5300 MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
KMP_5300C_C01 Page 1 of 3
5300 Series
10A Current Sensing Transformers www.murata-ps.com For full details go to www.murata-ps.com/rohs www.murata.com For full details go to www.murata-ps.com/rohs
FEATURES
RoHS compliant Primary current rating 10A 20 to 200 turn variants Primary to secondary isolation 500Vrms 50kHz-500kHz frequency range Surface mount Industry-standard footprint UL94 V-0 package materials J-STD-020C reflow PRODUCT OVERVIEW The 5300 series of current sense transformers are designed to monitor AC currents. The transformers can be used for high frequency current sensing in applications such as switched-mode power supplies, motor control, and electronic lighting ballasts. SELECTION GUIDE Order Code Turns Ratio Min. Secondary Inductance Max. DC Resistance Isolation Voltage1 Terminating Resistance to produce 1VOUT/1AIN Primary (8-7) Secondary (1-3) mH mΩ Ω V rms Ω 53020C 1:20 0.08 7.0 0.55 500 20 53030C 1:30 0.18 7.0 0.85 500 30 53040C 1:40 0.32 7.0 1.10 500 40 53050C 1:50 0.50 7.0 1.75 500 50 53060C 1:60 0.72 7.0 2.20 500 60 53070C 1:70 0.98 7.0 4.50 500 70 53100C 1:100 2.00 7.0 5.60 500 100 53125C 1:125 3.00 7.0 7.50 500 125 53150C 1:150 4.50 7.0 17.50 500 150 53200C 1:200 8.00 7.0 34.00 500 200 ABSOLUTE MAXIMUM RATINGS Operating free air temperature range -40°C to 125°C Storage temperature range -40°C to 155°C SOLDERING INFORMATION2 Peak reflow solder temperature 250˚C Pin finish Tin Moisture sensitivity level 1 PACKAGE SPECIFICATIONS Mechanical Dimensions Weight = 0.34g Typ. Unless otherwise stated, all dimensions in mm (inches) ±0.25 (0.010). * True dimension before tin dipping. Recommended Footprint Details Schematic Unless otherwise stated, all dimensions in mm (inches) ±0.25 (0.010). Specifications typical at TA = 25°C 1 Flash tested for 1 second. 2 For further information, please visit www.murata-ps.com/rohs 150 5.4 (0.213) Max. 7.2 (0.283) Max. 8.3 (0.327) Max. 0.2±0.1 (0.008±0.004) 0.5±0.1 (0.020±0.004) 1.85±0.15 (0.073±0.006) 0.2±0.1* (0.008±0.004) 654 123 3.05 (0.120) 1.85 (0.073) 2.54 (0.1) 2.69 (0.106) 1.27 (0.050) 5.59 (0.220) 1.52 (0.060) Primary Secondary
KMP_5300C_C01 Page 2 of 3 10A Current Sensing Transformers www.murata.com PACKAGE SPECIFICATIONS Reel Dimensions Tape Outline Dimensions 150 150 150 150 Direction of unreeling 7.5 (0.295) 12.0 (0.472) 16.0 (0.630) 5.8 (0.228) Reel quantity: 1,000 All dimensions in mm (inches) 22.4 (0.882) Max.† 15.9-19.4* (0.626-0.764) 16.3-16.7 (0.642-0.657) 13.50 12.50 0.531 0.492ØØ 1.50 (0.059) Min. 49.75 (1.96) Min. Ø21.1 (Ø0.83) Min. 100 (3.937) Min. Leader Section 400 (15.748) Min. Goods Enclosure Section Trailer Section 160 (6.299) Min. Ø331 (13.031) Max. All dimensions in mm (inches) * Includes flange distortion at outer edge † Measured at hub
KMP_5300C_C01 Page 3 of 3 10A Current Sensing Transformers www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2021 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment ( automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.