54831 HP | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 30
Technical content
Infiniium 54830 Series Oscilloscopes
Contents
Options and Accessories 12 Performance Characteristics 18 Purchasing Alternatives 25 Ordering Information 26
Combining the benefits of industry-leading MegaZoom deep memory and mixed-signal oscilloscope models, Infiniium makes it faster and easier than ever to see what's happening in your high-speed digital or communications design. View and Trigger on up to 4 Analog and 16 Digital Channels With the Agilent 54830D Series of Mixed-Signal Oscilloscopes (MSOs), you can easily view the complex relationships of your analog and digital signals, as well as the analog characteristics of digital signals. If your embedded designs include complex digital buses such as PCI or SDRAM, the 54830D Series of MSOs allow you to easily trigger on and view up to 20 time-aligned analog and digital signals to isolate problems and cycles of interest. Industry-Leading Deep Memory with Instant Response With up to 128 Mpts of acquisi- tion memory, the Agilent 54830 Series of MSOs and DSOs offers superior resolution when captur- ing long, complex waveforms. But a deep-memory scope doesn’t have to be difficult to use. Infiniium scopes from Agilent utilize MegaZoom technology through the full 128 Mpts for fast waveform updates and respon- sive user input controls. The Performance You Need
- 600 MHz to 1 GHz bandwidth
- 2+16-, 4+16-, 2- and 4-channel models
- Up to 4 GSa/s
- Up to 4 Mpts memory standard; up to 128 Mpts optional
- Advanced probing solutions Award-Winning Scopes Infiniium has received eight industry awards to date, including EDN’s“Innovation of the Year” award (twice) and T&M World’s “Best in Test.” Agilent is commit- ted to breaking new ground and providing tools that bring unique value to our customers.
“Everything is where you want it to be. Readouts, knobs — they are easy to see, easy to use.” Matt Berger Senior Engineering T echnician National Semiconductor “Other scopes are hard to use, hard to maneuver. With Infiniium, it’s easy to find your way around when you’re looking for advanced features.” Norm Reed Radar Systems T echnologist Canadian Department of National Defense “We use Infiniium to save large quan- tities of screen shots on our LAN — then we pull them up immediately over the network. It saves a lot of time and a lot of hassle.” Stu Nuffer Senior Systems Engineer LSI Logic ”Complex triggering has its place, but sometimes I just want to capture everything and look at it.” Chuck Hill Consultant Alta Engineering Here’s what engineers are saying about their Infiniium scopes. Simple things are simple Analog-like front panel provides simple controls for basic func- tions — easy to find and easy to use. Easy access to advanced features Familiar Windows®-based graph- ical user interface makes it easy to navigate and access advanced features. Convenient communication and data sharing PC architecture with a standard LAN interface makes it easy to share your work and communi- cate your results. Automatic deep memory with instant response With Infiniium’s MegaZoom deep memory, you can easily make long single-shot acquisitions and search through your data with instant response.
Powerful Mixed-Signal Triggering No matter how complicated the signals you’re dealing with, the Infiniium MSO has a triggering feature that can help you easily untangle it. The Infiniium MSOs provide you with the most com- plete triggering functionality ever offered in an oscilloscope. The 54830D Series Infiniium MSOs come with powerful trig- gering capabilities across all 16 digital channels and all available analog channels so you can easily isolate and analyze complex signals and interactions in your mixed analog and digital designs. X-Ray Vision for Your FPGAs The new N5397A FPGA Dynamic Probe for the Infiniium MSO enables its 16 digital channels to capture and trigger on signals inside of your Xilinx FPGA that can then be correlated to exter- nal analog activity. Seamless Integration of Analog and Digital Channels The Agilent 54830D Series Mixed-Signal Oscilloscopes unique- ly combine the detailed signal analysis of a high-performance scope with the 16-channel timing measurements of a logic analyzer, plus the benefits of fast, usable, and affordable MegaZoom deep memory. On one display you can have both the analog circuit charac- teristics displayed on the 2 or 4 scope channels and the digital signals displayed on the 16 logic timing channels. Digital and analog events are aligned in time so you can easily relate cause and effect in difficult mixed-signal troubleshooting situations. The analog and digital channels are seamlessly integrated giving you familiar scope-like controls of both the analog and digital tim- ing channels. And there is no compromise on the scope side — you just can treat all 18 or 20 channels the same. Verifying and analyzing your mixed-signal design Here we see a data line and the clock of a standard SDRAM isolated in a write cycle. This was accomplished by triggering with 4 digital channels and 1 analog channel of the 54833D MSO when the SDRAM’s CS, CAS, and WE lines are low, while RAS is high on the rising edge of the clock. The second analog channel is used for looking at the analog characteristics of a data line. The increased channels, deep memory, and advanced triggering of an MSO can help you debug today's complex designs more efficiently than you could with a DSO. Trying to do this with a traditional 2- or 4-channel DSO would be difficult or impossible. The traditional option for measuring a multi-channel system would be to connect and configure a logic analyzer with a DSO which can be costly and time-consuming. Fortunately, Agilent’s MSO fills this need without the cost or frustration.
The 54830 Series Infiniium scopes use advanced MegaZoom technology so you get all the ben- efits of fast, automatic, affordable deep memory. Due to its unique ASIC architecture, this powerful memory management system called MegaZoom can quickly display up to 128 million points of continuous signal history without the usual bottlenecks and frustrating delays. Industry-leading deep memory up to 128 Mpts, without annoying delays Instant Response While first-generation deep- memory scopes update the display slowly, Infiniium’s MegaZoom memory management system instantaneously updates the display even with the deepest memory. And deep memory is on all the time — so you always have the maximum available sample rate and don’t undersample or miss fast events. Discover prob- lems you never found with your first-generation deep-memory scope. Optimum Resolution Get the insight you need to solve your debugging challenges in a fraction of the time it used to take. Just press the Autoscale key to automatically adjust the sample rate to achieve the best waveform resolution. Then, as you change the horizontal scale to display more time and view your entire signal, MegaZoom adds more memory to give you the fastest sample rate and best resolution possible. Now you can automatically see events as narrow as 250 ps without using a special mode such as peak detect. Unprecedented Deep Memory Every Infiniium 54830 Series with MegaZoom is a deep-memory oscilloscope with up to a standard
2 Mpts of memory on each chan-
nel. Now memory options are available to configure your scope with up to 128 Mpts to capture the longest waveforms without reducing sample rate. By combining powerful features, ease of use, and industry-leading specifications, Infiniium scopes help you find answers faster. A simple, analog-like front panel, Windows-based interface to easily access advanced features, and powerful connec- tivity make high-performance capabilities of Infiniium usable.
