Technical content

Power Entry Modules with Line Filter 520 www.schurter.com/pg06 EMC Products IEC Appliance Inlet C14 or C18 with Filter, ECO design, Front- or Rear Side Mounting Snap-in mounting from front side Protection class II Standard- or Medical-Filter C14 70° C

Description

  • Panel Mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Appliance Inlet, protection class I or II, Line filter in standard and medi- cal version Quick connect terminals 6.3 x 0.8 mm Approvals - VDE License Number: 40016382 - UL License Number: E72928 Characteristics - Compact high performance filter Optimal shielding due to completely closed filter case, unpotted - Designed for standard and medical applications Suitable for assembly in metal plated plastic housings - Qualified for use in equipment according IEC/EN 60950 Other versions on request - Snap-in for panel thickness >2mm to 3mm - Solder terminals - Class X1 capacitor for enhanced surge withstand voltage - Medical version M80 References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories T echnical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 or 2 acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness s Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 2 mm (all steps with one variant) Material: Housing Themoplast / steel tin-plated, black / metallic, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 or 2 Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 3'000'000 h acc. to MIL-HB-217 F

Power Entry Modules with Line Filter520 www.schurter.com/pg06 EMC Products Dimensions 54.5 mm Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting) 12 3 1239.540 48.6 54.5 24.6 4.4 8.5 3.6 29±0.1 21.5 max.R3 ±0.1 ±0.10 Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting) 12 3 1239.540 48.6 54.5 24.6 4.4 30.5±0.1 22.5 max.R3 ±0.1 ±0.10 3.6 Dimensions for class II version also apply to class I Snap-in mounting from front side 12 3 1239.532.6 54.5 24.6 4.4 8.5 29.4 21.5 max.R1.5 ±0.10 ±0.10 Dimensions for class I version also apply class II

Power Entry Modules with Line Filter 520 www.schurter.com/pg06 EMC Products T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 12 100 2.2 - 2 Standard Version 2 x 5.2 100 2.2 - 4 Standard Version 2 x 2 100 2.2 - 6 Standard Version 2 x 0.8 100 2.2 - 10 Standard Version 2 x 0.4 100 2.2 - 15 Standard Version 2 x 0.1 100 2.2 -

1 Medical Version (M5) 2 x 12 100 - 1

2 Medical Version (M5) 2 x 5.2 100 - 1

4 Medical Version (M5) 2 x 2 100 - 1

6 Medical Version (M5) 2 x 0.8 100 - 1 10 Medical Version (M5) 2 x 0.4 100 - 1 15 Medical Version (M5) 2 x 0.1 100 - 1 1 Bleed Resistor Version 2 x 12 100 2.2 1 2 Bleed Resistor Version 2 x 5.2 100 2.2 1 4 Bleed Resistor Version 2 x 2 100 2.2 1 6 Bleed Resistor Version 2 x 0.8 100 2.2 1 10 Bleed Resistor Version 2 x 0.4 100 2.2 1 15 Bleed Resistor Version 2 x 0.1 100 2.2 1 Diagrams Standard version 1) Line 2) Load Bleed resistor version 1) Line 2) Load Medical version M5 1) Line 2) Load Medical version M5, prot. class II 1) Line 2) Load Attenuation Loss - - - - differential mode _____ common mode Standard version 1 A 2 A 4 A 6 A 10 A 15 A

