thePassa P360-221 DALI UP GR Item no.: 2010341 Subject to technical changes and misprints additional information at:/product/2010341 The load data are determined with exemplary selected illuminants and are therefore typical data due to the large number of available products. Presence and motion detectors Ceiling installation indoor

Description

  • Passive infra-red presence detector for flush-mounted ceiling installation, DALI-2 certified - Rectangular detection area 360°, 30 x 4,5 m, (135 m2) at mounting height 3 m, for corridors and storage areas, with 2 individually connectable and disconnectable detection zones - 2 channels light DALI-2 addressable or 1 chanel light DALI-2 in broadcast mode - DALI-2 technology according to IEC 62386 Parts 101 and 103 - Flexible assignment of up to 2 light groups towards one DALI line - Easy, intuitive configuration of the DALI groups - Up to 2 push-button inputs - Using of conventional push-buttons for maximum design freedom - Switch or constant light control mode with stand-by function - Dimmable lighting in switch mode with stand-by function - Choice of fully or semi-automatic operation - Easy integration of an external DALI relay by an additional group e.g. for HVAC applications possible - Adjustable brightness switching value - Teach-in function via remote control or push-button - Setting of room correction factor (Automatic adjustment of brightness measurement) - Light time delay can be set - Calibrated 2 channels light measurement - Brief-presence - Self-learning time delay - Extremely easy setting of energy saving characteristics with the new „eco plus“ function - Selectable control speed - Manual override via remote control or pushbutton - Behavior after push button operation selectable (school / office) - Test mode light - Test-Mode presence - Remote-controllable - Scenes - Sensitivity adjustable - Detection area can be limited using cover clip - Extension of detection area via Master/Slave or Master/Master switching - Optimized handling by installer during assembly, wiring, commissioning 1/04/2025 Page 1 of 4

thePassa P360-221 DALI UP GR Item no.: 2010341 Subject to technical changes and misprints additional information at:/product/2010341 The load data are determined with exemplary selected illuminants and are therefore typical data due to the large number of available products. Technical data thePassa P360-221 DALI UP GR Operating voltage 110 V AC - 230 V AC Frequency 50 - 60 Hz Installation height 2 - 6 m Maximum height 15 m Minimum height 1.7 m Installation type Ceiling installation Colour Grey Switching output DALI Power consumption ≤0.4 W Light measurement Mixed light measurement Setting range brightness 10 - 3000 lx Light switch-off delay 10 s - 60 min Stand-by time light 0 s - 60 min / on Stand-by brightness 1 - 25 % thePassa P360-221 DALI UP GR Lamp types Incandescent/halogen lamps, fluorescent lamps, Energy saving lamps, LEDs Control output 100 mA Ouput light DALI-interface according to IEC SN EN 62 386 for max. 50 DALI devices Type of connection Screw terminals Max. cable cross section max. 2 x 2,5 mm² Size of concealed housing 55 mm Detection range 150 m² (30,0 x 5 m) Detection angle 360° Ambient temperature -15°C ... 50°C Type of protection IP 54 (when fitted) Connection example 1/04/2025 Page 2 of 4

thePassa P360-221 DALI UP GR Item no.: 2010341 Subject to technical changes and misprints additional information at:/product/2010341 The load data are determined with exemplary selected illuminants and are therefore typical data due to the large number of available products. Detection range for planning applications at a temperature of 21 °C Mounting height (A) Diagonally (t) Head on to (R) 2 m 56 m² | 16 m x 3.5 m 56 m² | 16 m x 3.5 m 2.5 m 88 m² | 22 m x 4 m 72 m² | 18 m x 4 m 3 m 135 m² | 30 m x 4.5 m 90 m² | 20 m x 4.5 m 3.5 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m 4 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m 4.5 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m 5 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m 5.5 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m 6 m 150 m² | 30 m x 5 m 100 m² | 20 m x 5 m Detection range according to Sensnorm IEC 63180 Mounting height (A) Diagonally (T) Head on to (R) 2.5 m 215 m² | 43 m x 5 m 62 m² | 14.8 m x 4.2 m 6 m 550 m² | 50 m x 11 m 495 m² | 45 m x 11 m 15 m 800 m² | 40 m x 20 m 600 m² | 30 m x 20 m 1/04/2025 Page 3 of 4

thePassa P360-221 DALI UP GR Item no.: 2010341 Subject to technical changes and misprints additional information at:/product/2010341 The load data are determined with exemplary selected illuminants and are therefore typical data due to the large number of available products. Scale drawings Accessories theSenda P Item no.: 9070910 theSenda S Item no.: 9070911 Surface frame 110A GR Item no.: 9070913 Masking clip Item no.: 9070921 QuickSafe Item no.: 9070531 theSenda B Item no.: 9070985 Ceiling installation box 68A Item no.: 9070992 SU 1 DALI-2 Item no.: 4940091 1/04/2025 Page 4 of 4