55A1112 TEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.Page 1 of 1 Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable

501 Oakside Avenue

Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2008-2013 Tyco Electronics Corporation. All rights reserved. SPECIFICATION CONTROL DRAWING 55A1112 ONE CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 6-25-13 F This specification sheet forms a part of the latest issue of Raychem Specification 55A. JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE COMPONENT WIRE - 55A0112 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TITLE Date Revision SHIELD - SILVER-COATED COPPER CABLE CONSTRUCTION DETAILS PART NUMBER CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) JACKET THICKNESS (inches) OUTSIDE DIAMETER (inches) MAXIMUM WEIGHT (lbs/1000 ft.)MINIMUM NOMINAL NOMINAL MAXIMUM TEMPERATURE RATING: 200°C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 ± 3°C for 7 hours BLOCKING: 200 ± 3°C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz FLAMMABILITY (Procedure 1): 3 seconds (maximum); 3 in. (maximum); no flaming of facial tissue JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in² (minimum) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) NOTE: Nominal values are for information only. Nominal values are not requirements. LIFE CYCLE: 230 ± 3°C for 500 hours LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The “*” in the part numbers above shall be replaced by color code designators with a dash separating the component wire color from the jacket color. 1/ Example: AWG 20, black component wire; white jacket: 55A1112-20-0-9