Features

– Connections for eight digital actuators – Connection of actuators in 2, 3, and 4-wire technology – Nominal current of each output: 0.5 A – Total current of the terminal: 4 A – Short-circuit and overload protected outputs – Diagnostic and status indicators – Approved for use within a safety-related segment circuit (observe the notes on page 8) /G34 /G78 This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page: Inline terminal with eight digital outputs

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 2 2O r d e r i n g d a t a Products Description Type Order No. Pcs./Pkt. Terminal with eight digital outputs; complete with accessories (connectors consecutively numbered and labeling fields); transmission speed of 500 kbps IB IL 24 DO 8-PAC 2861289 1 Terminal with eight digital outputs; complete with accessories (connectors not consecutively numbered and la - beling fields); transmission speed of 500 kbps IB IL 24 DO 8-PAC/SN 2862945 1 Terminal with eight digital outputs; without accessories; transmission speed of 500 kbps IB IL 24 DO 8 2726269 1 Terminal with eight digital outputs; complete with accessories (connectors consecutively numbered and labeling fields); transmission speed of 2 Mbps IB IL 24 DO 8-2MBD-PAC 2861687 1 Terminal with eight digital outputs; complete with accessories (connectors not consecutively numbered and la - beling fields); transmission speed of 2 Mbps IB IL 24 DO 8-2MBD-PAC/SN 2878227 1 Terminal with eight digital outputs; without accessories; transmission speed of 2 Mbps IB IL 24 DO 8-2MBD 2819037 1 One of the listed connectors is needed for the complete fitting of the IB IL 24 DO 8 and IB IL 24 DO 8-2MBD terminals. Accessories Description Type Order No. Pcs./Pkt. Connector with eight spring-cage connections (green, w/o color print) IB IL SCN-8 2726337 10 Connector with eight spring-cage connections (green, with color print) IB IL SCN-8-CP 2727608 10 Connector set with 32 spring-cage connections (green, w/o color print) IB IL DI/DO 8-PLSET 2860950 1 Connector set with 32 spring-cage connections (green, with color print) IB IL DI/DO 8-PLSET/CP 2860963 1 Documentation Description Type Order No. Pcs./Pkt. "Configuring and installing the INTERBUS Inline product range" user manual IB IL SYS PRO UM E 2743048 1 "Automation terminals of the Inline product range" user manual IL SYS INST UM E 2698737 1 "INTERBUS addressing" data sheet DB GB IBS SYS ADDRESS – – "Safety-related segment circuit" application note AH EN IL SAFE – –

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 3

3 Technical data

Housing dimensions (width x height x depth) 48.8 mm x 119.8 mm x 71.5 mm Weight 130 g (without connectors) Operating mode Process data mode with 1 byte Connection method for actuators 2, 3, and 4-wire technology Permissible temperature (operation) -25°C to +55°C Permissible temperature (storage/transport) -25°C to +85°C Permissible humidity (operation) 75% on average, 85% occasionally Permissible humidity (operation/storage/transport) 10% to 95% according to DIN EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kPa to 106 kPa (up to 3000 m above sea level) Degree of protection IP20 according to IEC 60529 Protection class Class 3, according to EN 61131-2, IEC 61131-2 Connection data for connectors Connection method Spring-cage terminals Conductor cross-section 0.08 mm2 to 1.5 mm2 (solid or stranded), 28 - 16 AWG Interface Local bus Via data routing Transmission speed IB IL 24 DO 8 500 kbps IB IL 24 DO 8-PAC 500 kbps IB IL 24 DO 8-PAC/SN 500 kbps IB IL DO 8-2MBD 2 Mbps IB IL 24 DO 8-2MBD-PAC 2 Mbps IB IL 24 DO 8-2MBD-PAC/SN 2 Mbps Supply of the module electronics and I/O through the bus terminal/power terminal Connection method Via potential routing Power consumption 500 kbps 2 Mbps Communications power 7.5 V 7.5 V Current consumption from the local bus 60 mA, maximum 85 mA, maximum Power consumption from the local bus 0.45 W, maximum 0.64 W, maximum Segment supply voltage US 24 V DC (nominal value) 24 V DC (nominal value) Nominal current consumption at Us 4 A (8 x 0.5 A), maximum 4 A (8 x 0.5 A), maximum Digital outputs Number 8 Nominal output voltage UOUT 24 V DC Differential voltage for Inom ≤ 1 V Nominal current Inom per channel 0.5 A Tolerance of the nominal current +10% Total current 4 A Protection Short circuit; overload Nominal load Ohmic 48 Ω / 12 W Lamp 12 W Inductive 12 VA (1.2 H, 50 Ω) Channels are thermally coupled in groups of four, i.e., an error in one channel can affect the other channels.

