54600-Series Oscilloscopes Data Sheet Multiple configurations to meet your needs If you work with both analog and digital components, Agilent Technologies 54600-Series oscilloscopes can help you easily see more of what's going on in your designs. The unique 2 + 16-channel mixed signal oscillo- scope (MSO) models and the tra- ditional 2- and 4-channel models are optimized with just the capa- bilities you need for verifying and debugging designs that include A/Ds, D/As, DSPs, and embedded 8- or 16-bit microcontrollers. These scopes give you the tools you need to solve your mixed analog and digital engineering challenges more easily. Ideal for mixed analog and digital analysis Ideal for analyzing designs with both analog and digital com- ponents, the 54600-Series scopes combine three critical features:
- Up to 8 MB of MegaZoom deep memory come standard so you can capture long, non-repeat- ing signals, maintain high sam- ple rate, and quickly zoom in on areas of interest
- A revolutionary ultra-respon- sive, high-definition display that lets you see more signal detail than ever before
- Flexible triggering that lets you easily isolate and analyze the complex signals and fault conditions common in mixed analog and digital designs. I2C, CAN, LIN, USB, and SPI triggering come standard. N2758A CAN trigger module option is also available. This combination of capabilities is tailored to give you the meas- urement power you need to get your mixed analog and digital job done faster. At Agilent Technologies, we focus on developing products that help you do your job better. That’s why 54600-Series scopes are optimized for your needs. Choose the one that’s right for your application and your budget. Easily see what's happening in your mixed analog and digital designs 60 to 500 MHz, up to 2 GSa/s Unique 2 + 16-channel MSO and 2- or 4-channel models
4 MB to 8 MB MegaZoom deep
Flexible triggering including CAN, I2C, LIN, SPI, and USB
- Deep memory transfer over the interface bus
Figure 1. 2 + 16-channel mixed signal oscilloscope (MSO) family shown with 2- and 4-channel models.
60 MHz
200 MSa/s
100 MHz
350 MHz
2 GSa/s*
500 MHz
Maximum sample rate and memory are interleaved; deep memory is standard, no options needed.
Figure 2. 2 + 16-channel mixed signal oscilloscope (MSO) allows you to view analog and digital content on one instrument. to see a few channels at a time. display, and flexible triggering. see details in your designs.
memory is not a special mode. memory at an affordable price. Figure 3. The bright dot on the high-definition display is a distortion in 1 of the 1,500 is not a special mode; it is available on every measurement pass at full speed.
representation of your signals.
- Parallel and RS-232 interfaces make connection to printers and PCs a snap. And the 54600-Series scopes come with standard parallel and RS-232 interfaces on the rear panel. For faster data transfers, an optional GPIB interface module is also available.
- IntuiLink, a free software applica- tion, simplifies PC connectivity when you need to transfer images and waveform data to your PC. IntuiLink lets you focus more time on design issues rather than on program- ming. With the click of a but- ton on IntuiLink’s toolbar, you can download data or insert a snapshot of an oscilloscope screen directly into your Microsoft® Excel spreadsheets or Word documents, or save the image as a bitmap file. Once the data is in an Excel spreadsheet, you can leverage Excel’s extensive analysis functions to create custom graphs and views. For more information on IntuiLink, please see the IntuiLink datasheet with Agilent publication number 5980-3115EN or visit the URL www.agilent.com/find/intuilink Built-in floppy drive A built-in 1.44 MB floppy drive makes it easy for you to store waveform data, screen images, and scope setups. You can store your waveform images as TIF or BMP files and your waveform data as ASCII files for easy import into other PC applica- tions. If you share your lab equip- ment with others, you can save your measurement setups and traces to diskette, making it sim- ple to reproduce your every-day setups as well as your advanced configurations. Built-in help at your fingertips An innovative built-in help system in 11 different languages (English, French, German, Spanish, Italian, Japanese, Korean, Traditional Chinese, Simplified Chinese, Russian, and Portuguese) gives you quick access to the help you need. If you have a question about a par- ticular feature, simply press and hold the corresponding front- panel key for a few seconds, and a help screen pops up to explain its function. You’ll no longer have to look for the manual when you need assistance setting up scope functions or making complex measurements.
Figure 4. Press and hold any key for built-in Help, such as this description of the frequency measurement.
