55A1842 BRIGHT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

55A1842-26-* 55A1842-24-* 55A1842-22-* 55A1842-20-* 55A1842-18-* 55A1842-16-* 55A1842-14-* 55A1842-12-* 55A1842-10-* 55A1842- 8-* 55A1842- 6-* 55A1842- 4-* TITLE Page 1 of 1 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. This specification sheet forms a part of the latest issue of Raychem Specification 55A. 55A1842 COMPONENT WIRE - 55A0812 SHIELD - SILVER-COATED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE CABLE RATINGS AND ADDITIONAL REQUIREMENTS NOTE: Nominal values are for information only. Nominal values are not requirements. TEMPERATURE RATING: 200°C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 ± 3°C for 7 hours BLOCKING: 200 ± 3°C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz FLAMMABILITY: Procedure 1, 3 seconds (maximum); 3 in. (maximum); no flaming of facial tissue JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in² (minimum) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 230 ± 3°C for 500 hours LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST(Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "*" in the part numbers above shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the jacket color. Colors shown do not necessarily reflect the sequence of manufacturing. 1/ Example: AWG 20, brown, red, orange and yellow component wires; white jacket: PART NUMBER OUTSIDE DIAMETER (inches) NOMINALMINIMUM CABLE CONSTRUCTION DETAILS CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) JACKET THICKNESS (inches) NOMINAL MAXIMUM MAXIMUM WEIGHT (lbs/1000 ft.) 14.7 18.0 22.5 30.0 42.2 51.4 74.0 104. 162. 305. 455. 743. .150 .165 .179 .202 .237 .259 .308 .357 .430 .613 .753 .960 .130 .142 .154 .173 .202 .221 .262 .304 .365 .520 .637 .812 .006 .006 .006 .006 .006 .007 .007 .007 .008 .009 .012 .016 .008 .008 .008 .008 .008 .009 .009 .009 .010 .011 .014 .018 SPECIFICATION CONTROL DRAWING FOUR CONDUCTOR CABLE, RADIATION-CROSSLINKED, MODIFIED ETFE INSULATED, SHIELDED, JACKETED, NORMAL WEIGHT, 600 VOLT 02-26-04 Date Revision R Wire & Cable

501 Oakside Avenue

Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCH EM PART NUMBER, SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any sp ecification, without notification to Buyer. Users should evaluate the suitability of this product for their application. Specifications are subject to change without noti ce. B