Technical data subject to change © B&K Precision Corp. 2020 www.bkprecision.com Digital Multimeters 5½ & 6½ Digit 5490C Series The 5490C Series 5½ and 6½-digit bench multimeters are designed for accuracy, repeatability and ease-of-use. A wide measurement range with speeds up to 1000 readings per second, and a basic DCV accuracy up to 35 ppm deliver stable measurement results quickly and accurately. These general purpose meters are well suited for demanding engineering, production and service applications. The multimeters feature simple and intuitive switching between the 12 measurement functions and display modes for a variety of test setups. Display modes include bar meter, trend chart, and histogram which can be combined with statistics or math functions. The dual measurement feature enables the simultaneous display of 2 measurements, e.g. AC voltage and frequency. Additionally, Limit mode and Probe hold mode allow users to conveniently verify and compare readings. Features and benefits n 12 measurement functions: DCV, ACV, DCI, ACI, 2 and 4-wire resistance, capacitance, frequency, diode, temperature, continuity test, DCV Ratio n High-contrast 4.3-inch full color LCD n Histogram, bar meter, and trend chart offer a variety of data analysis options n Accurate frequency measurements to 1 MHz n Display Min, Max, Peak-Peak, Average, Standard Deviation statistics simultaneously n Null, dB, dB, %, mx+b, and run/stop math functions n Internal storage buffer holds 10,000 readings n Measurement speed up to 1000 readings/s n 35 ppm basic DC voltage accuracy n 2-wire and 4-wire resistance measurements down to 10 Ω n Dual measurement display n Temperature measurement capability using a Pt100 or 5 kΩ thermistor probe n Rack mount kit option (RK02) n Rear input terminals for rack use (6½-digit model only) n Standard USB (USBTMC-compliant), RS232, and LAN interfaces, GPIB option n Real-time clock/calendar to set/read time and date Model 5492C 5492CGPIB 5493C 5493CGPIB Displayed Digits 5½ 6½ DC Voltage basic accuracy 0.010% (100 ppm) 0.0035% (35 ppm) Rear input terminals -- √ For remote communication, this series includes standard LAN, USB (USBTMC-compliant) and RS232 interfaces, as well as a GPIB option. A LabVIEWTM driver is provided to simplify system integration and instrument control. The front panel USB host port can be used for transferring screen captures and measurement data, logged with date and time stamp, from the multimeter's internal memory to a computer. * GPIB model option USB LAN RS232 GPIB* Operating software The provided operating software supports remote instrument control, live measurement monitoring, and data logging.
www.bkprecision.com Front panel Rear panel USB host Save and recall settings, transfer screen captures, export measurement data files Function keys Quickly cycle between different measurement modes Remote interfaces LAN, USB (USBTMC-compliant) and RS232 interfaces standard Optional GPIB interface Models 5492CGPIB and 5493CGPIB External trigger Trigger input to synchronize with other events and instruments Rear input terminals 6½-digit models only LCD display 4.3-inch, high contrast, adjustable brightness Input terminals
www.bkprecision.com Powerful measurement tools Multiple measurement and display options DC Voltage DC Current DC Resistance AC Voltage AC Current Capacitance Frequency Min/Max measurement capabilities 5492C/5492CGPIB 5493C/5493CGPIB 1 µ 1 1 M 1 µV 1000 V0.1 µV 1 nA 10 A0.1 nA 100 MΩ 10 µΩ
750 V1 mV
1 nA 10 A0.1 nA 10 mF 0.1 pF 3.3 Hz
1 MHz
