5120_18 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 11
Technical content
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 or C18 with Filter, ECO design, Front- or Rear Side Mounting Front side mounting with plastic flange Snap-in mounting Quick connect terminals 6.3 x 0.8 mm Protection class II Screw-on mounting with wires (stranded) Approvals and Compliances C14 70° C C18 70° C
Description
- Panel Mount : Screw-on version from front or rear side, snap-in version from front side, PCB Version from rear side - 2 Functions : Appliance Inlet protection class I or II , Line filter in standard and medi- cal version - Solder, quick connect or wire (stranded) - PCB Mounting - Earth Terminal Unique Selling Proposition - Various variants - Metal flange for optimal shielding - Compact design - Variants for protection class I and II Characteristics - Compact high performance filter Optimal shielding due to completely closed filter case, unpotted - Suitable for assembly in metal plated plastic housings - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Snap-in for panel thickness >2mm to 3mm - flexible wire with various lenghts - Class X1- and Y1-capacitors for enhanced withstand voltage - Medical version M80 - Variant with notch for V-Lock mating Cordsets References Alternative: version without line filter 6100-3; 6100-4; 6102-3; 6102-5 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I or II acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Solder terminals Flexible wire AWG18 (15A AWG16), 150 mm Panel Thickness S Screw with plastic flange: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 2 mm (all steps with one variant) Material: Housing Themoplast / steel tin-plated, black / metallic, UL 94V-0 appliance inlet/-outlet C14 / C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Line Filter Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 3'000'000 h acc. to MIL-HB-217 F Approvals and Compliances
Power Entry Modules with Line Filter5120 https://www.schurter.com /PG06 EMC Products Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 5120 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40016382 UL Approvals UL UL File Number: E72928 CQC Approvals CQC CCC File Number: CQC17001171087 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products Dimensions [mm] Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting) 12 2.9 1239.540 48.6 54.9 24.6 4.4 8.5 3.6 29±0.1 21.5 max.R3 ±0.1 ±0.10 Front side mounting with plastic flange 12 2.9 1239.540 48.6 54.9 24.6 4.4 8.5 3.5 29±0.1 21.5 max.R3 ±0.1 ±0.10 Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting) 12 2.9 1239.540 48.6 24.6 4.4 30.5±0.1 22.5 max.R3 ±0.1 ±0.10 3.6 Dimensions for class II version also apply to class I
Power Entry Modules with Line Filter5120 https://www.schurter.com /PG06 EMC Products Snap-in mounting from front side 12 2.9 1239.532.6 54.9 24.6 4.4 8.5 29.4 21.5 max.R1.5 ±0.10 ±0.10 Dimensions for class I version also apply class II PCB snap-in rear side mounting, protection class II 2.9 1239.540 48.6 49.2 M3 26.2 2715.5 30.5 22.5 max.R3 ±0.10 ø3.6 ±0.10 ±0.10 27±0.10 12±0.10 ø1.6 +0.100 ±0.05 4.6
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products PCB rear side mounting, protection class II 2.9 1239.540 48.6 M3 30.8 2715.5 30.5 22.5 max.R3 ±0.10 ø3.6 ±0.10 ±0.10 12±0.10 30.8±0.10 ø1.6 +0.100 Screw and snap-in mounting with flexible wire 2.9 1339.5 54.948.6 24.6 150 46.1 30.5 22.5 max.R3 max.R1.5 ±0.10 29.4±0.10 ø3.6 ±0.10 21.5±0.10 ±0.10 8.5 1.25 21.5 max.R3 ±0.10 ±0.10 ±0.10 1) 2) 4)3) 5) 1) Flexible wire, standard length 150 mm or special length on request 2) Nonexistent for protection class II 3) Panel cut-out screw-on version, back-side mounting 4) Panel cut-out screw-on version, front- or back-side mounting 5) Panel cut-out snap-in version, front-side mounting
Power Entry Modules with Line Filter5120 https://www.schurter.com /PG06 EMC Products Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 12 100 2.2 - 2 Standard Version 2 x 5.2 100 2.2 - 4 Standard Version 2 x 2 100 2.2 - 6 Standard Version 2 x 0.8 100 2.2 - 10 Standard Version 2 x 0.4 100 2.2 - 15 Standard Version 2 x 0.1 100 2.2 -
1 Medical Version (M5) 2 x 12 100 - 1
2 Medical Version (M5) 2 x 5.2 100 - 1
4 Medical Version (M5) 2 x 2 100 - 1
