FEATURES

Hermetically sealed case to prevent entry of moisture, interior corrosion and coil freeze up Maxivision® dial for precise readings (minimize parallax reading errors) Silicone filled for reduction of pointer flutter on high vibration application and provides improved response times Custom dials Everyangle™ connection dial can be rotated 360º TYPICAL USES Offshore oil rigs Chemical and petrochemical plants Water and wastewater pressure control Pulp and paper Refineries Power General industrial HVAC Equipment skids Pharmaceutical / Biotech Food and beverages KEY BENEFITS

  • External adjustment
  • NEMA 4X/IP66 protection
  • Able to perform quick and limited span adjustments
  • 5-year limited warranty
  • All welded stainless steel construction EL Bimetal 3˝, 5˝ dial sizes SPECIFICATIONS Accuracy: ±1% of span ASME B40.200 (B40.3 Grade A) Stem Length: 2½˝ to 36˝ Dial Sizes: 3˝, 5˝ Dial Style: Maxivision®, black figures on white background Overtemperature Limits: Top of Range °F up to 250 251-550 Max. Over Temperature 100% of span 50% of span Process Connection: 1⁄2 NPT and 1⁄2 NPT union and 1⁄2 NPT adjustable union Stem diameter: 0.250˝, 0.375˝ Case & Stem: 304 Stainless steel, 316 Stainless steel Process Connection Location: 3˝, 5˝ Everyangle ™, Rear Pointer: Black Window: Polycarbonate Approvals: RoHS CAUTION Thermowells should be used on all pressurized applications over 15 psi, to protect the thermometer from corrosion or physical damage, and to facilitate removal of the thermometer without disturbing the process. MIN/MAX TEMPERATURE LIMITS Ambient –40 °F to 150 °F (–40 °C to 65 °C) of 4 EL Bimetal Thermometer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision® , Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks

ORDERING CODE Example: 30EL 60 R 060 XC4 0/200°F Dial Size and Model 30EL - 3˝ External adjust liquid filled bimetal 30EL 50EL - 5˝ External adjust liquid filled bimetal Stem and Connection 42 - 1⁄2 NPT Union (Everyangle™ only) (Allows thermometer to be rotated to desired orientation) 60 - 1⁄2 Fixed NPT 60 70 - 1⁄2 NPT Adjustable Union (Everyangle™ only) (Allows thermometer to be rotated to desired orientation) Connection Location R - Rear connection R E - Everyangle™ connection Stem Length (Consult factory for custom or longer stem length) 025 - 21⁄2˝ 040 - 4˝ 060 - 6˝ 060 090 - 9˝ 120 - 12˝ 150 - 15˝ 180 - 18˝ 240 - 24˝ 360 - 36" Options - (if choosing an option(s) must include an “X’’) X_ _ CS - Dual scale DM - Dial marking NH - SS tag YW - 316 SS construction (5˝ Everyangle™ connection) C4 - Traceable calibration certificate C4 3B - 3⁄8˝ stem diameter with 1⁄2 NPT Temperature Ranges (see table on page 3) 0/200 °F 0/200 °F of 4 EL Bimetal Thermometer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision® , Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks

ASSEMBLED IN USA BY ASHCROFT 100 150 200 250 -20 40 60 100 120 MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT -20 40 60 100 120 100 150 200 250°C MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT 100 150 200 250 -20 40 60 100 120 MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT -20 40 60 100 120 100 150 200 250 of 4 EL Bimetal Thermometer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision® , Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks Fahrenheit Inner Range Inner ºF Outer ºC Restrictions -40/120 -40/50 -40/160 -40/70 -20/120 -30/50 0/100 -20/40 4˝ min. for Everyangle™ 0/160 -20/70 4˝ min. for Everyangle™ 0/150 -20/65 4˝ min. for Everyangle™ 0/200 -20/93 0/250 -20/120 0/300 -20/150 0/350 -20/170 0/400 -20/200 0/500 -20/260 20/120 -5/50 4˝ min. for Everyangle™ 30/130 0/55 4˝ min. for Everyangle™ 30/240 0/115 50/300 10/150 50/400 10/200 50/550 10/290 Celsius Inner Range Inner ºC Outer ºF Restrictions -40/100 -40/210 -40/160 -40/320 -30/70 -20/160 -20/180 0/350 -20/120 0/250 -10/50 20/120 -10/110 20/230 0/60 30/140 4˝ minimum 0/100 30/210 0/120 30/250 0/150 30/300 0/200 30/400 0/250 30/480 0/300 30/570 10/150 50/300 Single Scale Ranges Restrictions ºF ºC Restrictions -50/250 — -40/100 -40/100 -40/160 -40/160 -20/120 -30/70 4˝ min. for Everyangle™ 0/100 -20/180 4˝ min. for Everyangle™ 0/150 -10/50 0/160 — 4˝ min. for Everyangle™ 0/200 -10/110 0/250 0/50 4˝ mimimum 0/300 0/60 4˝ mimimum 0/400 — 0/500 0/100 4˝ min. for Everyangle™ 20/120 0/120 4˝ min. for Everyangle™ 30/130 0/150 30/240 0/200 50/300 0/250 50/400 0/300 50/550 10/150

G B H S A S A C B Dial Size (Inches) Process Connection Locations A B C G H S NPT Hex. Weight (oz)(1) S - 21⁄2˝

3 Rear 23⁄32

[53] ½ 3⁄8 [10] (2) ½ 7⁄8 7

3 Everyangle™ 35⁄32

[80] ½ 3⁄8 [10] (2) ½ 7⁄8 10

5 Rear 51⁄32

[128] 19⁄32 3⁄8 [10] (2) ½ 7⁄8 16

5 Everyangle™ 51⁄32

[128] 19⁄32 17⁄8 [48] 321⁄32 [93] (2) ½ 7⁄8 25 NOTES: 1. Add 1 oz. for every 2˝ inches of stem length 2. "S" dimensions are 21⁄2, 4, 6, 9, 12, 15, 18 and 24˝ (STD.). Stem diameter is 1⁄4˝ (STD.) 3. Stem tolerance is ± 0.250˝ DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings of 4 EL Bimetal Thermometer Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision® , Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks