MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 1/10 http://www.m-system.co.jp/ Bargraph Indicators 48N Series BARGRAPH INDICATING ALARM (with 4-digit digital meter; potentiometer input) Functions & Features
- Displays a process variable in graphic bargraph of 101 LED segments
- Clear 4-digit digital meter
- Provides max. 4 alarm contact outputs
- Multi-color indicator
- LED brightness adjustment
- IP65 front cover
- Scale plate is easily replaced
- Separable terminal block m 3/h % mA
100 SET
H S P Z L M 144 (5.67) 36 (1.42) 103 (4.06) mm (inch) MODEL: 48NDM–[1][2]–[3][4]
ORDERING INFORMATION
- Code number: 48NDM-[1][2]-[3][4] Specify a code from below for each of [1] through [4]. (e.g. 48NDM-42-R/CE/D/Q)
- Bargraph scale (e.g. 0 – 100 %) (See ‘Scale Plate.’)
- Digital indicator scale (e.g. 0.0 – 130.0)
- Specify the specification for option code /Q (e.g. /C01/SET) [1] ALARM OUTPUT 0: None 2: 2 points 4: 4 points [2] BAR LED COLOR R: Red Y: Amber G: Green B: Blue 1: Multi-color (red, orange and green), Pattern 1 (See ‘External View.’) 2: Multi-color (red, orange and green), Pattern 2 (See ‘External View.’) INPUT Total resistance 100 Ω – 10 kΩ [3] POWER INPUT AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 50/60 Hz (CE marking not available) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±15 %, ripple 10 %p-p max.) [4] OPTIONS (multiple selections) Standards & Approvals blank: Without CE /CE: CE marking Bezels blank: Bezels for M-System’s 48 Series panel cutout /D: Bezels for DIN panel cutout /F: Bezels for Fuji Electric's PAJ, PAK, PBA panel cutout Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9445) BEZEL OPTION Bezels are used to adapt the 48N Series to an existing panel cutout. In order to replace M-System’s 48 Series products, use the one attached to the 48N Series as standard. When the existing panel is cut according to DIN standard, specify ‘/D’ suffix code. For a new installation, no bezel is required. Please refer to ‘Mounting Requirement’ and mount the 48N directly. Ingress protection is invalid when the 48N is mounted with a bezel, or when multiple modules are stacked side by side.
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 2/10 http://www.m-system.co.jp/ SPARE PARTS
- Scale plate GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP65; applicable to the front panel for single unit mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N·m) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Zero adjustment: 0 – 30 % of total resistance (front) Span adjustment: 70 – 100 % of total resistance (front) Scale plate: Flame resistant resin (white scale & characters on black base) H & L alarm output delay: 0 sec. (factory setting; fieldselectable between 0 and 15 sec. by 1 sec. increments) Setpoint adjustment 2 points: H [L setpoint ] to 100 % L 0 to [H setpoint] or No alarm trip 4 points: HH [H setpoint] to 100 % H [L setpoint] to [HH setpoint] L [LL setpoint] to [H setpoint] LL 0 to [L setpoint] or No alarm trip Alarm deadband (hysteresis): 1 % Setting: (Front button)
- Zero and span adjustments
- Alarm setpoint
- Others (Refer to the instruction manual for details) Read rate: 10/s Moving average sample number: 4 (factory setting; field selectable among 1, 2, 4, 8 or 16) LED brightness adjustment: 7 levels ■ BARGRAPH LED: 101-segment LED, 100 mm (3.96”) long, 3.00 mm (.12”) wide Display range: 0 to 100 (scaling function not available) (0 % or 100 % position bar blinks when over range) Scale: Two different scales available for single bargraph Characters: Max. 4 characters including decimal point and negative sign Divisions: Min. 22, max. 100 Engineering unit: Max. 6 characters ■ DIGITAL DISPLAYS LED: 7-segment red LED, character 8 mm (.31”) high Number of digits: 4 digits Setting range: -1999 to 9999 (Min. 3 significant digits) Minimum scale value: 100 (3 digits, the decimal point position disregarded) Scaled range: The range between -1999 to 9999 and -15 to +115 % of input span (The indicator blinks when the input is out of the range) Decimal point position: 10–1, 10–2, 10–3 or none Zero indication: Higher-digit zeros are suppressed Engineering unit: Max. 6 characters on scale plate INPUT SPECIFICATIONS Minimum span: 70 % of total resistance Excitation: 0.5 V DC OUTPUT SPECIFICATIONS ■ Alarm Output: Relay contact Rated load: 250 V AC @1 A (cos ø = 1)
30 V DC @5 A (resistive load)
Maximum switching voltage: 250 V AC, 220 V DC Maximum switching power: 380 VA, 150 W Minimum load: 5 V DC @100 mA Mechanical life: ≥ 5 × 108 cycles (rate 180 cycles/min.) 0 50 100 Input (%) L Setpoint H Setpoint H Output L Output
- Alarm Output Code 2 Alarm Trip Operation Terminal No. in parentheses (7–8)ON (12 –14 )ON (13 –14 )ON (7–9)ON 0 50 100 Input (%) L H HH Output LL Output H Output L Output HH LL
- Alarm Output Code 4 Terminals 7 – 9, 13 – 14 turn on at a loss of power. Terminals 7 – 9, 13 – 14 turn on at a loss of power. (7–8)ON (7–9)ON (7–10 )ON (11 –14 )ON (12 –14 )ON (13 –14 )ON
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 3/10 http://www.m-system.co.jp/ INSTALLATION Power Consumption
- AC: Approx. 5.5 VA at 100 V with max. load Approx. 7 VA at 200 V with max. load Approx. 8 VA at 264 V with max. load
- DC Approx. 3.5 W at 20.4 V with max. load Approx. 3.5 W at 24 V with max. load Approx. 3.5 W at 27.6 V with max. load Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb) PERFORMANCE in percentage of span Accuracy Bargraph: ±1 % ±1 digit Digital indicator: ±0.5 % ±1 digit Temp. coefficient: ±0.015 % of FS/°C (±0.008 % of FS/°F) Response time: ≤ 0.5 sec. (moving average sample number set to 4) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Installation Category II (power) Pollution Degree 2 Input to output to power: Reinforced insulation (300 V) RoHS Directive EN 50581
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 4/10 http://www.m-system.co.jp/ SCALE PLATE
- Type 1: 1.1 Scale Span < 1.3 Number of divisions: 22 to 25.9 Scale: Starts at 0, increments by 0.02 / 0.2 / 2 / 20 / 200. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Long (4 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 600 400 200 -200 -4000.2 -600 0.4 0.6 0.8 1.0 1.2 1.29 ■ WHAT MUST BE SPECIFIED WHEN ORDERING Following two methods can specify scale plate. a) Using ‘Scale Plate Designer’ Access ‘Design Scale Plate’ in the M-System web site (http://www.m-system.co.jp/english). Scale plate can be designed in this web site. By function below, it can be easy to create standard design or original design. [Design Automatically] Entering Minimum, Maximum, and Unit allows to create automatically a scale plate. Maximum created scale division number is ’54.9’. Use [Specify Division Number], if division number more than ’54.9’ is required (Maximum 100 division). [Specify Division Interval] Division Interval can be specified according to the application. [Specify Division Number] It is available to create originally with scale division number, length of line, position, character size, font and detailed position. After designing is completed, register code is issued. Place the order with this code. Once scale plate is designed, it is recorded. The register code can be used any number of times. b) Specifying scale range and display unit when placing the order It is available to create by specifying scale range and display unit for right and left. Regarding design of scale plate such as division number, length of division number line, and character font, they are same as above [Design Automatically], M-System designs them. ■ DESIGNING BY ‘DESIGN AUTOMATICALLY’ How ‘Design Automatically’ creates scale design is described succinctly below. ■ TYPES OF DIVISIONS Five (5) types of divisions are used depending upon the scale span, which determined by the following equation: Scale Span = (Max. range value – Min. range value) x 10 where n = integer (used to limit the calculated scale span to the minimum of 1.1, below 11.0.) The number of divisions is automatically determined by the scale span. n
- Type 2: 1.3 Scale Span < 2.0 Number of divisions: 26 to 39.9 Scale: Starts at 0, increments by 0.03 / 0.3 / 3 / 30 / 300. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Medium, Short, Long (6 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 0.3 0.6 0.9 1.2 1.5 1.8 0.6 0.3 -0.3 -0.6 -0.8 0.81.99 120 130
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 5/10 http://www.m-system.co.jp/ 300 250 cm SET S P Z L LL HH H M 200 150 100 [Example] : Bargraph range 0 to 300 cm (Type 4) Digital indicator range 0.00 to 6.75 m3 (Type 4) Left scale range: 0 – 300 Left scale unit (bargraph): cm Right scale: None Digital indicator unit: m3
- Type 3: 2.0 Scale Span < 2.6 Number of divisions: 40 to 51.9 Scale: Starts at 0, increments by 0.05 / 0.5 / 5 / 50 / 500. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Medium, Short, Medium, Short, Medium, Short, Long (10 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 120 100 -50 -100 -120 0 0 0.5 1.5 2.59