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 4 Signal delay upon power up of: Nominal ohmic load 100 µs, typical Nominal lamp load 100 ms, typical (with switching frequencies up to 8Hz; above this frequency the lamp load responds like an ohmic load) Nominal inductive load 100 ms, typical (1.2 H, 50 Ω) Signal delay upon power down of: Nominal ohmic load 1 ms, typical Nominal lamp load 1 ms, typical Nominal inductive load 50 ms, typical (1.2 H, 50 Ω) Switching frequency with: Nominal ohmic load 300 Hz, maximum Nominal lamp load 300 Hz, maximum Nominal inductive load 0.5 Hz, maximum (1.2 H, 48 Ω) Overload response: Auto restart Response time with ohmic overload (12 Ω) 3 s, approximately Restart frequency with ohmic overload 400 Hz, approximately Restart frequency with lamp overload 400 Hz, approximately Response with inductive overload Output may be damaged Response time in the event of a short circuit 400 ms, approximately Reverse voltage protection against short pulses Protected against reverse voltages Resistance to permanently applied reverse voltages Up to 2 A DC Resistance to polarity reversal of the supply voltage Pro tective elements in the bus terminal or power terminal Resistance to permanently applied surge voltage No Validity of output data after connecting the 24 V voltage supply (power up) 5 ms, typical Response upon power down The output follows the supply voltage without delay. Limitation of the voltage induced on circuit interruption -15 V ≤ Udemag ≤ -46 V (Udemag = demagnetization voltage) Single maximum energy in free running 400 mJ, maximum Protective circuit type Integrated 45 V Zener diode in the output chip Overcurrent shutdown 0.7 A, minimum Output current when switched off 300 µA, maximum Output voltage when switched off 2 V, maximum Output current with ground connection interrupt 25 mA, maximum Switching power with ground connection interrupt 100 mW at 1 kΩ load resistance, typical Inrush current with lamp load 1.5 A for 20 ms, maximum Digital outputs (continued) This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or computer system used. This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or computer system used. Output characteristic curve when switched on (typical) Output current (A) Differential output voltage (V) 0 0 0.1 0.04 0.2 0.08 0.3 0.12 0.4 0.16 0.5 0.20

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 5 Power dissipation Formula to calculate the power dissipation of the electronics 500 kbps

2 Mbps

Where: PEL Total power dissipation in the terminal n Index of the number of set outputs n = 1 to 8 ILn load current of output n Power dissipation of the housing PHOU 2.7 W, maximum (within the permissible operating temperature) P = 0.19 W + x 0.40EL Ln /c83/c87(0.10W+I ) n=1 /G50 /G45 /G4C /G20 /G3D /G20 /G30 /G2E /G34 /G36 /G20 /G57 /G20 /G2B /G20 /G53 /G20 /G20 /G28 /G30 /G2E /G31 /G30 /G20 /G57 /G20 /G2B /G20 /G49 /G4C /G6E /G32 /G20 /G78 /G20 /G30 /G2E /G34 /G30 /G20 /G57 /G29 /G6E /G20 /G3D /G20 /G31 /G38 Limitation of simultaneity, derating Derating No limitation of simultaneity, no derating Protective equipment Overload/short circuit in the segment circuit Electronic; with two 4-channel drivers Surge voltage Protective elements of the power terminal Protection up to 33 V DC Polarity reversal of the supply voltage Protective elements of the power terminal The supply voltage must be protected. The power supply unit should be able to supply four times (400%) the nominal current of the fuse. Reverse voltage Protected against reverse voltages up to 2 A DC Electrical isolation/isolation of the voltage areas Common potentials The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate potentials in the system consisting of bus terminal/power terminal and I/O terminal Test distance Test voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 7.5 V supply (bus logic) / 24 V supply (I/O) 500 V AC, 50 Hz, 1 min. 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min. To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital output terminal described here via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted. (See also user manual.) Error messages to the higher-level control or computer system Short circuit/overload of an output Yes Operating voltage out of range No An error message is generated when an output is shorted and switched on. In addition, the diagnostic LED (D) flashes on the terminal at 2Hz (medium) under these conditions. Approvals For the latest approvals, please visit www.phoenixcontact.net/catalog.

