Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
2 738A INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS Programming Options Use this section for reference when programming the module. INIT ALL? NO YES INITIALIZATION Select YES to reset all programming options to the factory default. Select NO to maintain all programming options at their current settings. BUS: *KYPD LX PANEL BUS TYPE Select the type of connection from the panel to the module. Choose either Keypad Bus or LX‑Bus connection. Press the CMD key to accept the selection. An asterisk displays to the left of the bus type selected. Note: If the 738A will be used on the keypad bus, ensure it is programmed as a device in Device Setup. HOUSE ID: 01 HOUSE ID Select a number from 01 to 31 for the House ID. Enter a leading zero for numbers less than ten. The factory default is 01. The same House ID number must be programmed into any 5804BD Wireless Key transmitters to receive Armed, Alarm, and Ready to Arm status. Refer to the Ademco 5804BD Installation Instructions to enter the House ID. ZONE? TEST ADD ZONE TEST OR ADD Select ADD to program new zones into the system or select TEST to perform a zone test on existing zones. When performing a Zone Test, the 5881 receiver signal gain is reduced by 50%. When adding new zones to the system, select TEST to perform the Zone Test. TRIPS END ZONE TEST TRIPS COUNTER When TEST is selected, the Zone Test Trips Counter displays the number of times any programmed zone trips (alarm/short) during the Zone Test. The keypad buzzer sounds for 1 second each time a programmed zone trips. Select END to stop the zone test and display any failed zones. Note: When the keypad is removed from the module, the 5881 receiver signal gain automatically returns to 100%. ZONE: XX ‑FAIL ZONE TEST FAIL The zone number of any zone that failed to trip at least once during the test displays for four seconds and the buzzer sounds for one second. The next failed zone displays. Press CMD to advance to the next failed zone. PROGRAM THE MODULE DMP BUS Ademco Reciever Model 738A PROG RECEIVER Model 330 Programming Harness PROGRAM 5800TM TransmitterTo Keypad Bus or LX Bus Model 300 4-Wire Harness To Keypad DMP Model 300 W ire Color Ademc o Harness W ire Color R ed R ed Y ello w Y ello w Gr een Gr een Black Black N/ A Blue Figure 4: 738A Wiring
738A INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3 ZONE NO: ZONE NUMBER After selecting ADD, enter a wireless transmitter zone number to be programmed into the module at the Zone Number option. Press CMD to accept the zone number. This zone number must correspond to a zone number programmed into the panel. When the module is connected to the Keypad Bus and any wireless input zones for a particular address are programmed (Ex: 11‑14 = Addr 1), the module responds to polls for this address. Other devices, such as keypads, cannot use this address. For more information about addressing the module, refer to Table 1 and Table 2. *UN RF UR BR TRANSMITTER TYPE Enter a transmitter type by pressing the select key that corresponds to the type of transmitter used. An asterisk appears to the left of the transmitter type chosen. Default is UN. Press the CMD key to accept the selection. Refer to the installation instructions provided with the Ademco transmitter for additional information. UN = Unused Zone UR = Unsupervised Transmitter RF = Supervised Transmitter BR = Button Transmitter When a transmitter reed switch, contact, or button is in a faulted condition, the corresponding panel zone is SHORTED. When the transmitter tamper is in a faulted condition, the corresponding panel zone is OPEN. Note: Supervised transmitters need to report to the module at least once every 12 hours. If not, the DMP panel indicates that the zone is missing. LEARN ID? NO YES TRANSMITTER IDENTIFICATION NUMBER TRANSMIT NOW Select YES to enter Learn ID programming. The keypad displays TRANSMIT NOW. For the module to learn the transmitter identification number, the transmitter input (reed switch or contact) must be activated (tripped) and restored. The first activation beeps the program keypad once. Within four to eight seconds after the first activation the transmitter input must be tripped and restored a second time. The keypad beeps twice. The keypad displays the “learned” transmitter identification number (ID). To accept this number, press the CMD key. ID: _ _ _ _ _ _ _ Select NO to manually enter the transmitter identification number. At ID: _ _ _ _ _ _ _, enter the seven‑digit transmitter number printed under the bar code on the label attached to your Ademco transmitter. Press CMD to accept the number. Note: When programming a 5804BD, you must manually enter the Transmitter ID Number. INPUT NO: _ TRANSMITTER INPUT NUMBER Enter a number (1 to 4) to identify the transmitter input zone. When the transmitter ID is “learned,” the keypad displays the zone input number. Refer to the Ademco transmitter installation instructions for zone input information. Default is 1. Press the CMD key to accept the number. The display returns to ZONE NO for programming the next transmitter. ALREADY ZONE: XX TRANSMITTER ALREADY LEARNED This display indicates the transmitter has previously been learned as a zone and continuously displays until the Back Arrow or CMD key is pressed. Pressing the Back Arrow key returns programming to TRANSMIT NOW to allow a different transmitter to be learned. Pressing the CMD key returns programming to ZONE NO. PANEL ADDRESS ZONE NUMBERS XT30/XT50 SERIES XR150/XR550 SERIES 1 11 to 14 11 to 14 2 21 to 24 21 to 24 3 31 to 34 31 to 34 4 41 to 44 41 to 44 5 51 to 54 51 to 54 6 61 to 64 61 to 64 7 71 to 74 71 to 74 8 81 to 84 81 to 84 738A ADDRESS XR150/XR550 SERIES LX‑BUS PANEL ZONE RANGE LX‑BUS 1 LX‑BUS 2 LX‑BUS 3 LX‑BUS