2.2 Hz 1 p Simultaneously display multiple measurements such as frequency and AC voltage. Dual measurement display Bar meter with limit mode Set upper and lower limit levels with PASS/FAIL counter and indicators. Displays the ratio between two separate DC voltage measurements within ±12 Volts. This function is useful to quickly verify the difference between input and output magnitudes of low voltage circuits. DC voltage ratio measurement Trend chart Trend chart displays live data in graphical form. In addition to statistical data and limit test mode, this series is capable of Null, dB, dBm, mX+b, run/stop, and percent calculation functions. Versatile math functions Histogram with statistics Histogram display mode to view distribution of measurement data. n Minimum, maximum, peak-to-peak, average, standard deviation n Reading buffer holds 10,000 data samples Statistics display Use probe hold mode to quickly compare a series of readings. Stable readings are captured and added to a list of up to eight measurements. Probe hold mode
www.bkprecision.com Specifications - 5492C / 5492CGPIB Specifications are based on the following conditions: - One year calibration cycle - Calibration temperature TCAL = 23 °C - Accuracy specifications: ± (% of reading + % of range), valid for TCAL ±5 ºC - For DC: The technical specifications are valid after a warm-up time of 60 minutes, with the integration time set to 10 or 100 NPLC, and auto zero enabled. - For AC: The technical specifications are valid after a warm-up time of 60 minutes, slow AC filtering enabled, using a sine wave input signal. Range(1) Resolution Full Scale Reading Accuracy (1 year) 100 mV 1 µV 119.999 mV 0.012 + 0.008 1 V 10 µV 1.19999 V 0.010 + 0.005 10 V 100 µV 11.9999 V 0.010 + 0.005 100 V 1 mV 119.999 V 0.010 + 0.005 1000 V 10 mV 1050.00 V 0.010 + 0.005 (1) 20% overrange on all ranges except 1000 V can only test 5% overrange. DC Current Range Burden Voltage Resolution Full Scale Reading Accuracy (1 year) 100 µA < 0.011 V 1 nA 119.999 µA 0.050 + 0.008 1 mA < 0.11 V 10 nA 1.19999 mA 0.050 + 0.005 100 mA < 0.5 V 1 µA 119.999 mA 0.050 + 0.005 1 A < 0.7 V 10 µA 1.19999 A 0.100 + 0.010 3 A < 2.0 V 10 µA 3.1500 A 0.150 + 0.020 10 A < 0.5 V 100 µA 11.9999 A 0.200 + 0.010 Range(3) Test Current Resolution Full Scale Reading Accuracy (1 year) 10 Ω 10 mA 0.1 mΩ 11.9999 Ω 0.050 + 0.008 100 Ω 10 mA 1 mΩ 119.999 Ω 0.040 + 0.005 1 kΩ 1 mA 10 mΩ 1.19999 kΩ 0.030 + 0.004 10 kΩ 100 µA 0.1 mΩ 11.9999 kΩ 0.030 + 0.004 100 kΩ(4) 50 µA 1 Ω 119.999 kΩ 0.030 + 0.004 1 MΩ 5 µA 10 Ω 1.19999 MΩ 0.030 + 0.004 10 MΩ 500 nA 100 Ω 11.9999 MΩ 0.100 + 0.004 100 MΩ 500 nA || 10 MΩ 1 kΩ 119.999 MΩ 1.000 + 0.010 DC Resistance(2) (2) Specifications apply to 2-wire and 4-wire resistance measurements using NULL for offset. Without NULL, add 0.2 Ω additional error for 2-wire measurements. (3) 20% overrange on all ranges (4) To eliminate noise interference, it is recommended to use shielded test cables for resistance measurements above 100 kΩ. DC Voltage Range(5) Test Current Full Scale Reading Accuracy (1 year) 1 nF 10 µA 1.19999 nF 1.0 + 0.5 10 nF 10 µA 11.9999 nF 0.5 + 0.1 100 nF 10 µA 119.999 nF 0.5 + 0.1 1 µF 100 µA 1.19999 µF 0.5 + 0.1 10 µF 100 µA 11.9999 µF 0.5 + 0.1 100 µF 1 mA 119.999 µF 0.5 + 0.1 1 mF 10 mA 1.19999 mF 0.5 + 0.1 10 mF 10 mA 11.9999 mF 1.0 + 0.50 Capacitance Frequency Range Resolution Full Scale Reading Accuracy (1 year) 3 Hz to 10 Hz 10 µHz 9.99999 Hz 0.050 + 50 10 Hz to 100 Hz 100 µHz 99.9999 Hz 0.010 + 10 100 Hz to 1 kHz 1 mHz 999.999 Hz 0.005 + 2 1 kHz to 10 kHz 10 mHz 9.99999 kHz 0.005 + 2 10 kHz to 100 kHz 0.1 Hz 99.9999 kHz 0.005 + 2 100 kHz to 300 kHz 1 Hz 300.000 kHz 0.005 + 2 300 kHz to 1 MHz (8) 1 Hz 999.999 kHz 0.005 + 2 Frequency(6)(7) (6) Applies to sine wave input and gate time set to 1 second. (7) For sine wave input larger than 100 mV. For a 10 mV to 100 mV input, multiply the % of reading error by 10. (8) For frequency measurements greater than 750 kHz, use manual ranges for best accuracy. (5) 20% overrange on all ranges.