See fast events — as fast as 250 ps — without using special modes like peak detect. Peak points are displayed in a darker color than the waveform indi- cating more data points are available. Just zoom in to see the event in detail. Drag and drop markers with your mouse or use the arrow keys. Bus mode display allows quick readout of digital channel value in hexa-decimal representation at every transition. See your signal more clearly with a large (8.4-inch) high-resolution color display. Infiniium's bright TFT display with anti-glare coating lets you see the details of your signal from all angles. Store all your setups and results on the ≥20 GB hard drive for future recall or sharing via the LAN interface. Order option 017 to make it removeable for operation in secure environments. Remote access with web-enabled connectivity, e-mail on trigger, and GPIB over LAN. Windows ® XP Pro based open platform makes it easier than ever to run Windows applications inside f Infiniium. Save all waveforms, including digital and analog channels, that allows you to store multiple waveforms in ASCII file formats to a single file with a single mouse click. Infiniium: “It’s like someone who sits down and actually uses a scope designed this one.” Steve Montgomery Director of Engineering, Linx T echnologies Get fast answers to your questions with the built-in information system. Infiniium's task-oriented Setup Guide provides step-by-step instructions for several advanced measurements and procedures. Maximum sample rate and resolution on every measurement. The scope automatically adjusts memory depth up to 128 Mpts as you use it, so you get maximum sample rate and resolu- tion on every measurement. You don't even have to think about it. Pick out anomalies easily with intensity-graded persistence mode, color-graded persistence, a colorful visual representation of waveform distribution. QuickMeas+ gives you any four auto- mated measurements with the push of a button. You can also configure this key to print/save screen shots, save waveforms, or load a favorite setup. With the E2699A My Infiniium Software option, configure the QuickMeas+ key to execute a custom analysis executable program.
Autoscale automatically sets deep memory to the amount required up to 128 Mpts for the maximum sample rate and resolution. You never have to set deep memory manually. Segmented memory acquisition mode captures bursting signals at maximum sample rate without con- suming memory during periods of inactivity for very long periods of time. A familiar interface makes simple tasks simple. Infiniium's analog-like front panel has a full set of controls color coded to the LEDs, waveforms, and measurements. Easy access to advanced features like math and FFTs is provided by the Windows-based graphical user inter- face. This GUI also gives you unique capabilities like drag-and-drop measure- ments and zooming, and offers a graphi- cal equivalent to all front panel controls. AutoProbe interface completely configures your scope for use with a wide range of passive, active and differential probes. 10/100 Mbps LAN interface lets you easily print waveforms on networked printers, save your results on your office PC, and share information with others. Roll mode display allows for continuous scrolling capture of slow analog signals Hands-free operation with the Infiniium VoiceControl option. Just speak into the collar-mounted micro- phone to operate front-panel controls. Label waveforms and add notes to your screen captures — Infiniium's keyboard makes it easy. Built-in CD-ROM drive on the rear panel allows you to update the system software conveniently. Zoom and search with instant response. Zoom into your signal using the horizontal scale knob and search through your waveform with the posi- tion knob. Find your area of interest quickly and easily. 4 analog and 16 digital channel MSOs allow you to see up to 20 time- aligned signals on your scope screen. Also available in 2+16- , 2- and 4- channel models.
Infiniium: Helping you get the job done faster Drag-and-Drop Measurements It’s simple: drag an icon from the measurement bar and drop it on the cycle you want to measure. You can make up to four meas- urements on your waveforms, on up to four different cycles. All the measurements appear at the bottom of the display with statistics and are color coded to the channel you are measuring. Scope measurements have never been this powerful or this easy. Dialog Boxes for Easy Setup With Infiniium, you don’t need to navigate through annoying softkey menus. Dialog boxes display all the choices you need for measurement setups, all in one place. Help is available for each field, guiding you through each step. Bus Mode Display Bus mode display on MSOs allows quick and easy read-out of hexa-decimal representation of logic signals. Bus state mode display allows the bus readout to be updated only upon the edge of the clock source you select. Available only with 54830D Series MSOs. Simple Zooming Zooming with Infiniium’s graphi- cal user interface is simple and convenient. Just use the mouse to draw a box around the area of interest and click inside. Zoom uses the full display so you get meaningful vertical as well as horizontal resolution gains. Use multiple zoom boxes to see deep inside your signal. Zooming couldn’t be simpler or faster. Segmented Memory Acquisition Mode* Are you trying to capture com- munications or radar signals that are bursting in nature? The new Segment Memory acquisition mode allows you to capture the short bursts at maximum sample rate while not consuming memory during the periods of inactivity. * Standard feature with version A.03.70 system software or higher, but only available on 54830B/31B/32B models with serial number MY41003401 or greater, 54830D/31D/32D models with MY42001701 or greater, or 54833A/33D models with MY43000601 or greater.
Mask testing is simplified with AutoMask. Acquire a waveform, define tolerance limits, and create a test envelope. Mask testing pro- vides a pass/fail comparison of an incoming signal to the test enve- lope. Easily test your design’s con- formance to industry standards with the Communication Mask Test Kit option. Advanced Triggering Advanced triggers are essential when investigating known prob- lems. Infiniium offers a full range of advanced triggers to help you isolate and capture the con- dition you need to characterize. Advanced trigger setups are sim- plified by using intuitive dialog boxes with descriptive graphics. Color-Graded Persistence with Histograms By providing seven levels of color grades for a visual representation of waveform distribution, color-graded persistence makes it easy to pick out signal anomalies and see how often they occur. Histograms quantify both noise and jitter in your target system. Infiniium: Simplifying tasks with easy access to advanced features Intensity-Graded Persistence The intensity-graded persistence mode displays waveforms in the seven levels of intensity grades, enabling you to capture elusive signal anomalies in complex waveforms using user defined decay time. High/Low Pass Filter Applies a real-time digital filter to the source waveform that you choose. This filtering feature enhances your ability to examine important signal components by filtering out unwanted frequency components. QuickMeasure and Statistics Instantly make four common measurements on your signal, with easy-to-read statistics, by pressing the QuickMeas+ button on the front of your Infiniium. The measurements displayed can be easily customized.
Infiniium: Simplifying tasks with easy access to advanced features E-Mail on Trigger Infiniium can automatically send an e-mail with a bit map of the display when the scope triggers. You can have your Infiniium send an e-mail to you or a message to your cell phone then control your scope from any Java-enabled web browser. Web-Enabled Control For distributed teams, simply set up Infiniium on your LAN, and up to three users can access it from any Java™-enabled Web browser. No special software is required. You can easily grab screen shots for a report, or troubleshoot designs at a remote location. Dual Monitor Support Dual Monitor mode allows you to run third-party applications on a large, external monitor with up to SXGA resolution (1280 x 1024 pixels) while using the scope’s built-in monitor for waveform display. Infiniium IVI-COM Driver For higher-level of instrument control, utilize the Infiniium IVI-COM instrument driver in your application. This IVI-COM driver takes full advantage of industry accepted standards and is compatible in application development environments such as Visual Studio® as well as in test and measurement development environments such as Agilent VEE Pro and National Instruments® LabView®. The Infiniium IVI-COM Instrument driver allows for easier use, higher performance, and instrument interchangeability in your oscillscope control program. Download the Infiniium IVI-COM driver for free from Agilent Developer’s Network at www.agilent.com/find/adn. Windows XP Pro Open System Want to run Windows applica- tions inside your Infiniium scope? Yes you can. All Infiniium
54830 Series scopes are based on
Windows XP Pro open platform that allows you to run Windows applications inside the Infiniium to add advanced analysis and functionaliy to the scope.
