www.protekdevices.com 05016.R4 12/03 587B051 thru 587B301 DEVICE CHARACTERISTICS ARRESTER DEFINITIONS Clamping Voltage: The clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. Standard Wave Form: The waveform of a surge current or voltage is designated by a combination of two numbers. The first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. The second number is for the time of the wavetail also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 µs waveform. Transient Current: The transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs. OPERATION For maximum effectiveness, the protector should be installed directly after the AC line on/off switch and fuse. This will protect the electronics from the AC line switch arcing and the severe transients caused by a fuse clearing. Some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85°C. The case temperature is measured at the center of the mounting surface. The unit should not be mounted to a low combusting temperature material such as wood. High energy transients will cause a large circulating current in the AC input line (2,500A is possible). To prevent electromagnetic coupling, the AC line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. In addition, the electrical service must be connected to a low impedance earth ground. FILTER CHARACTERISTICS (Noise Attenuation dB) MAXIMUM RATINGS SPECIFICATIONS @ 25°C RESPONSE TO TRANSIENT VOLTAGES CLAMPING TEST CONDITION DIFFERENTIAL (Line-to-Neutral) COMMON (Neutral-to-Ground) Operating Line Voltage: Maximum Line Current: (Line-to-Neutral Only) Transient Voltage: Transient Current: Current Leakage: Line-to-Neutral: Neutral-to-Ground: Storage & Operating Temperature: (Measured at center of mounting surface)
130 VAC Max
587B051: 5A 587B151: 15A 587B201: 20A 587B301: 30A 6000Vpeak 3000Apeak @ 130 VAC 1.0mA 0.5mA -40°C to 85°C PROTECTION MODE MAXIMUM CLAMPING VOLTAGE OPEN CIRCUIT VOLTAGE @ 1.2/50 µs SHORT CIRCUIT CURRENT @ 8/20 µs Frequency (MHz) Common Mode Attenuation Differential Mode Attenuation 0.15 0.5 1.0 5.0 295V 350V 500V 650V 1000V 6000V 1000V 6000V 500A 3000A 500A 3000A
www.protekdevices.com 05016.R4 12/03 587B051 thru 587B301 COPYRIGHT © ProTek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products. PACKAGE OUTLINE & DIMENSIONS ProTek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com NEUTRAL 120V 50/60 Hz
5 AMP
A B C D 0.169” Nom. Dia.
2 Places
2 NUTS, 2 WASHERS
E F PROTEK PART NUMBER CASE (INCHES) CASE (CENTIMETERS) APPROX. WEIGHT IN GRAMS TERMINAL THREADS 587B051 587B151 587B201 587B302 A B C 2.5 3.5 3.5 3.5 D 2.85 3.85 3.85 3.85 E 1.5 1.5 1.5 1.5 F 0.6 0.6 0.6 0.6 A 5.08 7.62 7.62 7.62 B 5.08 5.08 7.62 7.62 C 6.35 8.89 8.89 8.89 D 7.62 10.16 10.16 10.16 E 3.81 3.81 3.81 3.81 F 1.52 1.52 1.52 1.52 250 500 750 850 #8-32 #8-32