ 30 mm Minimal Bending Radius (Flexible Inst): ˃ 60 mm Cycles (Bending): ˃ 5 M Conductor material: Cu Cable Jacket Material: TPE Cable Jacket Color: green matt similarly RAL 6018 Cable Diameter D: ø 6.50 ± 0.20 mm Wire Insulation Material: PP Insulated Wire Diameter: ø 1.50 mm Overall Shield (Cable): Cu-ETP1 tinned Foil shield: Al-PT Foil

Ambient Temperature (Fixed Installation): - 40 °C - + 90 °C (UL: + 80 °C) Ambient Temperature (Flex Installation): - 40 °C - + 90 °C (UL: + 80 °C) Ambient Temperature (Drag Chain Inst): - 25 °C - + 60 °C Flammability Class (Cable Jacket): CM (UL 1685) Cable Characteristics: Exclusion of dangerous materials; Sunlight resistance: UL 1581 sec. 1200 Core Colors: white, blue, yellow, orange Technical Data Side 2 Product Sub Family, Side 2: M12 Standard Type of Contact / Gender, Side 2: Male Connector Design, Side 2: Straight Attachment Type, Side 2: Coupling Screw Number of Pins, Side 2: 4 Coding, Side 2: D Contact Resistance, Side 2: ≤ 10 mOhm Insulation Resistance, Side 2: ˃ 10^9 Ohm Mating Cycles, Side 2: ≤ 100 Ambient Temperature (Operation), Side 2*: - 40 °C - + 90 °C Protection Degree / IP Rating, Side 2: IP65, IP67, IP69K Design Standard, Side 2: IEC 61076-2-101 Pollution Degree, Side 2: 3 acc. to DIN EN 60664-1 (VDE 0110-1) Overvoltage Category, Side 2: III acc. to DIN EN 60664-1 (VDE 0110-1) Contact Base Material, Side 2: CuSn Contact Plating, Side 2: Cu/Au Contact Bearer Material, Side 2: PBT Contact Bearer Color, Side 2: Black Flammability Class (Contact Bearer), Side 2: UL 94 HB Molded Body Material, Side 2: TPU Molded Body Color, Side 2: Black Flammability Class (Molded Body), Side 2: UL 94 HB Attachment Material, Side 2: CuZn Attachment Plating, Side 2: Nickel-plated Shielding Material, Side 2: CuZn, tin-plated Fastening Torque (Attachment), Side 2: M 12x1: (50-60) Ncm, hand-tight Safety & Environmental Compliance RoHS Compliant: yes Resistances Oil Resistance: UL OIL RES I Notes Protection Degree / IP Rating Note: only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. Note Derating: Notice derating History Update and Revision: Revision Number: 0.55 Revision Date: 02-03-2025 Variants Item # Item Description Cable Length 8400 0985 S4742 100/0,3 M 0.3 m 4947 0985 S4742 100/0,5 M 0.5 m 3358 0985 S4742 100/0,6 M 0.6 m 3359 0985 S4742 100/1 M 1 m 8009 0985 S4742 100/1,5 M 1.5 m 3360 0985 S4742 100/2 M 2 m 4622 0985 S4742 100/3 M 3 m 3361 0985 S4742 100/4 M 4 m 2051 0985 S4742 100/5 M 5 m

5902 0985 S4742 100/6 M 6 m 5903 0985 S4742 100/7 M 7 m 5904 0985 S4742 100/8 M 8 m 2052 0985 S4742 100/10 M 10 m 8553 0985 S4742 100/12 M 12 m 15275 0985 S4742 100/14 M 14 m 2059 0985 S4742 100/15 M 15 m 15272 0985 S4742 100/18 M 18 m 2060 0985 S4742 100/20 M 20 m 20626 0985 S4742 100/23 M 23 m 2061 0985 S4742 100/25 M 25 m 5412 0985 S4742 100/30 M 30 m 6953 0985 S4742 100/35 M 35 m 2065 0985 S4742 100/40 M 40 m 15539 0985 S4742 100/45 M 45 m 2066 0985 S4742 100/50 M 50 m 9670 0985 S4742 100/60 M 60 m 12685 0985 S4742 100/70 M 70 m 15612 0985 S4742 100/75 M 75 m 12686 0985 S4742 100/80 M 80 m 12687 0985 S4742 100/90 M 90 m © 2025 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.