Features

Applications

100,000 Voltage 12 or 32 VDC Amps 3 (Resistive) Case Type Grounded Case Contact Operations Either close on rise (make) or open on rise (break), SPST (Single Pole, Single Throw) Operating Temperature +35ºF to 480ºF (+1.67ºC to 249ºC) Dielectric Strength 500 VAC, 60Hz (grounded case) terminals to case across open contacts Vibration .06DA, 10-55 Hz, 20G 20-2000 Hz Shock .75G 6ms duration (sawtooth) Military Specifications 5020-13 conforms to MIL-S-12285/1, thermal shock per MIL-STD-202, Method 107, Condition B Materials Stainless steel body and tube, compression glass seal, Mylar sleeve, epoxy fill potting, stainless or plated steel terminals, fine silver contacts

www.sensata.com Page 2 Copyright © 2020 Sensata Technologies, Inc. Code Description O Letter "O" = Open on Rise C Letter "C" = Close on Rise CONTACT OPERATION 1. The standard lead wire (materials) for different temperature ranges are as follows: A. Up to 220°F (104.4°C) = # 18 AWG standed. UL Style 1015/CSA approved. (PVC insulation, color black) B. 221°F to 350°F (105°C to 176.6°C) = #18 AWG stranded. UL Style 1199/CSA approved. (Teflon® TFE insulation, color black) C. 351°F (177.2°C) and above = #18 AWG stranded. UL style 5288/CSA approved. (Composite of Teflon®, ceramic + glass braid, color brown) 2. The marking information on each thermostat will include either the name Sensata or Airpax, contact operation (CLR) close on rise, (OPR) open on rise, top temperature and date code. TERMINAL SELECTION

www.sensata.com Page 3 Copyright © 2020 Sensata Technologies, Inc. MOUNTING THREAD SELECTION TUBE LENGTH SELECTION A B C A B C TEMPERATURE CODES AND TOLERANCE Temperature Scale Fahrenheit Celsius Fahrenheit Celsius Fahrenheit Celsius Standard Top Temperature Tolerance (code) ±5˚F (A) ±2.8˚C (A) ±10˚F (C) ±5.6˚C (C) ±25˚F (N) ±13.9˚C (N) Nominal Temperature Differential 20˚F 11.1˚C 40˚F 22.2˚C 40˚F 22.2˚C Note

  • Select any temperature in the range of 35°F to 480°F. Standard choices fall on the 5°F increments, for example 140°F, 145°F, 150°F, 155° F... up to 475°F or 480°F
  • Specify the °F temperature in the part numbering scheme as a three digit code without the ‘°F’ in the part numbe r. For example, for 200°F, put in code ‘200’
  • Bottom Temperature in °F” equals the “Top Temperature in °F” minus “Nominal Differential in °F”. For example 310°F - 30°F = 280°F Note
  • The standard tolerance for the top temperature is based on the temperature range the top temperature falls in, please refer to the temperature setting chart, and select the appropriate code for a standard top temperature tolerance
  • For bottom temperature tolerance a “Y” = minimum trip, which indicates the “reset” trip occurs at or above the lower temperature set point. Tolerance Code A B C Y ( Bottom Temp Only)

www.sensata.com Page 4 Copyright © 2020 Sensata Technologies, Inc. Contact Operation Basic Product Series Terminal Selection Tube Length Selection Top Temperature in °F Mounting Thread Selection O, C See Contact Operation Table. A, B, C, D, E, F, G, H, J See Terminal Selection Table. A, B, C See Tube Length Selection Table. See Top Temperature in °F Table. A, B, C See Mounting Thread Selection Table. ORDERING OPTIONS Example : C20ACB285B-245Y C A20 B 2 8 5 B 2 4 5 YC Close contacts on temperature rise, 5020 series, grounded case 8-32” screw terminal, 1/2-14 PTF threads, 1.635” tube length, 285°F top temperature with a ±8°F standard top tolerance and a standard 40°F differential between top and bottom temperature for temperature range of 251°F to 400°F, differential helps calculate a bottom temperature of 245°F with a standard minimum reset for contacts to close at or above the bottom temperature set point. RoHS compliant per EU directive 2002 / 95 / EC AGENCY APPROVALS AND CERTIFICATIONS Bottom Temperature (in °F) Top Temperature Tolerance Code Bottom Temperature Tolerance Code A, C, N See Temperature Codes and Tolerance Table (Available in Increments of 5°F) See Temperature Codes and Tolerance Table A, C, N, Y See Temperature Codes and Tolerance Table

www.sensata.comCopyright © 2020 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:04/27/20 Americas +1 (888) 438 2214 sensors@sensata.com Europe, Middle East & Africa +31 (74) 357 8156 temperature-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82-10-9218-1179 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 CONTACT US WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions can result in death or serious injury