The B &K Precision m odel 549 2B is a versatile 5½ -digit, 120,000-count bench m ultim eter suitable for applications in education, service repair, and m anufacturing. The instrum ent enhances your productivity with built-in m ath functions and U SB connectivity. Rel, M ax/M in, dB m , dB , %, and H old functions provide educators with a convenient tool to teach basic m ath concepts. A dditionally, the 549 2B offers powerful features not com m only found in other 5½ - digit D M M s such as advanced triggering, buffer storage operation, and a G PIB interface option. True RM S Bench M ultim eter 5492B True RM S Bench M ultim eter Increase Productivity w ith PC Connectivity Features & benefits D ata Sheet w w w .bkprecision.com I 5½ -digit, 120,000-count display resolution I 0.01% basic VD C accuracy I A dvanced triggering options such as external, bus and event trigger I Two and four-wire resistance m easurem ent up to 120 M Ω I A C voltage and A C current m easurem ent over wide frequency range (A C V 100 kH z/A C I 10 kH z) I A C (RM S) and D C current m easurem ents up to 12 A I Lim it m ode for Pass/Fail testing I Save/recall up to 10 instrum ent settings I B uilt-in m ath functions: Rel, M ax/M in, dB m , dB , %, H old, Lim it T est I C ATI (1000 V)/C ATII (300 V) protection I U SB (Virtual C om ) and RS232 interface I SC PI com patible Technical data subject to change © B& K Precision Corp. 2017 The 549 2B m easures volts and am ps with great accuracy and stability, with basic VD C accuracy of 0.01%. The m eter is also capable of m easur - ing frequency, period, resistance, continuity, and perform ing diode tests. Readings can be taken at a m axim um rate of 57 readings/sec and stored to an internal 512-byte buffer for post acquisition statistical analysis. The 549 2B was designed for cost-conscious users requiring an accurate m eter with a broad range of features offered at a value price. The 549 2B is program m able via U SB , RS232, and G PIB (549 2B G PIB only) interface using industry standard SC PI com m ands. U sers can rem otely control and configure the instrum ent from a PC and retrieve m easurem ent results for further analysis. The m ultim eter can also be rem otely controlled using application software (via U SB & RS232), which supports front panel em ulation and data logging of m easurem ent results.

2 w w w .bkprecision.com True RM S Bench M ultim eter M odel 5492B Versatile tools L The 549 2B provides an internal buffer capable of storing up to 512 readings. B uffer storage operation can be enabled via front panel or rem ote com m and. The buffer fills up with the requested num ber of readings at a rate of up to 57 readings/sec and then stops. The instrum ent autom atically calculates statistical inform ation based on the stored readings such as m inim um , m axim um , or average reading, and standard deviation, which can then be retrieved along with the readings via the front panel or rem ote com m and. Fast Buffering w ith Built-in Statistics The lim it operation lets you set and control the values that determ ine a H I / IN / LO status of subsequent m easurem ents. The m eter can be configured to em it an audible alarm when readings are outside of the configured lim it. Lim it O peration Rear panel Front panel A variety of advanced trigger options are available: M anual Trigger via a front panel button press, B us Trigger sending a * TRG com m and via PC interface, External Trigger using the EXT TRIG input term inal on the rear panel. A dditionally, a trigger delay can be program m ed after an event detection, and a VM C om p output is available to indicate the instrum ent’s com pletion of a present m easurem ent. A dvanced Triggering Input banana term inals m A Fuse socket Interface keypad Power button B right VFD display G PIB (IEEE-488) interface (m odel 549 2B G PIB ) C hassis ground screw term inal U SB interface RS-232 (Serial) interface External Trigger B NC input term inal Easy operation L Serial num ber label Power line fuse holder VM C om p (Voltm eter com plete) B NC output term inal

3 w w w .bkprecision.com True RM S Bench M ultim eter M odel 5492B Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading A ccuracy (1 year) Typical Input Im pedance 120.000 m V 1 µV 119 .9 9 9 0.02+ 0.008 (1) >10 G Ω 1.20000 V 10 µV 1.19 9 9 9 0.01+ 0.004 (1) >10 G Ω 12.0000 V 100 µV 11.9 9 9 9 0.01+ 0.004 >10 G Ω 120.000 V 1 m V 119 .9 9 9 0.01+ 0.004 10 M Ω ± 1% 1000.00 V 10 m V 1010.00 (2) 0.01+ 0.004 10 M Ω ± 1% (1) under REL status (2) 1% overrange (1010 V) is readable at 1000 V range D C Voltage A C Voltage (True RM S, A C coupled) Specifications M easurem ent m ethod: A C coupled true RM S, m easuring the A C com ponent only M axim um C rest factor: 3.0 at full scale Input im pedance: 1 M Ω ± 2% in parallel with capacitance < 100 pF Input protection: 7 50 Vrm s, 500 Vdc Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading A ccuracy (1 year)(1) 10- 2 0 H z 2 0- 50 H z 50- 2 0 kH z 2 0- 50 kH z 50- 100 kH z (1) Specifications are for sine wave inputs >5% of range (2) ≤3× 10 7 Volt-H z for 7 50 V range (3) 1% overrange (7 57 .5V) is readable at 7 50 V range Specifications are based on the follow ing conditions: I O ne year calibration cycle I O perating tem perature between 18 °C to 28 °C I A ccuracy expressed as: ± (% of reading + % of range) after 30 m inutes warm -up and valid for 10 PLC (Slow) I T em perature coefficient: add ± [0.1% × (applicable accuracy)/°C ] for 0 °C to 18 °C and 28 °C to 40 °C I Relative hum idity: U p to 80% RH for 0 °C to 28 °C (7 5% RH for 10 M Ω and above ranges for resistance m easurem ent), up to 7 0% RH for 28 °C to 40 °C Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading A ccuracy (1 year) B urden Voltage(1) & Shunt Resistor (1) Typical voltage across the input term inals at full scale reading (2) U se REL function (3) In 12 A range, >10~ 12 A D C is readable for 20 seconds m axim um D C Current Input protection: 1000 V Input protection: Externally accessible 2A / 250V fuse protecting the low input current term inal (LO ). Internally accessible 20A / 250V fuse protecting the high current input term inal (10A )

4 w w w .bkprecision.com True RM S Bench M ultim eter M odel 5492B Resistance (2-W ire and 4-W ire) Continuity Specifications (cont.) Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading B urden Voltage(1) & Shunt Resistor A ccuracy (1 year)(3) 10- 2 0 H z 2 0- 50 H z 50- 2 kH z 2 - 2 0 kH z (1) Typical voltage across the input term inals at full scale reading (2) In 12 A range, >10-12 A A C is readable for 20 seconds m axim um (3) Specifications are for sine wave inputs >5% of range A C Current (True RM S, A C Coupled) Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range(1) Resolution Full Scale Reading Test C urrent A ccuracy (1 year) 120.000 Ω 1 m Ω 119 .9 9 9 1 m A 0.05 + 0.008 (2) 1.20000 kΩ 10 m Ω 1.19 9 9 9 1 m A 0.03 + 0.004 (2) 12.0000 