Power Entry Modules with Line Filter520 www.schurter.com/pg06 EMC Products Medical version (M5) 1 A 2 A 4 A 6 A 10 A 15 A Variants Rated Cur- rent [A] Filter-Type Panel mounting Mounting side Protection Class Order Number 1 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0000.0 2 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0001.0 4 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0003.0 6 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0004.0 10 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0006.0 15 Standard Version Screw-on/Rivet Front-/Rear-Side 1 5120.0007.0 1 Standard Version Screw Rear-Side 1 5120.1000.0 2 Standard Version Screw Rear-Side 1 5120.1001.0 4 Standard Version Screw Rear-Side 1 5120.1003.0 6 Standard Version Screw Rear-Side 1 5120.1004.0 10 Standard Version Screw Rear-Side 1 5120.1006.0 15 Standard Version Screw Rear-Side 1 5120.1007.0 1 Standard Version Snap-in Front-Side 1 5120.2000.0 2 Standard Version Snap-in Front-Side 1 5120.2001.0 4 Standard Version Snap-in Front-Side 1 5120.2003.0 6 Standard Version Snap-in Front-Side 1 5120.2004.0 10 Standard Version Snap-in Front-Side 1 5120.2006.0 15 Standard Version Snap-in Front-Side 1 5120.2007.0 1 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0300.0 2 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0301.0 4 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0303.0 6 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0304.0 10 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0306.0 15 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 1 5120.0307.0 1 Medical Version (M5) Screw Rear-Side 1 5120.1300.0 2 Medical Version (M5) Screw Rear-Side 1 5120.1301.0 4 Medical Version (M5) Screw Rear-Side 1 5120.1303.0 6 Medical Version (M5) Screw Rear-Side 1 5120.1304.0 10 Medical Version (M5) Screw Rear-Side 1 5120.1306.0 15 Medical Version (M5) Screw Rear-Side 1 5120.1307.0 1 Medical Version (M5) Snap-in Front-Side 1 5120.2300.0 2 Medical Version (M5) Snap-in Front-Side 1 5120.2301.0 4 Medical Version (M5) Snap-in Front-Side 1 5120.2303.0 6 Medical Version (M5) Snap-in Front-Side 1 5120.2304.0 10 Medical Version (M5) Snap-in Front-Side 1 5120.2306.0 15 Medical Version (M5) Snap-in Front-Side 1 5120.2307.0

Power Entry Modules with Line Filter 520 www.schurter.com/pg06 EMC Products Rated Cur- rent [A] Filter-Type Panel mounting Mounting side Protection Class Order Number 2 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 2 5120.0301.1 4 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 2 5120.0303.1 6 Medical Version (M5) Screw-on/Rivet Front-/Rear-Side 2 5120.0304.1 1 Medical Version (M5) Screw Rear-Side 2 5120.1300.1 2 Medical Version (M5) Screw Rear-Side 2 5120.1301.1 4 Medical Version (M5) Screw Rear-Side 2 5120.1303.1 6 Medical Version (M5) Screw Rear-Side 2 5120.1304.1 10 Medical Version (M5) Screw Rear-Side 2 5120.1306.1 1 Medical Version (M5) Snap-in Front-Side 2 5120.2300.1 2 Medical Version (M5) Snap-in Front-Side 2 5120.2301.1 4 Medical Version (M5) Snap-in Front-Side 2 5120.2303.1 6 Medical Version (M5) Snap-in Front-Side 2 5120.2304.1 10 Medical Version (M5) Snap-in Front-Side 2 5120.2306.1 15 Medical Version (M5) Snap-in Front-Side 2 5120.2307.1 1 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0200.0 2 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0201.0 4 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0203.0 6 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0204.0 10 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0206.0 15 Bleed Resistor Version Screw-on/Rivet Front-/Rear-Side 1 5120.0207.0 1 Bleed Resistor Version Screw Rear-Side 1 5120.1200.0 2 Bleed Resistor Version Screw Rear-Side 1 5120.1201.0 4 Bleed Resistor Version Screw Rear-Side 1 5120.1203.0 6 Bleed Resistor Version Screw Rear-Side 1 5120.1204.0 10 Bleed Resistor Version Screw Rear-Side 1 5120.1206.0 15 Bleed Resistor Version Screw Rear-Side 1 5120.1207.0 1 Bleed Resistor Version Snap-in Front-Side 1 5120.2200.0 2 Bleed Resistor Version Snap-in Front-Side 1 5120.2201.0 4 Bleed Resistor Version Snap-in Front-Side 1 5120.2203.0 6 Bleed Resistor Version Snap-in Front-Side 1 5120.2204.0 10 Bleed Resistor Version Snap-in Front-Side 1 5120.2206.0 15 Bleed Resistor Version Snap-in Front-Side 1 5120.2207.0 - 15 A version only according UL/CSA - Type for screw-on mounting from rear side has pre-threaded holes for M3 screws Packaging unit 10 Pcs

Power Entry Modules with Line Filter520 www.schurter.com/pg06 EMC Products Accessories 0859.0048 Cord retaining kits Cord retaining strain relief Flat head, Z 0888.0021 Flat head, E 4700.0005 Flat head, G 4700.0007 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to 5120 Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to 5120 ... Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to 5120 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.