Transfer all of your data over the bus, even when using deep memory. Typical transfer time is <70 seconds for 2 MB of data over GPIB. The 54640-Series requires soft- ware revision 1.0 or later. The 54620-Series requires software revision 1.5 or later. The system software is stored in FLASH ROM that can be upgraded easily from a built-in floppy disk drive in the scope. Visit the 54620-Series customer web site at: www.agilent.com/find/5462xsw for a free copy of the system software and the IntuiLink Data Capture application to pull the data out of the scope to the PC. Other standard features
- Waveform math with FFTs: Analysis functions include -, *, Integrate, and Differentiate, as well as Fast Fourier Transforms.
- 1-ns peak detect on the 54640-Series and 5-ns peak detect on the 54620-Series means you won’t have to worry about missing narrow glitches.
- Autoscale lets you quickly dis- play any active signals, auto- matically setting the vertical, horizontal and trigger controls for the best display.
- Printer connectivity is easy for HP Deskjets, Laserjets, Epson, or integrated thermal printer option with the stan- dard parallel port on the rear panel.
- High resolution mode offers up to 12 bits of resolution in real-time (single-shot) modes, reducing noise. This is accom- plished by averaging sequential data points and mapping the average to the display when at slow sweep speeds.
- 1-year warranty: All 54600-Series scopes include a full 1-year warranty with optional 3-year and 5-year warranty coverage.
- Money-back guarantee: Get a full refund if you’re not satis- fied with your purchase for any reason. See page 24 for more information. Affordable and Responsive (continued)
Trigger on CAN 2.0A/B message frames with user specified IDs and/or data Trigger on Error frames Differential CAN Acknowledge On/Off Built In QuickHelp Remote Control via GPIB/RS232 Compatible with 54621D, 54622D, 54641D, 54642D The N2758A CAN trigger module extends your Mixed Signal Oscilloscope’s (MSO) capabilities beyond the standard CAN SOF trigger. The module enables the MSO to isolate and trigger on a particular frame’s content. This triggering allows you to:
- sort through frame traffic on the bus
- isolate frames of interest
- specify particular frame characteristics
- trigger and measure latency between CAN frames meeting the user specification The CAN trigger module is ideal for analyzing all traffic on the broadcast network. Quickly find frames that meet the specifica- tions you select with an isolating capability similar to pattern triggering across multiple channels in the parallel domain. Synchronize to the particular frame then examine the system behavior of interest. For more comprehensive information, please see the Agilent 54600-Series Oscilloscopes Probes and Accessories data sheet (Agilent publication number 5968-8153). You can get a copy by visiting our website at: www.agilent.com/find/mso The N2758A kit includes the CAN trigger module, digital cable, ten grabbers, and two probe ground leads. The N2758A CAN trigger module reduces the time required to debug your mixed signal CAN based designs.
MegaZoom deep memory helps you determine how your signals are impacting each other. With shallow memory scopes, you have to choose whether you look at a slow analog signal or fast digital content. With up to 8 MB deep memory, you don’t have to choose – capture all of your data at once. Revolutionary high-definition display reveals subtle details that most scopes won’t show you. Standard RS-232 and parallel ports provide PC and printer connectivity. Free IntuiLink PC software makes transfer of waveform data to PC fast and easy. Intensity knob allows you to adjust the contrast on screen. Built-in floppy drive makes it easy to save your work and update your system software.
analysis with MegaZoom’s instant response and optimum resolution. Autoscale lets you quickly display any active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while opti- mizing memory. QuickMeas gives you any three automated measurements with the push of a button. QuickPrint automatically prints your screen or saves to disk with automated file names. Standard Serial Triggering includes CAN, I2C, LIN, SPI, and USB Built-in help is available in 11 languages. Simply press and hold the front-panel key of interest for a few seconds, and a help screen pops up to explain its function. Maximum sample rate and resolution on every measure- ment. The scope automatically adjusts memory depth as you use it, so you get maximum sample rate and resolution on every measurement. You don’t even have to think about it. 2 analog and 16 digital channel MSOs allow you to see up to 18 time-aligned signals on your scope screen. Also available in 2- and 4-channel models.