kΩ 100 m Ω 11.9 9 9 9 100 µ A 0.03 + 0.004 (2) 120.000 kΩ 1 Ω 119 .9 9 9 10 µ A 0.03 + 0.004 1.20000 M Ω 10 Ω 1.19 9 9 9 10 µ A 0.03 + 0.004 (1) In order to elim inate the noise interference, which m ight be induced to the test leads, it is recom m ended to use a shielded test cable for m easuring resistance above 120 k Ω (2) U sing REL function Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading Test C urrent A ccuracy (1 year) 1 k Ω 100 m Ω 9 9 9 .9 1 m A 0.1%+ 0.02% D iode Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C Range Resolution Full Scale Reading Test C urrent A ccuracy (1 year) 3.0000 V 100 µV 2.9 9 9 9 1 m A 0.030+ 0.020 10.0000 V 100 µV 10.0000 100 µA 0.030+ 0.020 10.0000 V 100 µV 10.0000 10 µA 0.030+ 0.020 M easurem ent m ethod: A C coupled true RM S, m easuring the A C com ponent only Input protection: Externally accessible 2 A / 250 V fuse protecting the low input current term inal (LO ). Internally accessible 20 A / 250 V fuse protecting the high current input term inal (10A ) M ax. crest factor: 3.0 at full scale Input protection: 1000 Vdc or 7 50 Vac for all ranges Note: Rx is the m easured resistance value For 0.1 PLC (Fast) Input protection: 1000 Vdc or 7 50 Vac For 1 PLC (M edium ) Input protection: 1000 Vdc or 7 50 Vac for all ranges

Specifications (cont.) 5 w w w .bkprecision.com True RM S Bench M ultim eter M odel 5492B v052517 Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C A C V Range P eriod Range Resolution Full Scale Reading A ccuracy(2) Input Sensitivity (Sine W ave) 100 m V to 7 50 V 1 ~ 10 µs (1) 0.01 ns 9 .9 9 9 9 9 0.005 100 m Vrm s 10 µs ~ 10 m s 0.1 ns 9 .9 9 9 9 9 0.005 40 m Vrm s 10 m s ~ 100 m s 0.1 µs 9 9 .9 9 9 9 0.01 40 m Vrm s 100 m s ~ 200 m s 1 µs 19 9 .9 9 9 0.05 200 m Vrm s (1) If testing frequency is greater than 1M H z, it will be displayed but no specified accuracy is guaranteed. (2) Specified accuracy at input >5 % of range. Supplem ental Environm ental O perating Environm ent 0 °C to 40 °C , 32 ºF to 104 ºF Storage Environm ent -40 °C to 7 0 °C -40 ºF to 158 ºF H um idity ≤ 9 0 %RH G eneral Rem ote Interfaces RS232, U SB (virtual C O M ) G PIB (m odel 549 2B G PIB only) M easurem ent C ategory C AT II 300V , C AT I 1000V , pollution degree 2 M ath Functions Rel, M ax/M in/A verage/StdD ev (for stored readings), dB , dB m , Lim it T est, % and m X+ b A C Input 110/220 V ± 10%, 50/60 H z ± 5% P ow er C onsum ption ≤ 20 VA Safety & EM C EN 61010-1:2001, EN61326-1:2006 and EN61326-2-1:2006 D im ensions (W × H × D ) 8.85” x 3.9 3 “ x 13.9 7 ” (225 m m × 100 m m × 355 m m ) N et W eight 5.51 lbs (2.5 kg) Three-Year W arranty Included A ccessories T est leads, A C power cord, spare fuse, user m anual, U SB cable, calibration certificate and test report Frequency Resolution, Full Scale Reading and A ccuracy ± (% of reading + % of range), 23 °C ± 5 °C A C V Range Frequency Range Resolution Full Scale Reading A ccuracy(2 ) Input Sensitivity (Sine W ave) 100 m V to 7 50 V 5 ~ 10 H z 10 µH z 9 .9 9 9 9 9 0.05 200 m Vrm s 10 ~ 100H z 100 µH z 9 9 .9 9 9 9 0.01 40 m Vrm s 100 ~ 100 kH z 1 m H z 9 9 9 .9 9 9 0.005 40 m Vrm s 100 k ~ 1 M H z (1) 1 H z 9 9 9 .9 9 9 0.005 100 m Vrm s (1) If testing frequency is greater than 1M H z, it will be displayed but no specified accuracy is guaranteed. (2) Specified accuracy at input >5 % of range. G ate Tim e at 1 Sec. Input protection: 7 50 Vrm s or 500 Vdc G ate Tim e at 1 Sec. Input protection: 7 50 Vrm s or 500 Vdc