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 6

4 Internal basic circuit diagram

Figure 1 Internal wiring of the terminal points Key: /G2B /G32 /G34 /G20 /G56 /G20 /G28 /G55 /G4D /G29 /G2B /G32 /G34 /G20 /G56 /G20 /G28 /G55 /G53 /G29 /G4C /G6F /G63 /G61 /G6C /G20 /G62 /G75 /G73 /G55 /G4C /G4F /G50 /G43 /G32 /G34 /G32 /G32 /G32 /G32 /G32 /G32 /G32 /G34 /G34 /G34 /G35 /G35 /G35 /G38 /G43 /G30 /G30 /G33 Protocol chip (bus logic including voltage conditioning) LED Optocoupler Transistor Digital output Electrically isolated area Other symbols used are explained in the IL SYS INST UM E user manual. OPC

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 7

5 Local diagnostic and status indica -

tors and terminal point assignment

5.1 Local diagnostic and status indicators

Figure 2 Local diagnostic and status indicators

5.2 Function identification

2 Mbps: white stripe in the vicinity of the D LED

5.3 Terminal point assignment for each connector

Figure 3 Terminal point numbering: individual connec - tors (A) and connector sets (B) Des. Color Meaning D Green Diagnostics 1, 2 Yellow Status indicators for the outputs /G31 /G32 /G44 /G44 /G4F /G20 /G38 /G31 /G32 /G31 /G32 /G31 /G32 /G35 /G35 /G35 /G38 /G43 /G30 /G30 /G32 A –U s i n g t h e I B IL 24 DO 8-PAC/SN or IB IL 24 DO 8-2MBD-PAC/SN with the supplied connectors – Using individual connectors (IB IL SCN-8 or IB IL SCN-8-CP) B –U s i n g t h e I B IL 24 DO 8-PAC or IB IL 24 DO 8-2MBD-PAC with the original connector set – Using a connector set (IB IL DI/DO 8-PLSET or IB IL DI/DO 8-PLSET/CP) Terminal point Assignment x.1 Signal output (OUT) x.2 Segment voltage US for 4-wire termination Measuring points for the supply voltage x.3 Ground contact (GND) for 2, 3, and 4-wire termination x.4 FE connection for 3 and 4-wire termination x x xx 5558A010 1.1 1.2 2.1 2.2 1.3 2.3 1.4 2.4 AB 1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4 3.1 3.2 3.3 3.4 4.1 4.2 4.3 4.4 5.1 5.2 5.3 5.4 6.1 6.2 6.3 6.4 7.1 7.2 7.3 7.4 8.1 8.2 8.3 8.4 1.1 1.2 1.3 1.4 8.1 8.3 8.4 8.2

IB IL 24 DO 8 ... 5558_en_08 PHOENIX CONTACT 8

6 Connection example

Figure 4 Typical connection of actuators A 4-wire termination B 3-wire termination The numbers above the module illustration identify the con- nector slots.