To get the most out of your scope, you need the right probes and accessories for your particular application. That's why Agilent Technologies offers a complete family of innovative probes and 54600-Series scopes. For more comprehensive information, please see the Agilent 54600-Series Oscilloscopes Probes and Accessories data sheet (Agilent publication number 5968-8153). You can get a copy by visiting our website at: www.agilent.com/find/mso Agilent Passive Probes Selection Guide 10070C 10073C (shipped 10074C (shipped 10076A N2771A with 54640-Series) with 54620-Series) high-voltage probe high-voltage probe Probe Bandwidth
20 MHz
150 MHz
250 MHz
50 MHz
Probe Risetime (Calculated) < 17.5 ns < 700 ps < 2.33 ns < 1.4 ns < 7 ns Attenuation Ratio 1:1 10:1 10:1 100:1 1000:1 Input Resistance 1 MΩ 2.2 MΩ 10 MΩ 66.7 MΩ 100 MΩ (when terminated into 1 MΩ) Input Capacitance Approx. 70 pF Approx. 12 pF Approx. 15 pF Approx. 3 pF Approx. 1 pF Maximum Input
400 Vpk CAT I
500 Vpk CAT I
4000 Vpk
15 kV dc, 10 kVrms (dc + peak ac) (mains isolated) (mains isolated) (mains isolated) 30 kV dc + peak ac
400 Vpk CAT II
(post receptacle (post receptacle (post receptacle mains) mains) mains) Compensation Range None 6 - 15 pF 9 - 17 pF 6 - 20 pF 7 - 25 pF Probe Sense No Yes Yes Yes No Current Probes
Description
100 kHz current probe, ac/dc N2774A
50 MHz current probe, ac/dc
20 MHz differential probe
Differential probe power supply
Performance Characteristics Acquisition: Analog Channels Max Sample Rate 54621A/D, 54622A/D, 54624A: 200 MSa/s 54641A/D, 54642A/D: 2 GSa/sec interleaved, 1 GSa/sec each channel Max Memory Depth 54621A/D, 54622A/D, 54624A: 4 MB interleaved, 2 MB each channel 54641A/D, 54642A/D: 8 MB interleaved, 4 MB each channel Vertical Resolution 8 bits Peak Detection 54621A/D, 54622A/D, 54624A: 5 ns 54641A/D, 54642A/D: 1 ns @ max sample rate Averaging Selectable from 2, 4, 8, 16, 32, 64 … to 16383 High Resolution Mode 54621A/D, 54622A/D, 54624A: 12 bits of resolution when ≥500 µs/div, (average mode with ave = 1) 54641A/D, 54642A/D: 12 bits of resolution when ≥100 µs/div, (average mode with ave = 1) Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of scope, whichever is less) with vectors on. Acquisition: Digital Channels (54621D, 54622D, 54641D, and 54642D only) Max Sample Rate 54621D, 54622D: 400 MSa/s interleaved, 200 MSa/s each channel 54641D, 54642D: 1 GSa/s Max Memory Depth 54621D, 54622D: 8 Mb interleaved, 4 Mb ea. channel 54641D, 54642D: 4 Mb Vertical Resolution 1 bit Glitch Detection 5 ns (min pulse width) Vertical System: Analog Channels Analog Channels 54621A/D, 54622A/D, 54641A/D, 54642A/D: Ch 1 and 2 simultaneous acquisition 54624A: Ch 1, 2, 3 and 4 simultaneous acquisition Bandwidth (-3dB)* 54621A/D: dc to 60 MHz 54622A/D, 54624A: dc to 100 MHz 54641A/D: dc to 350 MHz 54642A/D: dc to 500 MHz ac Coupled 54621A/D: 3.5 Hz to 60 MHz 54622A/D: 54624A: 3.5 Hz to 100 MHz 54641A/D: 3.5 Hz to 350 MHz 54642A/D: 3.5 Hz to 500 MHz Calculated Risetime 54621A/D: ~5.8 ns (=0.35/bandwidth) 54622A/D, 54624A: ~3.5 ns 54641A/D: ~1.0 ns 54642A/D: ~700 ps Single Shot Bandwidth 54621A/D, 54622A/D, 54624A: 50 MHz 54641A/D: 350 MHz maximum 54642A/D: 500 MHz maximum Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Vertical System: Analog Channels (continued) Range1,2 54621A/D, 54622A/D, 54624A: 1 mV/div to 5 V/div 54641A/D, 54642A/D: 2 mV/div to 5 V/div Maximum Input CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
5 Vrms with 50 Ωinput
