Power Entry Modules with Line Filter 5145https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45 Protection class I with shield Protection class II without shield Approvals and Compliances C14 70° C C18 70° C

Description

  • Panel Mount : Screw-on mounting from front side - 3 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Compact power entry module with circuit breaker - High configurability - Easy assembly with prewired modules - Protection class I or II Characteristics - All single elements are already wired - Unwired versions available on request - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 References Alternative: version without line filter 6145 We recommend for new applications the new type DF12 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -10 °C to 55 °C Climatic Category 10/055/21 acc. to IEC 60068-1 IP-Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I or II acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 or C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Line Filter Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 100'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 5145 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40035745 UL Approvals UL UL File Number: E72928

Power Entry Modules with Line Filter5145 https://www.schurter.com /PG06 EMC Products Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Power Entry Modules with Line Filter 5145https://www.schurter.com /PG06 EMC Products Dimension [mm] 3.25 +0.1 ±0.1 M3/ø 3.6 ø 6 Detail A 50.7 67.5* 13.5 6.3x0.8mm 6.3x0.8mm 91.5 R 3 -0.5 +0.2 A * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2 x 4 47 2.2 - 3 Standard Version 2 x 2.5 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 15 Standard Version 2 x 0.1 47 2.2 -

1 Medical Version (M5) 2 x 11 47 - 1

2 Medical Version (M5) 2 x 4 47 - 1

6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 15 Medical Version (M5) 2 x 0.1 47 - 1

Power Entry Modules with Line Filter5145 https://www.schurter.com /PG06 EMC Products Diagrams Standard version Cx Cy Cy PE’ L PE N TA 45 1) Line 2) Load Medical version (M5) Cx R PE’ L PE N TA 45 1) Line 2) Load Medical filter (M5) protection class II Cx R L N TA 45 1) Line 2) Load Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1 A 2 A 3 A 4 A 6 A 8 A 10 A 15A

Power Entry Modules with Line Filter 5145https://www.schurter.com /PG06 EMC Products Medical version (M5) 1 A 2 A 3 A 4 A 6 A 8 A 10 A 15A

Power Entry Modules with Line Filter5145 https://www.schurter.com /PG06 EMC Products ABT W F 150 C0 Colours Switch front Rocker W black white – B black black – 6 black – orange transp. F embossed / Relief H printed / bedruckt white / weiss K printed / bedruckt black / schwarz L printed / bedruckt white / weiss Surface Illustration Colour of print Rocker legend l O ON OFF ON OFF l O M printed black P printed white R printed black Surface Illustration Colour of print Rated current circuit breaker of equipment Without release: code C0 Undervoltage release Remote trip release UE ZA Code Rated voltage Un

  • • •
  • • •
  • • •

240 V AC

230 V AC

120 V AC

l O OI OI Position of the r ocker legend e.g F In Code 0,1 J01 0,2 J02 0,3 J03 0,4 J04 0,5 J05 0,6 J06 0,7 J07 0,8 J08 0,9 J09 1,0 J10 1,1 J11 1,2 J12 In Code 1,3 J13 1,4 J14 1,5 J15 1,6 J16 1,7 J17 1,8 J18 1,9 J19 2,0 J20 2,1 J21 2,2 J22 2,3 J23 2,5 J25 In Code 2,8 J28 3,0 030 3,5 035 4,0 040 4,5 045 5,0 050 6,0 060 6,5 065 7,0 070 7,5 075 8,0 080 9,0 090 In Code 10,0 100 11,0 110 12,0 120 13,0 130 14,0 140 15,0 150 20,0 200 Table 1 Selection for type T A45 Order example

  • Circuit Breaker of Equipment
  • 2-pole, rocker actuated
  • Quick connect terminal Other types on r equest Without illumination With illumination 220…240 V 110…120 V Diagram Thermal overload pr otection 1-pole 2-pole ABT ABD A12 A32 A14 A34 P2 P1 P2 P1 P2 P1 P2 P1b P2 P1b a P2 P1c

Power Entry Modules with Line Filter 5145https://www.schurter.com /PG06 EMC Products Technical data (continued) Circuit breaker Effect of ambient temperatur e 1) The unit is calibrated for an ambient temperatur e of +23 °C. To deter mine the rated curr ent for a lower or higher ambient tempera- ture, use a correction factor fr om the table below. * Ambient temperatur e [°C] Correction factor –10 0,89 – 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 Configuration code (example) 1) Example Rated current at +23 °C 6,0 A Ambient temperatur e +40 °C Correction factor 1,08 Chosen rated curr ent at + 40 °C ambient temperatur e 6 A x 1,08 = 6,5 A * Temperature must be measur ed at the rear of the breaker next to the terminals after equipment operating temperatur e has been reached. Type Tripping characteristics In < 3 A Tripping characteristics 10’000 2000 1000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 Multiple of rated current [ x In ] 10854321,32 Tripping time Type TA45 Rated current In < 3 A 1-pole protected 2-pole protected Ambient temp. +23 °C 10’000 2’000 1’000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 [ x In ] 10854321,32 Type TA45 Rated current I > 3... < 15 A 1-pole protected 2-pole protected Ambient temp. +23 °C Multiple of rated current Tripping time n Optional Variants 00 standard

21 V-Lock notch

0 without (PCII) 1 QC 6.3x0.8 Terminal L and N 1 QC 6.3x0.8, without connection to TA45

3 Connection to TA45 non insulated

0 with metal shield (PCI) 1 without metal shield (PCI and PCII) Type of mains fi lter / capacitor / bleed resistor 1 standard X2,Y2 without 1) 3 medical M5 X2 with Rated current 2) 1 1A 2 2A 3 3A 4 4A 5 6A 6 8A 7 10A 8 15A1) Not in conjunction with PC II 2) The rated current of the line-fi lter must be equal or more than the rated current of TA45. see table 1 5145 - ABTWF150C0 - 000 - 111 - 10 - 00 Order code TA45 (2-pole rocker-switch without accessories)

Power Entry Modules with Line Filter5145 https://www.schurter.com /PG06 EMC Products Packaging unit 20 Pcs Accessories 0859.0074 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 5145 Connector Overview complete

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to 5145 ... Mating Outlets/Connectors shuttered Power Cord Overview complete Power cord with IEC connector C17, V-Lock, straight VAC17KS Power Cord further types to 5145 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 02.12.2017