- Standard feature with version A.03.70 system software or higher, but only available on 54830B/31B/32B models with serial numbe r MY41003401 or greater, 54830D/31D/32D models with MY42001701 or greater, or 54833A/33D models with MY43000601 or greater. Infiniium: High-performance scopes at competitive prices
54800 Series Infiniium Oscilloscopes
Maximum Standard Optional Maximum Mode Bandwidth Channels Sample Rate Acquisition Memory Acquisition Memory 54830D 600 MHz 2+16 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54831D 600 MHz 4+16 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54832D 1 GHz 4+16 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54833D 1 GHz 2+16 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54830B 600 MHz 2 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54831B 600 MHz 4 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54832B 1 GHz 4 4 GSa/s 2 Mpts/ch (4 Mpts max.) 64 Mpts/ch (128 Mpts max.) 54833A 1 GHz 2 4 GSa/s 500 kpts/ch (1 Mpts max.) 64 Mpts/ch (128 Mpts max.) Common to All Infiniium 54830 Series Oscilloscopes
- 600 MHz and 1 GHz bandwidths
- Maximum 4 GSa/s sample rate
- 2 Mpts/ch MegaZoom memory standard (4 Mpts max) (except for 54833A)
- Optional up to 64 Mpts memory per chan- nel (up to 128 Mpts max)
- Segmented Memory acquisition mode*
- Windows XP Pro based open system
- Simple analog-like front panel
- Advanced features are accessible with Windows GUI
- File and printer sharing with LAN
- Web-enabled, remote control from any web browser
- E-mail on trigger
- Intensity-graded persistence
- High/low pass filter functions
- Dual monitor support
- Advanced triggering
- Color-graded persistence and histograms
- Drag-and-drop measurements and zoom boxes
- USB (2), PS/2 (2), GPIB, VGA, LAN, Centronics ports
- QuickMeasure+
- Statistics
- Built-in information system
- ≥20 GB HDD, 1.44 MB floppy
- Waveform labels
- Math functions including FFTs
- Advanced, quiet multi-fan cooling system
- CD-ROM drive
- Optical USB mouse, condensed PS/2 keyboard
- ATX PC motherboard
- Pentium ® III 1 GHz processor
- 512 MB CPU memory
- Eye diagram measurements
- AutoMask
- FPGA dynamic probe (for MSO models only)
- Low-speed serial data analysis option
- High-speed serial data analysis with clock recovery option
- My Infiniium integration package option
- EZJIT jitter analysis software option
- Time interval and jitter analysis option
- Ethernet compliance test option
- Communications mask testing option
- USB 2.0 test option (for 4-ch or 4+16-ch models only)
- VoiceControl option for hands-free control
- Support for Infiniium AutoProbes
- Standard 1-year warranty
open operating system with expanded 512MB CPU memory. The new system software offers users reliable system perform- ance and the ability to run Windows applications inside the scope, making it a one-box acquisition/analysis solution. Infiniium Performance Upgrade Kit (N5383A) The N5383A Infiniium Performance Upgrade Kit upgrades your existing Infiniium
54830 Series oscilloscopes to
the A.03.10 or higher version of the system software based on application directly from the oscilloscope’s front panel or graphical user interface. Any program that can be run under Windows XP can be launched from Infiniium scope, including applications such as Agilent VEE, Microsoft Excel, or MATLAB®. My Infiniium Integration Package* (Option 006 or E2699A) The E2699A My Infiniium Integration Package option allows you to extend the power of your Infiniium oscilloscope by letting you launch your hold time, measurement his- tograms, measurement trending and jitter spectrum. Our jitter option provides a setup wizard to guide you through the setup of the jitter measurement, how each jitter measurement works, and tells you when to use it. EZJIT Jitter Analysis Software* (Option 015 or E2681A) The E2681A Jitter Analysis option provides the most commonly needed jitter meas- urements, including cycle-cycle jitter, N-cycle jitter, period jitter, time interval error, setup and signals. The option provides four mask templates for 10BaseT testing, two mask templates for 100BaseT testing, and six mask templates for 1000BaseT testing as defined by IEEE 802.3 specification. Ethernet Masks* (E2698A) The E2698A Ethernet Masks option provides mask templates for 1000BaseTX, 100BaseT and 10BaseT. These masks provide pass/fail testing for Ethernet with the Infiniium 54830 Series oscilloscopes provides the most repeatable and fully-featured jit- ter measurements for serial data streams, PLLs and high-speed clock designs. Time Interval and Jitter Analysis* (E269xA and N538xA) The E269xA and N538xA Time Interval and Jitter Analysis soft- ware licensed from Amherst System Associates combined * This option works with all 54830 Series Infiniium oscilloscopes and requires Infiniium system software version A.03.10 or highe r. Existing 54830 Series users can order the N5383A Infiniium
Options and Accessories continued USB 2.0 Test Option (E2683A or N2855A) The E2683A or N2855A USB 2.0 test option makes USB signal- integrity compliance testing as simple as capturing the signals with your Infiniium 4-ch or 4+16-ch oscilloscope. The Infiniium USB 2.0 test option features run-time MATLAB® embedded in the scope for use with the USB signal integrity scripts, providing a one-box solution. The USB-IF compliance program recognizes Infiniium as a recommended scope for use in compliance testing. In addition, all MATLAB scripts used with the USB test option come from the USB-IF organization. The E2683A or N2855A includes both the USB test option software and Signal Quality Inrush Droop/Drop (SQiDD) test fixture. Additional SQiDD test fixtures can be purchased sepa- rately by ordering the E2646A. High-Speed Serial Data Analysis Software † (Option 003 or N5384A) The N5384A High-Speed Serial Data Analysis (SDA) software provides an effective way to validate signal integrity for designs employing high-speed serial interfaces with embedded clocks. The High-Speed SDA software, when used with the Agilent 54830 Series Infiniium oscilloscopes, allows you to:
- recover embedded clocks with first-order PLL, second-order PLL, or constant frequency algorithms
- choose an external reference clock input
- display the recovered clock synchronized with the analog waveform view of the serial data stream
- build real-time eye diagrams
- unfold real-time eye diagrams to easily locate failures versus time
- perform custom mask testing
- make TIE jitter measurements relative to the recovered clock or external reference clock Low-Speed Serial Data Analysis Software † (Option 021 or N5391A) The N5391A Low-Speed Serial Data Analysis (SDA) software provides a fast and easy way to debug Inter-Integrated Circuit 2C) and 2-wire or 3-wire Serial Peripheral Interface (SPI) serial communication busses. The Low-Speed SDA software, when used with the Agilent 54830 Series or 54850 Series Infiniium oscilloscopes, provides the ability to capture and automatically display decoded serial data in numerical format synchronized with the analog or digital wave- form view of I 2C or SPI serial data streams. † This option works with all 54830 Series Infiniium oscilloscopes and requires version A.03.50 (Windows XP Pro) system software or higher. Existing 54830 Series users can
Ethernet Performance Validation and Compliance Software† (N5392A) The N5392A Ethernet electrical performance validation and compliance option provides you with a fast and easy way to verify and debug your 1000Base-T, 100Base-TX and 10Base-T Ethernet designs. The Ethernet electrical test software, allows you to automatically execute Ethernet physical-layer (PHY) electrical tests, and it displays FPGA Dynamic Probe for Infiniium MSO* (N5397A) The new N5397A FPGA Dynamic Probe for the Infiniium MSO pro- vides the most effective solution for validating and debugging embedded designs incorporating Xilinx FPGAs. This innovative solution enables you to:
- View internal FPGA activity correlated to external analog events — With the FPGA dynamic probe, the Infiniium MSO’s 16 digital channels can be used to access hundreds of internal signals, unlocking visibility into your design that you never had before. With the power of the MSO, these inter- nal FPGA signals can be corre- lated to external analog con- tent for determining cause and effect relationships. Options and Accessories continued * This option works with all 54830 Series Infiniium mixed-signal oscilloscopes and requires version A.03.90 system software or h ighter. Existing 54830 Series users can order † This option works with all 54830 Series Infiniium oscilloscopes and requires version A.03.50 (Windows XP Pro) system software or higher. Existing 54830 Series users can
- Make multiple measurements in seconds — Moving probe points internal to an FPGA used to require time consuming design recompiles. Now, in less than a second you can easily measure a different set of internal sig- nals without design changes. By not changing the design, FPGA timing stays constant when you select new sets of internal signals for probing.