- Type 4: 2.6 Scale Span < 5.5 Number of divisions: 26 to 54.9 Scale: Starts at 0, increments by 0.05 / 0.5 / 5 / 50 / 500. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Medium, Medium, Medium, Medium, Long (5 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 250 200 150 100 -50 -100 -150 -200 -250 0 0 0.5 1.5 2.5 3.5 4.5 5.49 100 150 200 250 260
- Type 5: 5.5 Scale Span < 11.0 Number of divisions: 27.5 to 54.9 Scale: Starts at 0, increments by 0.01 / 0.1 / 1 / 10 / 100 / 1000. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Medium, Medium, Medium, Medium, Long (5 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 0.5 0.4 0.3 0.2 0.1 -0.1 -0.2 -0.3 -0.4 -0.5 100 200 300 400 500 550 10.9
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 6/10 http://www.m-system.co.jp/ EXTERNAL VIEW -10 -20 -30 -40 -50 m 3/h % mA S P Z SET (ENTER) Button Color Setpoint 2 Adj. & Function Span Adj. & Setting Decimal Point Position, Moving Average, Brightness Adj. Zero Adj. & Setting Color Setpoint 1 Adj. & Function Setting UP Button, Switcing Detailed Settings Mode & Setting Selector Setting DOWN Button, Switcing Detailed Settings Digital Indicator Setpoint 2 Value Setpoint 1 Value PV Indicator M Note: Setpoint 1 or 2 provided only for the multi-color bar type. ■ ALARM OUTPUT CODE 0: None • Bar Color Patterns Pattern 1 (Bar LED color code 1) orange orange green orange Input < L L < Input < H H < Input green redH L Pattern 2 (Bar LED color code 2) orange green green red red redH L -10 -20 -30 -40 -50 m 3/h % mA H S P Z L SET (ENTER) Button H Setpoint Adj. & Alarm Function Span Adj. & Setting Decimal Point Position, Moving Average, Brightness Adj. Zero Adj. & Setting L Setpoint Adj. & Alarm Function Setting UP Button, Switcing Detailed Settings Mode & Setting Selector Setting DOWN Button, Switcing Detailed Settings H Setpoint L Setpoint PV Indicator M -10 -20 -30 -40 -50 m 3/h % mA H S P Z L SET (ENTER) Button HH Setpoint Adj. & Alarm Function H Setpoint Adj. & Alarm Function Span Adj. & Setting Decimal Point Position, Moving Average, Brightness Adj. Zero Adj. & Setting L Setpoint Adj. & Alarm Function LL Setpoint Adj. & Alarm Function Setting UP Button, Switcing Detailed Settings Mode & Setting Selector Setting DOWN Button, Switcing Detailed Settings HH Setpoint H Setpoint L Setpoint LL Setpoint PV Indicator HH LL M ■ ALARM OUTPUT CODE 2: 2 points Digital Indicator ■ ALARM OUTPUT CODE 4: 4 points Digital Indicator
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 7/10 http://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 75 (2.95) 103 (4.06) 10 (.39) 18 (.71) 16–M3 SCREW TERMINALS 2–M3 SCREWS 144 (5.67) 137.5 (5.41) 4 *1 (.16) 100 (3.94) Rounded corners for the option /D ■ OPTION /D BEZEL*3 *1. Space required when replacing the scale plate. *2. Used for the existing panel cutout of M-System 48 Series (38 × 139.5 mm). *3. Used for the existing DIN panel cutout (33 × 138 mm) *4. Used for the existing panel cutout of Fuji Electric PAJ, PAK, PBA (44 × 138 mm), etc. ■ STANDARD BEZEL*2 10.4 (.41) 7.5 (.30) 3.9 (.15) 136.5 (5.37) 144 (5.67) 11.4 (.45) 7.5 (.30) 4.9 (.19) 136.5 (5.37) 144 (5.67) 8.5 (.33) 10.4 (.41) 7.5 (.30) 136.5 (5.37) 144 (5.67) ■ OPTION /F BEZEL *4
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 8/10 http://www.m-system.co.jp/ PANEL CUTOUT unit: mm 138 31.5 Note 1: Observe at the minimum of 3 cm above and below the units for heat dissipation. Note 2: No bezel is needed when the panel is cut according to the above drawings. Panel thickness: 1.6 – 8.0 mm ■ SINGLE MOUNTING (Conform to degree of protection IP65) 138 L Panel thickness: 1.6 – 8.0 mm (N : number of units) ■ CLUSTERED MOUNTING (Not conform to degree of protection IP65) 61.5 min.
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 9/10 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Ry 12 POWER U(+) V(–) LLa 11 La LLb Lc, LLc HHa
7 Hc, HHc
■ ALARM OUTPUT CODE 4: 4 points Digital Computation POWER U(+) V(–) La Lb Lc Ha 7 Hc Hb H OUTPUT L OUTPUT ■ ALARM OUTPUT CODE 2: 2 points Display / Setting Digital Computation POWER U(+) V(–) ■ ALARM OUTPUT CODE 0: None Display / Setting Digital Computation Display / Setting Low Drift Amplifier POTENTIOMETER max. min. Excitation Volt. Generator Low Drift Amplifier POTENTIOMETER max. min. Excitation Volt. Generator Low Drift Amplifier POTENTIOMETER max. min. Excitation Volt. Generator Ry Ry Ry Ry Ry
- DC Powered ■ Relay Protection
- AC Powered LOAD Inductive Load (Coil) Varistor or Spark Quenching Circuit U LOAD Inductive Load (Coil) Diode, Varistor or CR Circuit
MODEL: 48NDM 48NDM SPECIFICATIONS ES-9445 Rev.13 Page 10/10 http://www.m-system.co.jp/ Specifications are subject to change without notice.