4 LX‑BUS 5
Table 1: Keypad Bus Addresses Table 2: LX‑Bus Addresses
4 738A INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS Exit Programming Remove the jumper from the PROGRAM header to exit 738A programming mode. Place the jumper over one pin for future use. Remove the Model 330 cable and the DMP keypad from the PROG header. After exiting the programming mode, all zone states report to the panel as normal. Always test and verify all zones for proper communication. ADDITIONAL INFORMATION Wiring Specifications The maximum wire distance between the Ademco™ wireless receiver and the module is 3 feet. Refer to the following LX‑Bus and Keypad bus wiring specifications. DMP recommends using 18 or 22 AWG for all LX‑Bus and Keypad Bus connections. The maximum wire distance between any module and the DMP Keypad Bus or LX‑Bus circuit is 1,000 feet. To increase the wiring distance, install an auxiliary power supply, such as a DMP Model 505‑12. Maximum voltage drop between a panel or auxiliary power supply and any device is 2.0 VDC. If the voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit. To maintain auxiliary power integrity when using 22‑gauge wire on Keypad Bus circuits, do not exceed 500 feet. When using 18‑gauge wire, do not exceed 1,000 feet. Maximum distance for any bus circuit is 2,500 feet regardless of wire gauge. Each 2,500 foot bus circuit supports a maximum of 40 LX‑Bus devices. For additional information refer to the LX‑Bus/Keypad Bus Wiring Application Note (LT‑2031) and the 710 Bus Splitter/ Repeater Module Installation Guide (LT‑0310). Keypad and LX‑Bus Connection For simple installation, the module connects to the panel 4‑wire keypad data bus. The module can also connect to the on‑board LX‑Bus of an XR150/XR550 Series panel. XR150/XR550 Series Connect the module directly to the Keypad Bus or the LX‑Bus (LX500‑LX900) connectors on the panel. Note: When programming module zones on the LX‑Bus select NO at the Wireless option in the Zone Information section of panel programming. 738A LED Operation The green LED on the module indicates data transmission to the panel.
- On —There are no transmitters programmed
- Off—The module is not being programmed or it is not responding to the panel
- Flashing—The module is transmitting data to the panel or it is being programmed LED LED CONDITION SOUNDER SYSTEM STATUS Red ON Steady
2 Beeps Armed Away
3 Beeps Armed Stay or Instant
Steady Armed, Burglary Alarm Green ON Steady 1 Beep Disarmed, Ready to Arm Flashing Silent Disarmed, Not Ready to Arm Table 3: LED and Sounder Operation
738A INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 5 ADEMCO COMPATIBILITY Compatible Ademco Wireless Transmitters and Receivers Table 4 and Table 5 list current Ademco transmitters and receivers that have been tested by DMP and are compatible with the module. Other Ademco products have not been evaluated by DMP. The 738A module has not been tested by UL. The module supports up to 32 wireless zones. The module can deliver all 32 zones to a DMP panel regardless of the number of zones assigned by the Ademco wireless receiver model number. For example, a Model 5881ENL 8‑Zone Receiver delivers 32 wireless zones to the module. RECEIVER MODEL NUMBER XT30/XT50 SERIES AND XR150/XR550 SERIES 5881ENL 8‑Zone Receiver 32 Zones 5881ENM 16 Zone Receiver 32 Zones 5881ENH 64‑Zone Receiver 32 Zones Note: Dip switches on the 5881 series receiver must be set to zero. Table 4: Ademco Receivers SUPERVISED ADEMCO TYPE UNSUPERVISED ADEMCO TYPE 5802MN Miniature Panic Button BR or UR 5802 Panic Button BR
5816 Window/Door RF 5803 3‑Button BR
5817 3‑Zone RF 5804 4‑Button BR
5890 Motion Detector RF 5804BD 4‑Button * BR
- Note: For use with XT30/XT50 Series panels. * Note: For use with XT30/XT50 Series panels. Table 5: Ademco Transmitters Ademco 5800TM Transmitter Module The 738A supports the Armed, Alarm, and Ready to Arm status LEDs on an Ademco 5804BD. This requires connecting an Ademco 5800TM to an XT30/XT50 panel. When a 5800TM is connected as shown in Figure 4. the panel Armed, Alarm, and Ready to Arm status displays on the Ademco 5804BD Wireless Key LED and sounder. Table 3 describes the LED and sounder operation. Refer to the Ademco 5804BD Installation Instructions for proper button operation. Ademco 5804BD Panic Buttons Use 5804BD buttons A and C to send a panic signal to the DMP panel. Press the A and C buttons at the same time for two seconds to send a Zone 19 Panic signal to the central station receiver. The zone name information sent to the receiver contains the first address number that the module is answering. Note: For use with XT30/XT50 panels. When programming the 5804BD into the panel, you must manually enter the transmitter ID number in ZONE INFORMATION.
Designed, engineered, and manufactured in Springfield, MO using U.S. and global components. LT-0377 21523 738A ADEMCO INTERFACE MODULE Specifications Primary Power 12 VDC Current Draw 75 mA Dimensions 5.50” W x 3.00” H x 0.75” D 13.97 cm W x 7.62 cm x H x 1.91 cm D Accessories Model 300 4‑Wire Harness Compatibility XR150/XR550 Series panels XT30/XT50 Series panels with firmware Version 101 or higher Certifications FCC Part 15 MODEL 738A INTRUSIO N • FIR E • ACCES S • NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803‑8877 800.641.4282 | DMP.com FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help.