- Leverage the work you did in your design environment — The FPGA dynamic probe automatically maps internal signal names from your FPGA design tool to the MSO’s digital channel labels. This provides easy sig- nal identification and elimi- nates unintentional mistakes while saving hours of time. the results in a flexible report format. In addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test. The Agilent N5395A Ethernet electri- cal compliance test fixture and N5396A Gigabit Ethernet jitter test cable are available for making the physical connection between the Infiniium oscillo- scope and the device under test.
Options and Accessories continued Communication Mask Test Kit (E2625A) Take the frustration out of com- munications testing and prove your designs conform to indus- try standards with the Communication Mask Test Kit option. Infiniium’s familiar Windows interface makes it easy for you to access the masks you need and configure your tests. In addition, the Communication Mask Test Kit comes with a set of electrical communication adapters to ensure convenient, reliable, and accurate connections to your device under test. Includes more than 20 industry-standard ANSI T1.102, ITU-T G.703, and IEEE 802.3 communication sig- nal mask templates. This option works with all Infiniium 54800 Series oscilloscopes. Logic Analyzer/Oscilloscope Time-Correlation Fixture (E5850A) Now you can more effectively verify and track down problems between the analog and digital portions of a design. Easily make time-correlated measurements between an Agilent 16700 Series logic analysis system or Agilent 1680/90 Series benchtop logic analyzer and an Infiniium 54800 Series oscilloscope. With the Vector Signal Analysis software for Infiniium (89601A) The 89601A Vector Signal Analyzer (VSA) software, used with the Infiniium oscilloscope, enables flexible signal analysis and demodulation up to 13 GHz bandwidth for troubleshooting wideband modulated signals in E5850A Time-Correlation Fixture, you can trigger the Infiniium from the logic analyzer (or vice versa), automatically deskew the waveforms, and simultaneously view the Infiniium analog wave- forms and the logic analyzer’s timing waveforms on your Agilent logic analyzer. This option works with all Infiniium 54800 Series oscilloscopes. radar and communications appli- cations. The solution provides:
- Flexible demodulation for meas- uring constellation diagrams, carrier offset, and frequency error for QPSK signals, 256 QAM signals and much more
- display formats including spectrogram, phase vs. time, and frequency vs. time for rapid insight into complex signal behavior
- Error vector magnitude measurements (with 89601A option AYA)
- Markers to facilitate frequency, amplitude, offset, power, phase, other measurements
- Time gating that allows you to select specific portion of signals for signal analysis
- Variable frequency resolution
Options and Accessories continued Instrument Viewer® The MicroOptical® SV-3 Instrument Viewer projects an image of your Infiniium VGA display in front of you, like having a monitor anywhere you want it. For additional informa- tion and ordering instructions, contact the MicroOptical Corp or see http://www.microoptical.net. VoiceControl Option (E2682A or N2850A) If you’re making measurements on target systems with densely packed ICs, your hands are tied up holding probes, making it difficult to turn knobs and press buttons on the front panel of your scope. Infiniium’s award- winning VoiceControl option solves this problem. Just speak into the collar-mounted microphone to operate your Infiniium’s front-panel controls without using your hands. Simply tell the scope what you want it to do, using natural English-language commands, Testmobile (1184A) Agilent’s 1184A testmobile pro- vides a convenient solution for your portability and storage needs. The 1184A includes a drawer for accessories and a keyboard tray with a mouse extension for either right- or left-hand operation. such as “set channel one to 1.25 volts per division.” The VoiceControl system does not require the scope to be trained to understand a particular user. This option works with all Infiniium 54800 Series oscilloscopes. Order N2850A for an existing Infiniium 54830 Series (version A.02.xx) purchase. Order E2682A for a new Infiniium 54830 Series (version A.03.10 or later) purchase.
Options and Accessories continued Active Probes (Options 011, 012, 019) Probing high-frequency signals becomes more challenging as the variety of test points and the fre- quencies of the signals continue to grow. Probes need to be light- weight, small, affordable, and offer the accessories and probe tips you require to get your job done easily. For high-speed differential signal measurements, the 1130A InfiniiMax differential probe is a perfect compliment to the Infiniium 54830 Series oscillo- scopes. Its 1.5 GHz probe band- width, extremely low input capacitance, high common mode rejection and the patented resis- tor probe tip technology provide ultra-low loading of the DUT and superior signal fidelity. The 1156A active probe is a small, low-mass, active probe with bandwidth up to 1.5 GHz. The probe offers a flat frequency response across the entire probe bandwidth, giving you accurate insight into your high-speed measurement. Agilent offers a variety of probe tips to help you probe any test point, and the revolutionary EZ-Probe Positioner® option provides sta- ble, accurate X, Y, Z positioning of your probe. The 1155A probe is a low-mass, versatile, and affordable 2-chan- nel, 750-MHz active probe. Used with an optional Wedge Probe Adapter, this combination is an excellent solution for probing TQFP and PQFP packages. When used with the standard grabber tips, the 1155A can be used to probe any test point. When used with the 600 MHz Infiniium oscilloscopes, this pairing deliv- ers 2 channels with a system bandwidth of 500 MHz. For more information on probing solutions, accessories, and options, please visit our web site at www.agilent.com/find/infiniium; and see the Infiniium 54800 Series Oscilloscope Probes, Accessories, and Options Selection Guide, (Agilent litera- ture No. 5968-7141 EN/EUS) and many other useful documents and webpages. Single-Ended/ Model Probe Bandwidth System Bandwidth Channels Differential Option No. 1155A 750 MHz 500 MHz with 54830B/D or 31B/D 2 single 011 1156A 1.5 GHz 1 GHz with 54832B/D or 33A/D 1 single 012 1130A 1.5 GHz 1 GHz with 54832B/D or 33A/D 1 differential* 019 * InfiniiMax 1130A probe amplifier supports both differential and single-ended measurements, depending on the choice of probe he ad and accessories.