www.bkprecision.com Specifications - 5492C / 5492CGPIB Range(3) Resolution Full Scale Reading 100 mV 1 µV 119.999 mV 1 V 10 µV 1.19999 V 10 V 100 µV 11.9999 V 100 V 1 mV 119.999 V 750 V(4) 10 mV 787.50 V (1) Valid for sine wave input > 0.3% of range and greater than 1 mVrms. (2) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (3) 20% overrange on all ranges except 750 V range can only test 5% overrange. (4) 750 V range is limited to 8 x 107 Volt-Hz. Range(7) Burden Voltage Resolution Full Scale Reading Accuracy (1 year)
3 Hz to 5 Hz 5 Hz to 20 Hz 20 Hz to 10 kHz
True RMS AC Current (5)(6) (5) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (6) Valid for sinewave input > 1% of range and greater than 10 µA AC. (7) 20% overrange on all ranges except 3 A range can only test 5% overrange. (8) 10 A range available on front panel only. Range Test Current Accuracy (1 year) Temperature Coefficient / °C 1 kΩ 1 mA 0.030 + 0.004 0.0010 + 0.0020 Continuity (9) Applicable to the voltage measured at the input terminal. A 1 mA test current is typical. Changes in the current source will cause variations in voltage drop across the diode junction. Range Test Current Accuracy (1 year) Temperature Coefficient / °C 5 V 1 mA 0.010 + 0.005(1) 0.0010 + 0.0020 Diode(9) Type Accuracy Pt100 (DIN / IEC 751) Probe accuracy + 0.05 °C 5 kΩ thermistor Probe accuracy + 0.10 °C Temperature Frequency Accuracy (1 Year) 3 Hz to 5 Hz 1.00 + 0.03 5 Hz to 20 Hz 0.38 + 0.03 20 Hz to 20 kHz 0.10 + 0.03 20 kHz to 50 kHz 0.15 + 0.05 50 kHz to 100 kHz 0.63 + 0.08 100 kHz to 300 kHz 4.00 + 0.50 True RMS AC Voltage(1)(2) 100 mV, 1 V, 10 V, 100 V, and 750 V ranges
www.bkprecision.com Specifications - 5493C / 5493CGPIB Specifications are based on the following conditions: - One year calibration cycle - Calibration temperature TCAL = 23 °C - Accuracy specifications: ± (% of reading + % of range), valid for TCAL ±5 ºC - All 24 hours accuracy specifications are typical - Add temperature coefficient for every ºC outside TCAL ±5 ºC - For DC: The technical specifications are valid after a warm-up time of 60 minutes, with the integration time set to 10 or 100 NPLC, and auto zero enabled. - For AC: The technical specifications are valid after a warm-up time of 60 minutes, slow AC filtering enabled, using a sine wave input signal. DC Voltage (1) 20% overrange on all ranges except 1000 V range which can only test 5% overrange. (2) Relative to calibration standards. DC Current (3) 10 A range available on front panel only. DC Resistance(4) (4) Specifications apply to 2-wire and 4-wire resistance measurements using NULL for offset. Without NULL, add 0.2 Ω additional error for 2-wire measurements. (5) 20% overrange on all ranges (6) To eliminate noise interference, it is recommended to use shielded test cables for resistance measurements above 100 kΩ. Range(1) Resolution Full Scale Reading Accuracy Temperature Coefficient / °C24 Hours(2) TCAL ± 1 °C
90 Days
TCAL ± 5 °C
1 Year
TCAL ± 5 °C Range Burden Voltage Resolution Full Scale Reading Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C Range(5) Test Current Resolution Full Scale Reading Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C
www.bkprecision.com Capacitance (1) 20% overrange on all ranges. Frequency 24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C Temperature Coefficient / °C Range(4) Resolution Full Scale Reading 100 mV 1 µV 119.9999 mV 1 V 10 µV 1.199999 V 10 V 100 µV 11.99999 V 100 V 1 mV 119.9999 V 750 V(5) 10 mV 787.500 V (2) Valid for sine wave input > 0.3% of range and greater than 1 mVrms. (3) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (4) 20% overrange on all ranges except 750 V range which can only test 5% overrange. (5) 750 V range is limited to 8 x 107 Volt-Hz. True RMS AC Voltage(2)(3) 100 mV, 1 V, 10 V, 100 V, and 750 V ranges Specifications - 5493C / 5493CGPIB Range Test Current Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1°C TCAL ± 5°C 1 year TCAL ± 5°C Continuity Range Test Current Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1°C TCAL ± 5°C 1 year TCAL ± 5°C Diode(6) (6) Applicable to the voltage measured at the input terminal. A 1 mA test current is typical. Changes in the current source will cause variations in voltage drop across the diode junction. Range(1) Full Scale Reading Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C