6 Medical Version (M5) 2 x 0.8 100 - 1 10 Medical Version (M5) 2 x 0.4 100 - 1 15 Medical Version (M5) 2 x 0.1 100 - 1 1 Bleed Resistor Version 2 x 12 100 2.2 1 2 Bleed Resistor Version 2 x 5.2 100 2.2 1 4 Bleed Resistor Version 2 x 2 100 2.2 1 6 Bleed Resistor Version 2 x 0.8 100 2.2 1 10 Bleed Resistor Version 2 x 0.4 100 2.2 1 15 Bleed Resistor Version 2 x 0.1 100 2.2 1 Diagrams Standard version 1) 2) L N PE PE’ R Cx Cy Cy 1) Line 2) Load Bleed resistor version / medical version M80 1) 2) L N PE PE’ R Cx Cy Cy 1) Line 2) Load Medical version M5 1) 2) L N PE PE’ R Cx 1) Line 2) Load Medical version M5, prot. class II 1) 2) L N R Cx 1) Line 2) Load
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1 A 2 A 4 A 6 A 10 A 15 A Medical version (M5) 1 A 2 A 4 A 6 A 10 A 15 A All Variants Rated Cur- rent [A] Filter-Type Mounting Mounting side Terminal Protection Class V-Lock Order Number 6 Standard Version Snap-in 2 - 3 mm Front Side Flexible wire I 5120.3034.0 1 Standard Version Snap-in Front Side Quick connect I 5120.2000.0 2 Standard Version Snap-in Front Side Quick connect I 5120.2001.0 █ 4 Standard Version Snap-in Front Side Quick connect I 5120.2003.0 █ 6 Standard Version Snap-in Front Side Quick connect I 5120.2004.0 10 Standard Version Snap-in Front Side Quick connect I 5120.2006.0 10 Standard Version Snap-in Front Side Flexible wire and I 5120.2046.0 15 Standard Version Snap-in Front Side Quick connect I 5120.2007.0 █ 1 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I l 5120.5070.0 2 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5071.0 4 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5073.0 6 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5074.0 10 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5076.0 15 Standard Version Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5077.0
Power Entry Modules with Line Filter5120 https://www.schurter.com /PG06 EMC Products Rated Cur- rent [A] Filter-Type Mounting Mounting side Terminal Protection Class V-Lock Order Number 1 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4070.0 2 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4071.0 4 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4073.0 6 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4074.0 10 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4076.0 15 Standard Version Screw/PCB Rear Side PCB pin and earth I 5120.4077.0 1 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0000.0 1 Standard Version Screw-on/Rivet Front-/Rear-Side Solder terminals I 5120.0010.0 2 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0001.0 █ 4 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0003.0 █ 6 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0004.0 █ 10 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0006.0 █ 15 Standard Version Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0007.0 █ 15 Standard Version Screw-on/Rivet Front-/Rear-Side Flexible wire I 5120.0057.0
1 Standard Version Screw with plastic flange Front Side Quick connect I l 3-101-140
2 Standard Version Screw with plastic flange Front Side Quick connect I l 3-101-141 █
4 Standard Version Screw with plastic flange Front Side Quick connect I l 3-101-142 █
6 Standard Version Screw with plastic flange Front Side Quick connect I l 3-101-143 █
10 Standard Version Screw with plastic flange Front Side Quick connect I l 3-100-776 █
15 Standard Version Screw with plastic flange Front Side Quick connect I l 3-101-144 █
1 Standard Version Screw Rear Side Quick connect I 5120.1000.0 2 Standard Version Screw Rear Side Quick connect I 5120.1001.0 4 Standard Version Screw Rear Side Quick connect I 5120.1003.0 █ 6 Standard Version Screw Rear Side Quick connect I 5120.1004.0 █ 10 Standard Version Screw Rear Side Quick connect I 5120.1006.0 █ 10 Standard Version Screw Rear Side Quick connect I l 5120.1006.0.21 10 Standard Version Screw Rear Side Flexible wire and I 5120.1046.0 15 Standard Version Screw Rear Side Quick connect I 5120.1007.0 15 Standard Version Screw Rear Side Quick connect I l 5120.1007.0.21 1 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2300.0 2 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2301.0 4 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2303.0 6 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2304.0 10 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2306.0 █ 15 Medical Version (M5) Snap-in Front Side Quick connect I 5120.2307.0 4 Medical Version (M5) Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5373.0 6 Medical Version (M5) Screw/PCB snap-in Rear Side PCB pin and earth I 5120.5374.0 4 Medical Version (M5) Screw/PCB Rear Side PCB pin and earth I 5120.4373.0 6 Medical Version (M5) Screw/PCB Rear Side PCB pin and earth I 5120.4374.0 1 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0300.0 2 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0301.0 4 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0303.0 █ 4 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Flexible wire and I 5120.0343.0 6 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0304.0 10 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0306.0 15 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect I 5120.0307.0
