55AC1111 MACOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MI L-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Wire & Cable

501 Oakside Avenue

Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 SPECIFICATION CONTROL DRAWING 55AC1111 Title ONE CONDUCTOR CABLE, SHIELDED, JACKETED, 600 VOLT Date 7-18-03 Revision A This specification sheet forms a part of the latest issue of Raychem Specification 55A. COMPONENT WIRE – 55A0111 SHIELD – TIN-COAT ED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE CABLE CONSTRUCTION DETAILS JACKET THICKNESS (in.) OUTSIDE DIAMETER (in.) PART NUMBER CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) MINIMUM NOMINAL NOMINAL MAXIMUM MAXIMUM WEIGHT (lb/1000 ft) CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150°C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 ± 3°C for 7 hours BLOCKING: 200 ± 3°C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz FLAMMABILITY: Procedure 1, 3 seconds (maximum); 3 inches (maximum); no flaming of facial tissue JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in² (minimum) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 200 ± 3°C for 168 hours LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours SHIELD COVERAGE: 90% (minimum) VOLTAGE WITHSTAND TEST (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "*" in the part numbers above shall be replaced by a color code designator with a dash separating the component wire color from the jacket color. / Example: AWG 22, white component wire; white jacket: 55AC1111-22-9-9 NOTE: Nominal values are for information only. Nominal values are not requirements. Page 1 of 1