www.bkprecision.com Specifications - 5493C / 5493CGPIB Range(3), Burden Voltage Frequency Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C 100 µA, < 0.011 V 1 mA, < 0.11 V 10 mA, < 0.05 V 100 mA, < 0.5 V 1 A, < 0.7 V 3 A, < 2.0 V 10 A(4), < 0.5 V True RMS AC Current(1)(2) (1) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (2) Valid for sinewave input > 1% of range and greater than 10 µA AC. (3) 20% overrange on all ranges except 3 A range which can only test 5% overrange. (4) 10 A range available on front panel only. Frequency Range Accuracy Temperature Coefficient / °C24 Hours TCAL ± 1 °C TCAL ± 5 °C TCAL ± 5 °C 2 Hz to 10 Hz 0.1 0.100 0.100 0.0002 10 Hz to 100 Hz 0.030 0.030 0.030 0.0002 100 Hz to 1 kHz 0.003 0.008 0.010 0.0002 1 kHz to 300 kHz 0.002 0.006 0.010 0.0002 300 kHz to 1 MHz(7) 0.002 0.006 0.010 0.0002 Square wave(8) 0.001 0.006 0.010 0.0002 Frequency ±(% of reading)(5)(6) 100 mV, 1 V, 10 V, 100 V, and 750 V ranges (5) Applies for sine wave input and gate time set to 1 second. (6) For sine and square wave input larger than 100 mV. For a 10 mV to 100 mV input, multiply the % reading error by 10. (7) For frequency measurements greater than 750 kHz, use manual ranges for best accuracy. (8) Square input specified for 10 Hz to 300 kHz. Frequency 1 second 0.1 second 0.01 second 3 Hz to 40 Hz 0 0.200 0.200 40 Hz to 100 Hz 0 0.060 0.200 100 Hz to 1 kHz 0 0.020 0.200 1 Hz to 300 kHz 0 0.004 0.030 Square wave(8) 0 0 0 Additional gate time errors ±(% of reading) Type Accuracy Pt100 (DIN / IEC 751) Probe accuracy + 0.05 °C 5 kΩ thermistor Probe accuracy + 0.10 °C Temperature
www.bkprecision.comv091420 General AC Input 110 V/220 V ±10%, 50/60 Hz Power Consumption ≤ 30 VA I/O Interface RS232, USB host, USB (USBTMC-compliant) device, LAN, GPIB (5492CGPIB and 5493CGPIB only) Temperature Operating 32 °F to 104 °F (0 °C to 40 °C) Storage -40 ºF to 158 ºF (-40 ºC to 70 ºC) Humidity Indoor use, ≤ 95 % Safety EN 6110-1:2010, Low Voltage Directive (LVD) 2014/35/EU Electromagnetic Compatibility EN 61326-1:2013, EMC directive 2014/30/EU Dimensions (W x H x D) 8.85” x 3.93” x 13.97” (225 mm x 100 mm x 355 mm) Weight 5.51 lbs (2.5 kg) Warranty 3 years Standard Accessories Power cord, USB cable, test leads, spare fuses, test report and certificate of calibration Optional Accessories Rack mount kit (RK02), high performance bench DMM accessory kit (TL500B), general purpose DMM kit (TL130B), Maxi-Pro DMM kit (TL50B), replacement probes (TL37) Specifications
About B&K Precision For more than 60 years, B&K Precision has provided reliable and value-priced test and measurement instruments worldwide. Our headquarters in Yorba Linda, California houses our administrative and executive functions as well as sales and marketing, design, service, and repair. Our European customers are most familiar with B&K through our French subsidiary, Sefram. Engineers in Asia know us through our B+K Precision Taiwan operation. Our B&K Brasil office supports our expanding customer base in Brazil and other South American countries. The independent service center in Singapore services customers in Singapore, Malaysia, Vietnam, and Indonesia. B&K Precision group member Independent service center Service center location Video Library View product overviews, demonstrations, and application videos in English, Spanish and Portuguese. http://www.youtube.com/user/BKPrecisionVideos Product Applications Browse all of our supported product and mobile applications. http://bkprecision.com/product-applications B&K Headquarters Yorba Linda, California, USA B&K Brasil Sao Paolo, Brazil Sefram St. Etienne, France B&K Taiwan Taipei, Taiwan Dynamics Circuit Singapore Quality Management System B&K Precision Corporation is an ISO9001 registered company employing traceable quality management practices for all processes including product development, service, and calibration. ISO9001:2015 Certification body NSF-ISR Certificate number 6Z241-IS8