54621A/D, 54622A/D, 54624A: ±5 V on ranges <10 mV/div; ±25 V on ranges 10 mV/div to 199 mV/div; ±100 V on ranges ≥200 mV/div 54641A/D, 54642A/D: ±5 V on ranges <10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div; ±75 V on ranges >200 mV/div Dynamic Range Lesser of ±8 div or ±32 V from center screen Input Resistance 54621A/D, 54622A/D, 54624A: 1 MΩ±1% 54641A/D, 54642A/D: 1 MΩ±1%, 50 Ωselectable Input Capacitance 54621A/D, 54622A/D, 54624A: ~ 14 pF 54641A/D, 54642A/D: ~ 13 pF Coupling 54621A/D, 54622A/D, 54624A: ac, dc, ground 54641A/D, 54642A/D: ac, dc BW Limit 54621A/D, 54622A/D, 54624A: ~ 20 MHz selectable 54641A/D, 54642A/D: ~ 25 MHz selectable Channel-to-Channel Isolation 54621A/D, 54622A/D, 54624A: dc to 20 MHz > 40 dB; 20 MHz to max bandwidth > 30 dB (with channels at same V/div) 54641A/D, 54642A/D:DC to max bandwidth >40 dB Probes 54621A/D, 54622A/D, 54624A: 10:1 10074C shipped standard for each analog channel 54641A/D, 54642A/D: 10:1 10073C shipped standard for each analog channel Probe ID (Agilent/HP and Auto probe sense Tek compatible) ESD Tolerance ±2 kV Noise Peak-to-Peak 54621A/D, 54622A/D, 54624A: 2% full scale or 1 mV, whichever is greater 54641A/D, 54642A/D: 3% full scale or 3 mV, whichever is greater Common Mode Rejection Ratio 20 dB @ 50 MHz DC Vertical Gain Accuracy*1,2 ±2.0% full scale DC Vertical Offset Accuracy 54621A/D, 54622A/D, 54624A: 54641A/D, 54642A/D: Single Cursor Accuracy1,2 ±{DC Vertical Gain Accuracy + DC Vertical Offset Accuracy + 0.2% full scale (~1/2 LSB) } 54621A/D, 54622A/D, 54624A example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, Dual Cursor Accuracy*1,2 ±{DC Vertical Gain Accuracy + 0.4% full scale (~1 LSB)} Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0%(80 mV) + 0.4%(80 mV)} = ±1.92 mV Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature. For 54621A, 54621D, 54622A, 54622D, and 54624A, 1 mV/div is a magnification of 2 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting. For 54641A, 54641D, 54642A, and 54642D, 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting.
Performance Characteristics (continued) Vertical System: Digital Channels (54621D, 54622D, 54641D, and 54642D only) Number of Channels
16 Digital – labeled D15 - D0
Pod 1: D7 - D0 Pod 2: D15 - D8 Threshold Selections TTL, CMOS, ECL, user-definable (selectable by pod) User-Defined Threshold Range ±8.0 V in 10 mV increments Maximum Input Voltage ±40 V peak CAT I Threshold Accuracy* ±(100 mV + 3% of threshold setting) Input Dynamic Range ±10 V about threshold Minimum Input Voltage Swing 500 mV peak-to-peak Input Capacitance ~ 8 pF Input Resistance 100 kΩ±2% at probe tip Channel-to-Channel Skew 2 ns typical, 3 ns maximum Horizontal Range 54621A/D, 54622A/D, 54624A: 5 ns/div to 50 s/div 54641A/D, 54642A/D: 1 ns/div to 50 s/div Resolution 54621A/D, 54622A/D, 54624A: 25 ps 54641A/D, 54642A/D: 2.5 ps Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on Reference Positions Left, Center, Right Delay Range 54621A/D, 54622A/D, 54624A: Pre-trigger (negative delay): Greater of 1 screen width or 10 ms Post-trigger (positive delay): 500 seconds 54641A/D, 54642A/D: Pre-trigger (negative delay): Greater of 1 screen width or 1 ms Post-trigger (positive delay): 500 seconds Analog Delta-t Accuracy 54621A/D, 54622A/D, 54624A: Same Channel*: ±0.01% reading ±0.1% screen width ±40 ps Channel-to-Channel: ±0.01% reading ±0.1% screen width ±80 ps 54641A/D, 54642A/D: Same Channel*: ±0.005% reading ±0.1% screen width ±20 ps Channel-to-Channel: ±0.005% reading ±0.1% screen width ±40 ps Same Channel Example (54641A/D, 54642A/D): for signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width), delta-t accuracy = ±{.005%(10 µs) + 0.1%(50 µs) + 20 ps} = 50.52 ns Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Horizontal (continued) Digital Delta-t Accuracy 54621A/D, 54622A/D, 54624A: (non-Vernier settings) Same Channel: ±0.01% reading ±0.1% screen width ±(1 digital sample period, 2.5 or 5 