Vertical : Analog Channels 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Input Channels 54830B/54833A: 2 analog 54830D/54833D: 2 analog + 16 digital 54831B/54832B: 4 analog 54831D/54832D: 4 analog + 16 digital Analog Bandwidth @50 Ω (-3 dB)*1 54830B/D, 54831B/D: 600 MHz 54832B/D, 54833A/D: 1 GHz Calculated Rise Time2 @50 Ω 54830D/B, 54831B/D: 583 ps 54832B/D, 54833A/D: 350 ps Input Impedance* 1 MΩ ± 1% (13 pF typical), 50 Ω ± 1.5% Sensitivity3 1 mV/div to 5 V/div (1 M Ω) 1 mV/div to 1 V/div (50 Ω) Input Coupling 1 MΩ: AC, DC; 50 Ω:DC Hardware Bandwidth Limit 20 MHz Vertical Resolution4 8 bits, ≥12 bits with averaging Channel-to-Channel Isolation DC to 50 MHz: 50 dB (any two channels with equal V/div settings) >50 MHz to 500 MHz: 40 dB >500 MHz to 1 GHz: 30 dB DC Gain Accuracy*3, 5 ± 1.25% of full scale at full resolution channel scale Maximum Input Voltage*
1 MΩ 150 V RMS or DC, CAT I
± 250 V (DC + AC) in AC coupling 50 Ω 5 Vrms, CAT I Offset Range Vertical Sensitivity Available Offset
1 MΩ 1 mV to <10 mV/div ± 2 V
10 mV to <20 mV/div ± 5 V 20 mV to <100 mV/div ± 10 V 100 mV to <1 V/div ± 20 V
1 V to 5 V/div ± 100 V
50 Ω 1 mV to <5 mV/div ± 2 V 5 mV to <200 mV/div ± 5 V 200 mV to 1 V/div ± 20 V Offset Accuracy*3 ± (1.25% of channel offset+2% of full scale+1 mV) Dynamic Range ± 8 div from center screen (1 M Ω) ± 12 div from center screen (50 Ω) DC Voltage Measurement Accuracy*3, 5 Dual Cursor ± [(DC gain accuracy)+(resolution)] Single Cursor ± [(DC gain accuracy)+(offset accuracy)+(resolution/2)] Example for single cursor accuracy for 70 mV signal, 10 mV/div, 0 offset: Accuracy = Performance Characteristics
Vertical: Digital Channels (54830D/31D/32D/33D only) Number of Channels 16 Digital – labeled D15 – D0 Threshold Groupings Pod 1: D7 – D0 Pod 2: D15 – D8 Threshold Selections TTL, 5.0V CMOS, 3.3V CMOS, 2.5V CMOS, ECL, PECL, User Define d User-Defined Threshold Range ±8.00 V in 10 mV increments Maximum Input Voltage ±40 V peak CAT I Threshold Accuracy* ±(100 mV + 3% of threshold setting) Input Dynamic Range ±10 V about threshold Minimum Input Voltage Swing 500 mV peak-to-peak Input Impedance 100 kΩ ± 2% (~ 8 pF) at probe tip Channel-to-Channel Skew 2 ns typical, 3 ns maximum Glitch Detect ≥ 2.5 ns Resolution 1 bit Horizontal 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Main Time Base Range 54830B/D, 54831B/D 54832B/D, 54833A/D 500 ps/div to 20 s/div 200 ps/div to 20 s/div Horizontal Position Range 0 to ± 200 s Delayed Sweep Range 1 ps/div to current main time base setting Resolution 4 ps Timebase Accuracy 15 ppm (±0.0015%) Delta-Time Measurement Accuracy 54830B/D, 54831B/D 54832B/D, 54833A/D ≥ 256 Averages, RMS 500 fs rms 400 fs rms ≥ 256 Averages, Peak ±[(2.2 ps) + (15x10-6 x |reading|)] peak ±[(2.0 ps) + (15x10 -6 x |reading|)] peak Average Disabled, RMS 10 ps rms 7 ps rms Average Disabled, Peak ±[(35 ps) + (15x10-6 x |reading|)] peak ±[(25 ps) + (15x10 -6 x |reading|)] peak Channel-to-Channel Deskew Range –100 µs to 100 µs Modes Main, Delayed, Roll Reference Positions Left, Center, Right Jitter Measurement Floor 54830B/D, 54831B/D 54832B/D, 54833A/D Time Interval Error 7 ps rms 5 ps rms Period Jitter 10 ps rms 7 ps rms N-Cycle, Cycle-Cycle Jitter 15 ps rms 11 ps rms Performance Characteristics continued
Acquisition: Analog Channels 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Real Time Sample Rate (Max)
2 Channels Interleaved 4 GSa/s
Equivalent Time Sample Rate (Max) 250 GSa/s Memory Depth Interleaved/each channel Standard 4 M / 2 M (1 M / 500 K for 54833A) Option 040 8 M / 4 M Option 080 16 M / 8 M Option 160 32 M / 16 M Option 320 64 M / 32 M Option 640 128 M / 64 M Sampling Modes Real Time Normal Successive single-shot acquisitions Peak Detect Captures and displays narrow pulses or glitches at all real time sample rates Hi Resolution Real-time boxcar averaging reduces random noise and increases resolution Equivalent Time Random repetitive sampling (higher time resolution at faster sweep speeds) Segmented Memory10 Captures bursting signals at maximum sample rate without consuming memory during periods of inactivity. Selectable number of segments up to 32,000 depending on memory option installed. Typical minimum inter-segment time (or the time between acquisitions) of 20 µs. Averaging Selectable from 2 to 4096 Filters Sin[x])/x Interpolation Filter On/Off selectable FIR digital filter. Digital signal processing adds points between acquired data points to enhance measurement accuracy and waveform display quality. BW= Sample Rate/4 Acquisition: Digital Channels (54830D/31D/32D/33D only) Maximum Real Time Sample Rate 1 GSa/s Memory Depth per Channel 32 M Minimum Width Glitch Detection 2.5 ns Performance Characteristics continued
Trigger 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Sensitivity Internal8 DC to 600 MHz: 0.6 div 600 MHz to 1 GHz: 1.5 div (50 Ω) External DC to 100 MHz: 0.05 x (signal range) 100 MHz to 600 MHz: 0.10 x (signal range) (54830B/D, 54833A/D) 600 MHz to 1 GHz: 0.18 x (signal range) (54833A/D) Auxiliary DC to 600 MHz: 300 mVp-p (54831B/31D/32B/32D/33A/33D) Level Range Internal ± 8 div from center screen (1 M Ω) ± 8 div from center screen (50 Ω) External ± 1 V, ± 5 V, ± 25 V (1 MΩ) Auxiliary ± 5 V (54831B/32B/31D/32D/33A/33D) Sweep Modes Auto, triggered, single Trigger Coupling DC, AC, low frequency reject (50 kHz high pass filter), high frequency reject (50 kHz low pass filter) Trigger Conditioning Noise reject adds hysteresis to trigger circuitry decreasing sensitivity to noise Trigger Holdoff Range 80 ns to 320 ms (54830A/B Series) 50 ns to 10 s (54830D Series) Trigger Jitter 8 ps ± 0.05 ppm x |delay setting| rms Trigger Actions Specify an action to occur, and the frequency of the action, when a trigger condition occurs. Actions include: e-mail on trigger and QuickMeas+ Trigger Modes Edge Triggers on a specified slope and voltage level on any channel, auxiliary trigger (4 channel models), external trigger (2 channel models) or line input. Glitch Triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. Minimum glitch width is 500 ps (analog channels) or 2.5 ns (digital channels on 54830D/31D/32D/33D). Glitch range settings: <1.5 ns to <160 ms (54830A/B Series), <1.5 ns to <10 s (analog channels on 