7 Notes on using the terminals within

a safety-related segment circuit The terminals of the following hardware version and later (listed below) are approved for use within a safety-related segment circuit. Figure 5 Labeling on an Inline terminal When connecting the actuators observe the as- signment of the terminal points to the process data (see page 9). /G31 /G32 /G31 /G32 /G33 /G34 /G31 /G32 /G33 /G34 /G31 /G32 /G31 /G32 /G33 /G34 /G31 /G32 /G33 /G34 /G31 /G32 /G31 /G32 /G33 /G34 /G31 /G32 /G33 /G34 /G31 /G32 /G31 /G32 /G33 /G34 /G31 /G32 /G33 /G34 /G31 /G32 /G44 /G44 /G4F /G20 /G38 /G31 /G32 /G31 /G32 /G31 /G32 /G35 /G35 /G35 /G38 /G32 /G30 /G30 /G34 /G31 /G32 /G33 /G34 /G2B /G32 /G34 /G20 /G56 /G4F /G55 /G54 /G41 /G4F /G55 /G54 /G42 Order No. Order designation Hardware version

2861289 IB IL 24 DO 8-PAC 05

2862945 IB IL 24 DO 8-PAC/SN 07

2726269 IB IL 24 DO 8 05

2861687 IB IL 24 DO 8-2MBD-PAC 04

2878227 IB IL 24 DO 8-2MBD-PAC/SN 04

2819037 IB IL DO 8-2MBD 04

The hardware version is marked on the side of the housing of every terminal (1 in Figure 5). The instructions in the current documentation for the safety terminal used and from the AH EN IL SAFE application note must be ob- served to ensure that operation of the safety-re- lated segment circuit is not adversely affected. The latest documentation can be downloaded at www.phoenixcontact.net/catalog. /G49 /G4E /G54 /G45 /G52 /G42 /G55 /G53 /G49 /G42 /G20 /G20 /G49 /G4C /G20 /G20 /G32 /G34 /G20 /G20 /G44 /G4F /G20 /G38 /G4F /G72 /G64 /G65 /G72 /G2D /G4E /G6F /G2E /G3A /G20 /G20 /G32 /G37 /G32 /G36 /G32 /G36 /G39 /G4D /G6F /G64 /G75 /G6C /G65 /G2D /G49 /G44 /G3A /G20 /G58 /G58 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G48 /G57 /G2F /G53 /G57 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G20 /G30 /G35 /G2F /G2D /G20 /G31 /G35 /G35 /G35 /G38 /G41 /G30 /G30 /G38

IB IL 24 DO 8 ... 5558_en_08 9PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com

8 Programming data/

8.1 Local bus (INTERBUS)

8.2 Other bus systems

9 Process data

Assignment of the terminal points to OUT process data The following table applies to the IB IL 24 DO 8-PAC and IB IL 24 DO 8-2MBD-PAC terminals with the original con- nector set and when using the IB IL DI/DO 8-PLSET and IB IL DI/DO 8-PLSET/CP connector sets (see also Figure 3 on page 7, detail B). The following table applies to the IB IL 24 DO 8-PAC/SN and IB IL 24 DO 8-2MBD-PAC/SN terminals with the origi- nal connector set and when using the IB IL SCN-8 or IB IL SCN-8-CP connectors (see also Figure 3 on page 7, detail A). ID code BDhex (189dec) Length code 81hex Process data channel 8 bits Input address area 0 bytes Output address area 1 byte Parameter channel (PCP) 0 bytes Register length (bus) 1 byte For the programming data/configuration data of other bus systems, please refer to the corre sponding electronic device data sheet (GSD, EDS). For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer sys tem, please refer to the DB GB IBS SYS ADDRESS data sheet. (Byte.bit) view Byte Byte 0 Bit 7 6 5 4 3 2 1 0 Assign- ment Slot 4 3 2 1 Terminal point (signal) Terminal point (+24 V) Terminal point (GND) Terminal point (FE) Status in- dicator Slot 4 3 2 1 LED 2 1 2 1 2 1 2 1 (Byte.bit) view Byte Byte 0 Bit 7 6 5 4 3 2 1 0 Assign- ment Slot 4 3 2 1 Terminal point (signal) Terminal point (+24 V) Terminal point (GND) Terminal point (FE) Status in- dicator Slot 4 3 2 1 LED 2 1 2 1 2 1 2 1