ns based on sample rate of 200/400 MSa/s) Channel-to-Channel: ±0.01% reading ±0.1% screen width ±(1 digital sample period, 2.5 or 5 ns) ±chan-to-chan skew (2 ns typical, 3 ns maximum) 54641A/D, 54642A/D: Same Channel: ±0.005% reading ±0.1% screen width ±(1 digital sample period, 1ns) Channel-to-Channel: ±0.005% reading ±0.1% screen width ±(1 digital sample period) ±chan-to-chan skew Same Channel Example (54641A/D, 54642A/D): for signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width), delta-t accuracy = ±{.005%(10 µs) + 0.1%(50 µs) + 1 ns} = 51.5 ns Delay Jitter <1 ppm RMS Jitter 0.025% screen width + 30 ps Modes Main, Delayed, Roll, XY XY Bandwidth: Max bandwidth Phase error @ 1 MHz: 1.8 degrees Z Blanking: 1.4 V blanks trace (use external trigger) - 54621A/D, 54622A/D, 54624A only Trigger System Sources: 54621A/622A, 54641A/642A: Ch 1, 2, line, ext 54621D/622D, 54641D/642D: Ch 1, 2, line, ext, D15 - D0 54624A: Ch 1, 2, 3, 4, line, ext Modes Auto, Triggered (normal), SingleAuto level (54621A/D, 54622A/D, 54624A only) Holdoff Time ~60 ns to 10 seconds Selections Edge, Pulse Width, Pattern, TV, Duration, Sequence, CAN, LIN, USB, I2C, SPI Edge Trigger on a rising or falling edge of any source Pattern Trigger on a pattern of high, low, and don’t care levels and/or a rising or falling edge established across any of the sources. The analog channel’s high or low level is defined by that channel’s trigger level. Pulse Width Trigger when a positive- or negative-going pulse is less than, greater than, or within a specified range on any of the source channels. Minimum pulse width setting: 5ns (2 ns on 54641A/D, 54642A/D analog channels) Maximum pulse width setting: 10 s TV Trigger on any analog channel for NTSC, PAL, PAL-M, or SECAM broadcast standards on either positive or negative composite video signals. Modes supported include Field 1, Field 2, or both, all lines, or any line within a field. Also supports triggering on non-interlaced fields. TV trigger sensitivity: 0.5 division of synch signal. Sequence Arm on event A, trigger on event B, with option to reset on event C or time delay. CAN Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. It can trigger on the Start of Frame bit of a data frame, a remote transfer request frame, or an overload frame. LIN Trigger on LIN (Local Interconnect Networking) sync break at beginning of message frame. USB Trigger on USB (Universal Serial Bus) Start of Packet, End of Packet, Reset Complete, Enter Suspend, or Exit Suspend on the differential USB data lines. USB low speed and full speed are supported. Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Trigger System (continued) I2C Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on Missing Acknowledge, Restart, EEPROM read, and 10 bit write. SPI Trigger on SPI (Serial Protocol Interface) data pattern during a specific framing period. Support positive and negative Chip Select framing as well as clock Idle framing and user specified number of bits per frame. Duration Trigger on a multi-channel pattern whose time duration is less than a value, greater than a value, greater than a time value with a timeout value, or inside or outside of a set of time values. Minimum duration setting: 5 ns Maximum duration setting: 10 s Autoscale Finds and displays all active analog and digital (for 54621D/54622D/54641D/54642D) channels, sets edge trigger mode on highest numbered channel, sets vertical sensitivity on analog channels and thresholds on digital channels, time base to display ~1.8 periods. Requires minimum voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50Hz. Analog Channel Triggering Range (internal) ±6 div from center screen Sensitivity* 54621A/D, 54622A/D, 54624A: Greater of 0.35 div or 2.5 mV 54641A/D, 54642A/D:<10mV/div: greater of 1 div or 5mV; ≥10mV/div: 0.6 div Coupling AC (~3.5 Hz on 54621A/D, 54622A/D, 54624A. ~10 Hz on 54641A/D, 54642A/D), DC, noise reject, HF reject and LF reject (~ 50 kHz) Digital (D15 - D0) Channel Triggering (54621D, 54622D, 54641D, and 54642D) Threshold Range (used defined) ±8.0 V in 10 mV increments Threshold Accuracy* ±(100 mV + 3% of threshold setting) Predefined Thresholds TTL = 1.4 V, CMOS = 2.5 V, ECL = -1.3 V External (EXT) Triggering Input Resistance 54621A/D, 54622A/D, 54624A: 1 MΩ, ±3% 54641A/D, 54642A/D: 1 MΩ±3% or 50 Ω Input Capacitance 54621A/D, 54622A/D, 54624A: ~ 14 pF 54641A/D, 54642A/D: ~13pF Maximum Input CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
5 Vrms with 50-ohm input
54621A/D, 54622A/D, 54624A: ±10 V 54641A/D, 54642A/D: DC coupling: trigger level ± 8V; AC coup./LFR: AC input minus trig level not to exceed ±8V Sensitivity 54621A/D, 54622A/D, 54624A: dc to 25 MHz, < 75 mV; 25 MHz to max bandwidth, < 150 mV 54641A/D, 54642A/D: dc to 100 MHz, < 100 mV; 100 MHz to max bandwidth, < 200 mV Coupling AC (~ 3.5 Hz), DC, noise reject, HF reject and LF reject (~ 50 kHz) Probe ID (Agilent/HP and Auto probe sense for 54621A/622A/641A/642A Tek compatible) Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Display System Display 7-inch raster monochrome CRT Throughput of Analog Channels 25 million vectors/sec per channel with 32 levels of intensity Resolution 255 vertical by 1000 horizontal points (waveform area) 32 levels of gray scale Controls Waveform intensity on front panel. Vectors on/off; infinite persistence on/off 8 x 10 grid with continuous intensity control Built-in Help System Key-specific help in 11 languages displayed by pressing and holding key or softkey of interest Real Time Clock Time and date (user setable) Measurement Features Automatic Measurements Measurements are continuously updated. Cursors track current measurement Voltage (analog channels only) Peak-to-Peak, Maximum, Minimum, Average, Amplitude, Top, Base, Overshoot, Preshoot, RMS (DC) Time Frequency, Period, + Width, - Width and Duty Cycle on any channels Rise time, Fall time, X at Max (Time at max volts), X at Min (Time at min volts), Delay, and Phase on analog channels only. Counter Built-in 5 digit frequency counter on any channel. Counts up to 125 MHz Threshold Definition Variable by percent and absolute value; 10%, 50%, 90% default for time measurements Cursors Manually or automatically placed readout of Horizontal (X, ∆X, 1/∆X) and Vertical (Y, ∆Y) Additionally digital or analog channels can be displayed as binary or hex values Waveform Math One function of 1-2, 1*2, FFT, differentiate, integrate. Source of FFT, differentiate, integrate: analog channels 1 or 2 (or 3 or 4 for 54624A), 1-2, 1+2, 1*2 FFT Points Fixed at 2048 points Source of FFT Analog channels 1 or 2 (or 3 or 4 on 54624A only), 1+2, 1-2, 1*2 Window Rectangular, Flattop, Hanning Noise Floor -70 to -100 dB depending on averaging Amplitude Display In dBV, dBm@50 Ω Frequency Resolution 0.097656/(time per div.) Maximum Frequency 102.4/(time per div.) Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Storage Save/Recall (non-volatile) 54621A/D, 54622A/D, 54624A: 3 setups and traces can be saved and recalled internally 54641A/D, 54642A/D: 4 setups and traces can be saved and recalled internally Floppy Disk 3.5” 1.44 MB double density Image formats : TIF, BMP Data formats: X and Y (time/voltage) values in CSV format Trace/setup formats: Recalled I/O RS-232 (Serial) Standard Port 1 port: XON or DTR; 8 data bits; 1 stop bit; parity = none; 9600, 19200, 38400, 57600 baud rates (use Agilent 34398A cable) Parallel Standard Port Printer