5150_17 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Power Entry Modules with Line Filter 5150https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 with High Frequency Filter, X2Y Technology, ECO design, Front- or Rear Side Mounting Screw or rivet fastening from front or rear side Screw-on mounting from rear side (integrated thread) Approvals and Compliances C14 70° C
Description
- Panel Mount : Screw-on version from front or rear side - 2 Functions : Appliance Inlet , High frequency line filter as standard, industrial and medical version , Protection class I - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Filter for highest frequencies - X2Y® Technology - Double shielding for best filter performance - Metal flange for optimal shielding Characteristics - Very compact filter for frequencies up to 1 GHz Patented X2Y Technologie for broadband high frequency filtering - Double shielding for best filter performance One single filter design for the given current range - Designed for standard, industrial and medical applications Suitable for assembly in metal plated plastic housings - Suitable for use in equipment according to IEC 60950/60601 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Solder terminals - Variant with notch for V-Lock mating Cordsets Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 15 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 43/80 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Themoplast / steel tin-plated, black / metallic, UL 94V-0 appliance inlet/-outlet C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Line Filter Standard, medical and industrial ver- sion, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 3'300'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals
Power Entry Modules with Line Filter5150 https://www.schurter.com /PG06 EMC Products Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 5150 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40023426 UL Approvals UL UL File Number: E72928 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
Power Entry Modules with Line Filter 5150https://www.schurter.com /PG06 EMC Products Dimension [mm] Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting) 12 31 239.540 48.6 54.5 24.6 4.4 8.5 3.6 29±0.1 21.5 max.R3 ±0.1 ±0.10 Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting) 12 31 239.540 48.6 54.5 24.6 4.4 30.5±0.1 22.5 max.R3 ±0.1 ±0.10 3.6 8.5 Technical Data of Filter-Components Rated Current [A] Filter-Type Capacitance CY [nF] R [MΩ] 10 Standard Version 2.5 - 10 Standard Version with Bleed Resistor 2.5 1 10 Industrial Version 4.7 - 10 Medical Version (M80) 0.45 1
Power Entry Modules with Line Filter5150 https://www.schurter.com /PG06 EMC Products Diagrams Standard and industrial version 1) 2) 1) Line 2) Load Medical M80 and standard version with bleed resistor 1) 2) 1) Line 2) Load Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version CISPR 17 Test Method same attenuation loss with bleed resistor Alternate Test Method Medical version (M80) CISPR 17 Test Method Alternate Test Method Industrial version CISPR 17 Test Method Alternate Test Method Comment about alternate test method see table of variants All Variants Rated Current IEC [A] Rated Current UL [A] Filter-Type Panel mounting Mounting side Order Number 10 15 Standard Version Screw-on/Rivet Front-/Rear-Side 5150.0011.0 10 15 Standard Version Screw Rear Side 5150.0011.1 10 15 Standard Version with Bleed Resistor Screw-on/Rivet Front-/Rear-Side 5150.0021.0 10 15 Standard Version with Bleed Resistor Screw Rear Side 5150.0021.1 10 15 Industrial Version Screw-on/Rivet Front-/Rear-Side 5150.0041.0 10 15 Industrial Version Screw Rear Side 5150.0041.1 10 15 Medical Version (M80) Screw-on/Rivet Front-/Rear-Side 5150.0031.0 10 15 Medical Version (M80) Screw Rear Side 5150.0031.1
Power Entry Modules with Line Filter 5150https://www.schurter.com /PG06 EMC Products Rated Current IEC [A] Rated Current UL [A] Filter-Type Panel mounting Mounting side Order Number Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER The Alternate Test Method allows the measurement in the GHz frequency range whereas the CISPR 17 method does not cover frequencies above 30MHz. The insertion loss is measured in a throughput method (common mode) and a cross coupled method (differential mode). The differential mode measurement of the alternate test method is not directly comparable to the conventional measurement acc. CISPR 17. Further information on the X2Y filter technology and on the alternate insertion loss measurement method can be found under www. schurter.com/info_emc Packaging unit 10 Pcs Accessories 0859.0048 Cord retaining kits Cord retaining strain relief Flat head, E 4700.0005 Flat head, G 4700.0007 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 5150 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to 5150 ...
Power Entry Modules with Line Filter5150 https://www.schurter.com /PG06 EMC Products Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to 5150 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 02.12.2017