54830D/31D/32D/33D), <5 ns to <10 s (digital channels on 54830D/31D/32D/33D) Line Triggers on the line voltage powering the oscilloscope. Pattern Triggers when a specified logical combination of the channels is entered, exited, is present or absent for a specified period of time or is within a specified time range. Each channel can have a value of High (H), Low (L) or Don’t care (X). State Pattern trigger clocked by the rising or falling edge of one channel. Logic type: AND or NAND. Delay by Time The trigger is qualified by an edge. After a specified time delay between 30 ns to 160 ms (5 ns to 10 s for 54830D/31D/32D/33D) a rising or falling edge on any one selected input will generate the trigger. Delay by Events The trigger is qualified by an edge. After a specified delay between 1 to 16,000,000 rising or falling edges on any one selected input will generate the trigger. TV Trigger on one of the three standard television waveforms: 525 lines/60 Hz (NTSC) 625 lines/50 Hz (PAL), or define a custom waveform Violation Triggers Pulse Width See Trigger Mode Glitch for performance characteristics. Setup/Hold Triggers on setup, hold or setup and hold violations in your circuit. Requires a clock and data signal on any two input channels as trigger sources. High and low thresholds and setup and/or hold time must then be specified. Transition Trigger on pulse rising or falling edges that do not cross two voltage levels in > or < the amount of time specified. Performance Characteristics continued
Trigger: Digital Channels (54830D/31D/32D/33D only) Threshold Range (user defined) ±8.0 V in 10 mV increments Threshold Accuracy* ±(100 mV + 3% of threshold setting) ECL=–1.3 V, PECL=3.7 V Measurements and Math 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Waveform Measurements Voltage (analog channels only) Peak-to-Peak, Minimum, Maximum, Average, RMS, Amplitude, Base, T op, Overshoot, Preshoot, Upper, Middle, Lower, Area Time (all channels) Period, Frequency, Positive Width, Negative Width, Duty Cycle, Delta Time (analog channels only) Rise Time, Fall Time, Tmin, Tmax, Channel-to-Channel Phase Frequency Domain FFT Frequency, FFT Magnitude, FFT Delta Frequency, FFT Delta Magnitude Eye Pattern Eye Height, Eye Width, Jitter, Crossing %, Q-Factor, Duty Cycle Distortion Measurement Modes Automatic Measurements Measure menu access to all measurements, 4 measurements can be displayed simultaneously QuickMeas+ Front panel button activates five pre-selected or five user defined automatic measurements Drag and Drop Measurement T oolbar Measurement toolbar with common measurement icons that can be dragged and dropped onto the displayed waveforms Statistics Displays the mean, standard deviation, minimum and maximum measurement values for the displayed automatic measurements Histograms (analog channels only) Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined using waveform markers. Measurements included: mean, standard deviation, peak-to-peak value, median, total hits, peak (area of most hits), and mean ± 1,2, and 3 sigma Eye Diagram Measurements Eye diagram display mode allows triggering on both negative-going and positive-going edges of a signal. Eye diagram measurements include eye height, eye width, jitter, crossing percentage, Q factor, and duty cycle distortion Mask T esting Allows pass/fail testing to user-defined or Agilent-supplied waveform templates. AutoMask allows user to create a mask template from a captured waveform and define tolerance range in time/voltage or percentage. T est modes include test forever, test to specified time or event limit, and stop on failure. Communications Mask T est Kit Option provides a set of ITU-T G.703, ANSI T1.102, and IEEE 802.3 industry standard masks for compliance testing Marker Modes Manual Markers, Track Waveform Data, Track Measurements Waveform Math 4 functions f1-f4. Select from Add, Average, Differentiate, Divide, FFT Magnitude, FFT Phase, High Pass Filter, Integrate, Invert, Low Pass Filter, Magnify, Min, Max, Multiply, Subtract, Versus FFT Frequency Range6 DC to 2 GHz (2 channels interleaved), DC to 1 GHz (each channel) Frequency Resolution Resolution = Sample Rate / Memory Depth Best resolution at maximum sample rate 4 GSa/s / 16 M = 250 Hz Frequency Accuracy (1/2 frequency resolution)+(5x10-5)(signal frequency) Signal-to-Noise Ratio9 80 dB at 1 Mpts memory depth Window Modes Hanning, Flattop, Rectangular Performance Characteristics continued
Display, Computer System and Peripherals, I/O Ports 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D Display 8.4 inch diagonal color TFT-LCD Resolution 640 pixels horizontally x 480 pixels vertically Annotation Up to 12 labels, with up to 100 characters each can be inserted into the waveform area Waveform Styles Connect Dots, Dots, Persistence (minimum, variable, infinite), Color Graded Infinite Persistence Simultaneous Grids 1, 2, or 4 Display Update Rate7 Standard Waveforms/second > 3,100 Standard Vp-p Measurements/second > 190 Maximum Waveforms/second > 8,800 Maximum Vp-p Measurements/second > 200 Deep Memory Waveforms/second > 50 Deep Memory Vp-p > 10 Measurements/second Computer System and Peripherals CPU Intel Pentium® III 1 GHz microprocessor CPU Memory 512 MB Drives ≥20 GB internal hard drive, CD-ROM drive on rear panel, LS-120 Superdisk floppy drive reads/writes from/to both standard 3.5 inch 1.44 MB and 120 MB disks Peripherals Logitech optical USB mouse and condensed keyboard supplied. All Infiniium models support any Windows compatible input device with a serial, PS/2 or USB interface File T ypes Waveforms Internal Y values; X and Y values in ASCII or Microsoft Excel formats Images BMP, PCX, TIFF, GIF or JPEG I/O Ports LAN RJ-45 connector, supports 10Base-T and 100Base-T. Enables Web-enabled remote control, e-mail on trigger or demand, data/file transfers and network printing GPIB IEEE 488.2, fully programmable RS-232 (serial) COM1, printer and pointing device support Parallel Centronics printer port PS/2 2 ports. Supports PS/2 pointing and input devices USB 2 ports. Allows connection of USB peripherals and pointing devices while the oscilloscope is on Video Output 15 pin VGA, full color Auxiliary Output DC (±2.4 V); square wave (715 Hz[±15%], [±5%]); trigger output (255 mV p-p into 50 Ω) TTL Output TTL compatible signal Performance Characteristics continued