support Printer Compatibility HP DeskJet, LaserJet with HP PCL 3 or greater compatibility: Black and white @150x150 dpi; Gray scale @ 600x600 dpi Epson: black and white @180x180 dpi Seiko thermal DPU-414: black and white Optional GPIB Interface Fully programmable with IEEE488.2 compliance Module (N2757A) Typical GPIB throughput of 20 measurements or twenty 2000-point records per second Optional Printer Kit The N2727A is a thermal printer kit, includingprinter power, parallel cable, power cable and paper General Characteristics Physical Size: 32.26 cm wide x 17.27 cm high x 31.75 cm deep (without handle) Weight: 6.35 kgs (14 lbs) on 54621A/D, 54622A/D, 54624A; 6.82 kgs (15 lbs) on 54641A/D, 54642A/D Probe Comp Output 54621A/D, 54642A/D, 54624A: Frequency ~1.2 kHz; Amplitude ~5 V 54641A/D, 54642A/D: Frequency ~2 kHz; Amplitude ~5 V Trigger Out 54621A/D, 54622A/D, 54624A: 0 to 5 V with 50 Ωsource impedance; delay ~ 55 ns 54641A/D, 54642A/D: 0 to 5 V with 50 Ωsource impedance; delay ~ 22 ns Printer Power 7.2 to 9.2 V, 1 A Kensington lock Connection on rear panel for security Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Performance Characteristics (continued) Power Requirements Line Voltage Range 54621A/D, 54622A/D, 54624A: 100 - 240 VAC ±10%, CAT II, automatic selection 54641A/D, 54642A/D: 100-240 VAC, 50/60 Hz, CAT II, automatic selection; 100-132 VAC, 440 Hz, CAT II, automatic selection Line Frequency 54621A/D, 54622A/D, 54624A: 47 to 440 Hz 54641A/D, 54642A/D: 50/60 Hz, 100-240 VAC; 440 Hz, 100-132 VAC Power Usage 54621A/D, 54622A/D, 54624A: 100 W max 54641A/D, 54642A/D: 110 W max Environmental Characteristics Ambient Temperature Operating -10 °C to +55 °C; Non-operating -51 °C to +71 °C Humidity Operating 95% RH at 40 °C for 24 hr; Non-operating 90% RH at 65 °C for 24 hr Altitude Operating to 4,570 m (15,000 ft); Non-operating to 15,244 m (50,000 ft) Vibration HP/Agilent class B1 and MIL-PRF-28800F; Class 3 random Shock HP/Agilent class B1 and MIL-PRF-28800F; (operating 30 g, 1/2 sine, 11-ms duration, 3 shocks/axis along major axis. Total of 18 shocks) Pollution Degree2 Normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation must be expected. Indoor Use Only This instrument is rated for indoor use only Other Installation Categories CAT I:Mains isolated CAT II:Line voltage in appliance and to wall outlet Regulatory Information: Safety IEC 61010-1:1990+A1:1992+A2:1995 / EN 61010-1:1994+A2:1995 UL 3111 CSA-C22.2 No. 1010.1:1992 Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly. The product was tested in a typical configuration with HP/Agilent test systems. Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
Ordering Information
2-channel 60 MHz Oscilloscope 54621D 2+16 channel 60 MHz Mixed Signal Oscilloscope 54622A 2-channel 100 MHz Oscilloscope 54622D 2+16 channel 100 MHz Mixed Signal Oscilloscope 54624A 4-channel 100 MHz Oscilloscope 54641A 2-channel 350 MHz Oscilloscope 54641D 2+16 channel 350 MHz Mixed Signal Oscilloscope 54642A 2-channel 500 MHz Oscilloscope 54642D 2+16 channel 500 MHz Mixed Signal Oscilloscope Accessories Included: 54621A 54621D 54622A 54622D 54624A 54641A 54641D 54642A 54642D User’s Guide (localized), √ Service Manual, Programmer’s Manual Power cord 10073C 10:1 divider probes with readout 10074C 10:1 divider probes with readout 16:2 x 8 input logic input probe assembly Accessories pouch and front panel cover IntuiLink software RS-232 cable ** IntuiLink Software available free on web at www.agilent.com/find/intuilink Manual Options (if no option is specified, English ABA will be shipped) ABA English ABJ Japanese AB2 Simplified Chinese
