KMP_5600C_D01 Page 1 of 3

5600 Series

10A Current Sensing Transformers www.murata-ps.com www.murata.com For full details go to www.murata-ps.com/rohs

FEATURES

„RoHS compliant „50, 100, 200 & 300 turn variants „Primary current rating 10A „20kHz-200kHz frequency range „Centre tapped variants available

DESCRIPTION

The 5600 series of current sense transformers are designed to monitor AC currents. They can be used for high frequency current sensing, for example in switched-mode power supplies, motor control and electronic lighting ballasts. SELECTION GUIDE Order Code Number of Turns Inductance Min. DC Resistance Terminating Resistance to Produce 1VOUT/1AIN ±1Turn Pins 1&3 Pins 1&3, Ω Ω 56050C 50 4.5mH @1V, 50kHz 0.133 - 0.199 50 56100C 100 18mH @1V, 50kHz 0.93 - 1.40 100 56200C 200 72mH @1V, 10kHz 1.87 - 2.81 200 56300C 300 160mH @1V, 10kHz 5.73 - 8.59 300 56T100C 100CT 18mH @1V, 50kHz 0.93 - 1.40 100 56T200C 200CT 72mH @1V, 10kHz 1.87 - 2.81 200 56T300C 300CT 160mH @1V, 10kHz 5.73 - 8.59 300 ABSOLUTE MAXIMUM RATINGS Operating free air temperature range -40°C to 85°C Storage temperature range -40°C to 125°C SOLDERING INFORMATION1 Peak wave solder temperature 300˚C for 10 seconds Pin finish Tin TECHNICAL NOTES ISOLATION VOLTAGE All 5600 current sense transformers are tested at 500Vdc for a minimum of 1 second during our standard test procedure. In addition, as part of our qualification process carried out prior to product launch, the 5600 series demonstrated no isolation breakdown at 10kVdc or 6kVac with a bare conductor as the primary winding. Whilst this does not imply these parts are designed for environments where such high voltages may be present, it does demonstrate the level of isolation voltage these products are able to withstand. Full mains safety isolation can be achieved with appropriately insulated wire on the primary winding. Specifications typical at TA = 25°C 1 For further information, please visit www.murata-ps.com/rohs

KMP_5600C_D01 Page 2 of 3 10A Current Sensing Transformers www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS 16.79 (0.661) 8.89 (0.350) 4.0 (0.157) 6.35 (0.250) 12.70 (0.500) Ø5.00 (0.197) Ø0.79±0.05 (0.031±0.002) 1.02 (0.040)12 * 3 20.19 (0.795) XYYWW 56300C Package weight: 5.7g Typ. *Pin 2 is fitted on 56TXXXC variants only. Arrow designates winding direction referenced to inner core surface. Unless otherwise stated, all dimensions in mm (inches) ± 0.25 (0.010). Tube length: 475±2 [18.701±0.079] Unless otherwise stated, all dimensions in mm (inches) ± 0.25 (0.010). Tube quantity: 25 Tube material: Antistatic coated clear PVC 6.35 (0.250) 12.70 (0.500) 0.10 (0.004) x3 HOLES Ø0.059 (1.50) Ø0.065 (1.65) Unless otherwise stated, all dimensions in mm (inches) ± 0.25 (0.010). Schematic 11.20 (0.441) 7.00 (0.276) 30.00 (1.181) 22.20 (0.874)

KMP_5600C_D01 Page 3 of 3 10A Current Sensing Transformers www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2021 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:

  • Aircraft equipment
  • Aerospace equipment
  • Undersea equipment
  • Power plant control equipment
  • Medical equipment
  • Transportation equipment ( automobiles, trains, ships, etc.)
  • Traffic signal equipment
  • Disaster prevention / crime prevention equipment
  • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.