General Characteristics 54830B, 54831B, 54832B, 54833A, 54830D, 54831D, 54832D and 54833D T emperature Operating 0°C to + 50°C Non-operating –40°C to + 70°C Humidity Operating Up to 95% relative humidity (non-condensing) at +40°C Non-operating Up to 90% relative humidity at +65°C Altitude Operating Up to 4,600 meters (15,000 feet) Non-operating Up to 15,300 meters (50,000 feet) Vibration Operating Random vibration 5-500 Hz, 10 minutes per axis, 0.3 g(rms) Non-operating Random vibration 5-500 Hz, 10 minutes per axis, 2.41 g(rms); resonant search 5-500 Hz, swept sine, 1 octave/minute sweep rate, (0.75g), 5 minute resonant dwell at 4 resonances per axis Power 100-240 VAC, ± 10%, Cat II, 47 to 440 Hz; Max power dissipated: 390 W Weight Net: 13.4 kg (29.5 lbs.) Shipping: 16.4 kg (36.1 lbs.) Dimensions (excluding handle) Height: 216 mm (8.5 in); Width: 437 mm (17.19 in); Depth: 440 mm (17.34 in) Safety Meets IEC1010-1 +A2, CSA certified to C22.2 No.1010.1, Self certified to UL 3111 * Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10°C from firmware calibration temperature. 1 T ypical system bandwidth for 54830 Series in 1 M Ω input with standard 1165A passive probe attached is 600 MHz. 2 Rise time figures for 54830 Series are calculated from t r = 0.35/bandwidth. 3 54830B/31B/32B/33A/30D/31D/32D/33D: Magnification is used below 5 mV/div range. Below 5 mV/div, full scale is defined as 40 mV . Full scale is defined as the major attenuator setting above an intermediate setting. (Major settings 50 Ω: 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 1 MΩ: all of the above plus 2 V). 4 Vertical resolution for 8 bits = 0.4% of full scale, for 12 bits = 0.024% of full scale. 5 The dc gain accuracy decreases 0.08% of full scale per degree C from the firmware calibration temperature. 6 FFT amplitude readings are affected by input amplifier roll-off 54830/31B/D (–3 dB at 600 MHz, with amplitude decreasing as fr equency increases above 600 MHz), 54832B/32D/33A/33D: (–3 dB at 1 GHz, with amplitude decreasing as frequency increases above 1 GHz). 7 Standard measurement condition: Real time mode, 512 pts memory, minimum persistence display mode, triggered sweep mode, no int erpolation, markers off, math off, connect dots off, 1 channel acquisition, 50 ns/div, only analog channels on (for 54830D models). Maximum condition is the same as standard condition except time/div is set to 1 ns/div. Deep memory condition is the same as standard condition except time/div is set to 200 µs/div and memory depth is set to 8 Mpts per channel. 8 For 54830B Series specification valid for vertical ranges > 5 mV / div. 9 Noise floor varies as memory depth increases with averaging on. 10 Standard feature with version A.03.70 system software or higher, but only available on 54830B/31B/32B models with serial numb er MY41003401 or greater, 54830D/31D/32D models with MY42001701 or greater, or 54833A/33D models with MY43000601 or greater. Performance Characteristics continued
If your need is short term, turn to our Preferred Rental Partners (PRPs) to rent equipment for up to 12 months. Our PRPs offer you the latest Agilent equipment and configuration options, along with fast delivery and exceptional service. For details, contact your closest PRP. Electro Rent (US) www.electrorent.com/agilent 888-893-5996 TRS (US) www.trsonesource.com/agilent 877-610-5010 Microlease (Europe) www.microlease.com/agilent +44 (0) 20 84 200 200 Trade-Up Do you already own an Infiniium oscilloscope? Capitalize on your previous investment by trading it in for a substantial credit on a new model with advanced deep memory or more bandwidth. Our trade-up program helps you stretch your equipment budget and better manage your assets while upgrading to the latest solutions. We also offer special promotions that make it easier than ever for you to acquire the latest technologies. Contact your local Agilent representative to find the Infiniium that’s right for you and the best option for acquiring it. http:/ /buyalternatives.tm.agilent.com The Infiniium scope you buy today must also meet your per- formance requirements for tomorrow. Ensure that your equipment can handle your future needs with the right scope and purchasing plan. Before you select the Infiniium scope that’s right for you, consider these flexible purchasing options, so you can get the best tools for the job, regardless of your company’s financial constraints. Lease and Finance If you’d like to improve your balance sheet by expensing equipment costs, or your budget won’t cover the purchase price up front, consider our leasing and financing plans. We offer many flexible options: select the term you need, choose from various paths for end of term, and even revise your plan to include eligible upgrades and add-ons. Contact your local Agilent Financial Services Center for details. Flexible purchasing alternatives help you acquire the instruments you need
Agilent Model Channels Bandwidth Sample Rate Standard Memory Depth 54830D 2+16 600 MHz 54831D 4+16 600 MHz 54832D 4+16 1 GHz 54833D 2+16 1 GHz 54830B 2 600 MHz 54831B 4 600 MHz 54832B 4 1 GHz 54833A 2 1 GHz The above models include: Optical USB Mouse, Condensed Keyboard, User's Quick Start Guide in English language (other languages also available), Documentation CD (Service Guide, Programmer’s Guide), Information System in English language, accessory pouch (54810-68701), front panel cover, power cord, and one-year warranty. Ordering Information and Configuration
4 GSa/s (interleaved = CH/2)
2 GSa/s on each channel
4 M (interleaved = CH/2)
2 M on each channel
Agilent Model Passive Probes Logic Cable Kit 54830D 1165A 10:1 10 M Ω probes (Qty 2) 54826-68701 MSO logic cable kit (Qty 1) 54831D 1165A 10:1 10 M Ω probes (Qty 4) 54826-68701 MSO logic cable kit (Qty 1) 54832D* None 54826-68701 MSO logic cable kit (Qty 1) 54833D* None 54826-68701 MSO logic cable kit (Qty 1) 54830B 1165A 10:1 10 M Ω probes (Qty 2) None 54831B 1165A 10:1 10 M Ω probes (Qty 4) None 54832B* None None 54833A* None None * Passive probes not included, please order option 001, 002, 004, or active probe option 012, 019 (for 54832B/D, 54833A/D).
1 M (interleaved = CH/2)
500 K on each channel
For information about higher bandwidth scope and probing solutions up to 13 GHz of system bandwidth, please visit our web site at www.agilent.com/find/infiniimax New 54852A, 2 GHz bandwidth,
10 GSa/s sample rate per channel
affordably priced. More information available at www.agilent.com/find/infiniimax
Acquisition Memory Options (for analog channels only) 040 8 Mpts on half the acquisition channels (interleaved) or 4 Mpts on each acquisition channel 080 16 Mpts on half the acquisition channels (interleaved) or 8 Mpts on each acquisition channel 160 32 Mpts on half the acquisition channels (interleaved) or 16 Mpts on each acquisition channel 320 64 Mpts on half the acquisition channels (interleaved) or 32 Mpts on each acquisition channel 640 128 Mpts on half the acquisition channels (interleaved) or 64 Mpts on each acquisition channel N2845A* After-purchase memory upgrade to obtain 4 Mpts/ch, 8 Mpts max N2846A* After-purchase memory upgrade to obtain 8 Mpts/ch, 16 Mpts max * Users can install upgrades without opening the instrument case or requiring on-site service. Probe Options
001 Add two 1165A, 10:1 passive probes for the 54830 Series
002 Add one 1162A 1:1 passive probe
004 Add four 1165A, 10:1 passive probes for the 54830 Series
005 Add one 54826-68701 logic probe kit
(This probe kit comes standard with the 54830D/31D/32D/33D) 007 Add one Wedge adapter kit (1 each 3/8/16 signals, 0.5 mm)
008 Add one 1153A 200 MHz differential probe
011 Add one 1155A 2 Channel, 750 MHz active probe
012 Add one 1156A 1.5 GHz active probe 016 (E2654A) EZ-Probe‚ Positioner: includes base, joystick, and articulating arm 017 ≥ 20 GB removable hard disk drive. Replaces ≥ 20 GB internal hard disk with a ≥ 20 Gb removable hard disk. Order the N5390A for additional hard disk drive cartridges that contain the full Windows operating system and oscilloscope application. 1130A 1.5 GHz InfiniiMax probe amplifier – NO PROBE HEADS INCLUDED † E2675A InfiniiMax differential browser probe head kit E5396A Half-Size (17 channel) Soft touch connecterless Logic Probe for MSO models † For a complete probing solution, also order a connectivity kit or individual probe head(s). Recommend E2675A differential brow ser probe head. Instrument Options N5383A Infiniium Performance Upgrade Kit for Infiniium 54830 Series oscilloscopes. Required to upgrade system software from A.02.xx (Windows 98) to A.03.xx or higher (Windows XP Pro) 006 (E2699A) My Infiniium Integration Package Option 003 (N5384A) High-Speed Serial Data Analysis Software Option 021 (N5391A) Low-Speed Serial Data Analysis Software Option 015 (E2681A) EZJIT Jitter Analysis Software Option Ordering Information and Configuration: Agilent Infiniium Options
Ordering Information and Configuration: Agilent Infiniium Options continued Options Description Instrument Options (continued) E2690A ADV-1 Advanced Time Interval and Jitter Analysis (one scope license) (US and Canada) N5385A ADV-1 (International) E2691A ADV-4 Advanced Time Interval and Jitter Analysis (four scope licenses) (US and Canada) N5386A ADV-4 (International) E2692A BAS-1 Basic Time Interval and Jitter Analysis (one scope license) (US and Canada) N5387A BAS-1 (International) E2693A ADV-SA Subscription for one-year advanced product updates (US and Canada) N5388A ADV-SA (International) E2694A BAS-SA Subscription for one-year basic product updates (US and Canada) N5389A BAS-SA (International) N5397A FPGA Dynamic Probe for Infiniium Mixed-Signal Oscilloscopes N5392A Ethernet Electrical Performance Validation and Compliance Software N5395A Ethernet Electrical Compliance T est Fixture N5396A Gigabit Ethernet Jitter T est Cable E2698A Ethernet Masks Option USB 2.0 T est Option E2645A for 54800A Series N2855A for 54830B/D Series with software version A.02.xx E2683A for 54830B/D Series, 54833A and 54850A Series with software version A.03.10 or higher E2646A Additional USB 2.0 SQiDD T est Fixture E2625A Communication Mask T est Kit Option VoiceControl Option (English only) E2635A for 54800A Series N2850A for 54830B/D Series with software version A.02.xx E2682A for 54830B/D Series and 54850A Series with software version A.03.10 or higher 1CM (E2609B) Add one rackmount kit 1184A T estmobile with keyboard and mouse tray, drawer for accessories E5850A Time-correlation fixture, link Infiniium scope to logic analyzer Manual Options OB3 Printed service manual OBF Printed programmer’s manual AB2 Printed user’s quick start guide in simplified Chinese ABJ Printed user’s quick start guide in Japanese Service Options A6J ANSI Z540-compliant calibration
Publication Title Publication Type Publication Number Agilent T echnologies Digital and Mixed Signal Oscilloscopes Selection Guide 5988-8460EN/ENUS Infiniium 80000 Series Oscilloscopes and InfiniiMax II Series Probes Data Sheet 5989-1487EN/ENUS Infiniium 54850 Series Oscilloscopes and InfiniiMax 1130 Series Probes Data Sheet 5988-7976EN/ENUS Infiniium 54800 Series Oscilloscope Probes, Accessories and Options Data Sheet 5968-7141EN/ENUS N5397A FPGA Dynamic Probe for Infiniium Mixed-Signal Oscilloscopes Data Sheet 5989-1848EN N5400A EZJIT Plus Jitter Analysis Data Sheet 5989-0109EN E2681A EZJIT Jitter Analysis Software Data Sheet 5989-0109EN E2690A Time Interval and Jitter Analysis Software Data Sheet 5988-9723EN E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software Data Sheet 5989-0108EN N5391A Low-Speed Serial Data Analysis Software Data Sheet 5989-1250EN 89601A Infiniium Oscilloscopes and 89601A Vector Signal Analysis Software Data Sheet 5989-0947EN N5393A PCI Express Electrical Performance Validation and Compliance Software Data Sheet 5989-1240EN N5392A Ethernet Electrical Performance Validation and Compliance Software Data Sheet 5989-1527EN USB 2.0 Compliance T est Software Data Sheet 5989-0236EN E2625A Communication Mask T est Kit and E2698A Ethernet Masks Data Sheet 5989-0372EN E2699A My Infiniium Integration Software Data Sheet 5988-9934EN Agilent Mixed Signal Oscilloscopes: 6-minute Video Demonstration Video CD 5988-9288EN
Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. T wo concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.” Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifica- tions and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product opera- tion, and provide basic measurement assis- tance for the use of specified capabilities, at no extra cost upon request. Many self- help tools are available. www.agilent.com 1 800 829 4444 Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can pur- chase according to your unique technical and business needs. Solve problems effi- ciently and gain a competitive edge by con- tracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on- site education and training, as well as design, system integration, project manage- ment, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instru- ments and systems, and obtain dependable measurement accuracy for the life of those products. For more information on Agilent T echnologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Or contact the test and measurement experts at Agilent T echnologies: 1 800 829 4444 (8am-8pm EST) Product specifications and descriptions in this document subject to change without notice. © Agilent T echnologies, Inc., 2004 Printed in USA November 17, 2004 5988-3788EN Windows is a U.S. registered trademark of Microsoft Corp. Java is a U.S. trademark of Sun Microsystems, Inc. M ATLAB is a U.S. registered trademark of The Math Works, Inc. Pentium is a U.S registered trademark of Intel Corporation Intel is a U.S. registered trademark of Intel Corporation EZ-Probe Positioner is a U.S. registered trademark of Cascade Microtech, Inc. Instrument Viewer is a U.S. registered trademark of MicroOptical Corporation Visual Studio is a U.S. registered trademark of Microsoft Corp. LabView is a U.S. registered trademark of National Instruments TMControl is a trademark of L-3 Analytics Corporation www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Direct