Shielding Option for use in severe environments or with sensitive devices under test – shields both ways (in and out): RS-03 Magnetic interface shielding added to CRT, and RE-02 display shield added to CRT to reduce radiated interference Option 1CM Rackmount kit (same as 1186A) Warranty and Calibration Options: All models include a standard 1-year warranty. Contact local sales office for prices of extended options: A6J ANSI/NSCL Z540 calibration with test data (replaces 1BP) R-50C-011-3 3-years of return-to-Agilent inclusive calibration service R-50C-013-3 3-years of return-to-Agilent inclusive plus calibration service R-50C-011-5 5-years of return-to-Agilent inclusive calibration service R-50C-013-5 5-years of return-to-Agilent inclusive plus calibration service R-51B-001-3C 1-year return-to-Agilent warranty, extended to 3-years R-51B-001-5C 1-year return-to-Agilent warranty, extended to 5-years Accessories Rackmount kit (same as option 1CM) N2726A Accessory pouch & front panel cover (standard with 100-MHz models, optional with 60-MHz models) N2727A Seiko thermal printer and pouch, parallel cable, power cable, 2 rolls paper, front panel cover N2728A 10 rolls of printer paper N2757A GPIB interface module for 54620-Series and 54640-Series scopes N2758A CAN trigger module Passive Probes 1:1 passive probe with ID 10073C 10:1 500 MHz passive probe with ID 10074C 10:1 150 MHz passive probe with ID Ordering Information (continued)
Ordering Information (continued) Fine Pitch Probing 0.5 mm, IC clip kit E2613B 0.5mm, Wedge probe adapter, 3-signal, qty 2 E2614A 0.5 mm, Wedge probe adapter, 8-signal, qty 1 E2643A 0.5 mm, Wedge probe adapter 16-signal, qty 1 E2615B 0.65mm, Wedge probe adapter, 3-signal, qty 2 E2616A 0.65 mm, Wedge probe adapter, 8-signal, qty 1 E2644A 0.65 mm, Wedge probe adapter, 16-signal, qty 1 Current Probes 100 kHz current probe, ac/dc N2774A 100:1, 4 kV 250 MHz probe with ID N2771A 1000:1, 15 kV, 50 MHz high voltage probe. Logic Probes 16:16 logic cable and terminator (for use with 54621D/622D/641D/642D) 54620-68701 16:2 x 8 logic input probe assembly (shipped standard with 54621D/622D/641D/642D) Active probes
800 MHz active probe
2-channel 750MHz active probe 1142A power supply for 1144A and 1145A Differential Probes Differential probe power supply Cables GPIB cable, 1m long 34398A RS-232 cable (standard with 100 MHz, 350 MHz, and 500 MHz scopes) Call the measurement experts at Agilent Technologies Whether your work is mostly digital, mostly analog, or somewhere in the middle, our measurement specialists can help you select the best debugging solution. Call today to talk to a knowledgeable engineer about your particular application. See for yourself with a no-obligation, 2- week demo If you'd like to see for yourself how an Agilent 54600-Series scope can help you solve your mixed analog and digital design problems, just give us a call. We'll arrange for you to use a 54620-Series scope in your lab for two weeks with no obligation to buy. Call 1-800-452-4844 and ask for Direct Demo or visit our website: www.agilent.com/find/MSO. Money-back guarantee Get a full refund if you’re not satisfied with your purchase for any reason within 60 days in the USA or 90 days outside of the USA.
Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. www.agilent.com MICROSOFT and VISUAL STUDIO .NET are registered trademarks of Microsoft Corporation in the U.S. and/or other countries. www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent T&M Software and Connectivity Agilent's Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 67556 0042 Email: tm_ap@agilent.com Contacts revised: 9/17/04 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2004 Printed in USA November 16, 2004 5968-8152EN www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Direct