1 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-101-145
2 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-101-146
4 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-100-794 █
6 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-101-147
10 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-101-148
15 Medical Version (M5) Screw with plastic flange Front Side Quick connect I l 3-101-149
1 Medical Version (M5) Screw Rear Side Quick connect I 5120.1300.0 2 Medical Version (M5) Screw Rear Side Quick connect I 5120.1301.0
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products Rated Cur- rent [A] Filter-Type Mounting Mounting side Terminal Protection Class V-Lock Order Number 4 Medical Version (M5) Screw Rear Side Quick connect I 5120.1303.0 6 Medical Version (M5) Screw Rear Side Quick connect I 5120.1304.0 10 Medical Version (M5) Screw Rear Side Quick connect I 5120.1306.0 10 Medical Version (M5) Screw Rear Side Quick connect I l 5120.1306.0.21 10 Medical Version (M5) Screw Rear Side Flexible wire and I 5120.1346.0 15 Medical Version (M5) Screw Rear Side Quick connect I 5120.1307.0 1 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2300.1 2 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2301.1 4 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2303.1 6 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2304.1 10 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2306.1 15 Medical Version (M5) Snap-in Front Side Quick connect II 5120.2307.1 4 Medical Version (M5) Screw/PCB snap-in Rear Side PCB pin and earth II 5120.5373.1 6 Medical Version (M5) Screw/PCB snap-in Rear Side PCB pin and earth II 5120.5374.1 10 Medical Version (M5) Screw/PCB snap-in Rear Side PCB pin and earth II 5120.5376.1 4 Medical Version (M5) Screw/PCB Rear Side PCB pin and earth II 5120.4373.1 6 Medical Version (M5) Screw/PCB Rear Side PCB pin and earth II 5120.4374.1 2 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect II 5120.0301.1 4 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect II 5120.0303.1 6 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Quick connect II 5120.0304.1 10 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side Solder terminals II 5120.0316.1 1 Medical Version (M5) Screw Rear Side Quick connect II 5120.1300.1 2 Medical Version (M5) Screw Rear Side Quick connect II 5120.1301.1 2 Medical Version (M5) Screw Rear Side Solder terminals II 5120.1311.1 4 Medical Version (M5) Screw Rear Side Quick connect II 5120.1303.1 6 Medical Version (M5) Screw Rear Side Quick connect II 5120.1304.1 10 Medical Version (M5) Screw Rear Side Quick connect II 5120.1306.1 2 Bleed Resistor Version Snap-in Front Side Quick connect I 5120.2201.0 4 Bleed Resistor Version Snap-in Front Side Quick connect I 5120.2203.0 6 Bleed Resistor Version Snap-in Front Side Quick connect I 5120.2204.0 10 Bleed Resistor Version Snap-in Front Side Quick connect I 5120.2206.0 15 Bleed Resistor Version Snap-in Front Side Quick connect I 5120.2207.0 15 Bleed Resistor Version Snap-in Front Side Quick connect I l 5120.2207.0.21 10 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side Solder terminals I 5120.0216.0 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER - 15 A version only according UL/CSA - Type for screw-on mounting from rear side has pre-threaded holes for M3 screws Variants with plastic flange are all V-Lock versions. Packaging unit 10 Pcs
Power Entry Modules with Line Filter5120 https://www.schurter.com /PG06 EMC Products Accessories Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0048 Cord retaining kits Cord retaining strain relief Flat head, E 4700.0005 Flat head, G 4700.0007 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 5120 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to 5120 ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power cord with IEC connector C17, V-Lock, straight VAC17KS Power Cord further types to 5120
Power Entry Modules with Line Filter 5120https://www.schurter.com /PG06 EMC Products The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 09.01.2018