480300 Ver. 1.5 4/01 User's Manual Phase Rotation Tester Model 480300 Introduction Congratulations on your purchase of Extech’s Phase Rotation Tester. This professional meter, with proper care, will provide years of safe reliable service. Specifications Signal Input Voltage 100VAC up to 660VAC max., 3 minute limit over 500VAC. Signal Frequency Range 45 to 70 Hz. Circuit Structure All electronic Operating Temperature 0oC to 50oC (32oF to 122oF) Operating Humidity Less than 90% RH. Fuse Rating 250mA / 250V Power Supply Uses connection to external equipment for power Power Consumption approx. 7mA @ 500V. Dimension 3.9 x 1.9 x 1.0” (100 x 50 x 25mm) Weight 0.33 lbs. (150g) Standard Accessories 40cm test leads with alligator clips and Instruction Manual Operation The Phase Rotation function determines if the 3 phases are live and the direction a motor will turn if connected as indicated in Table 1 below. 1. Connect the three test leads to the 3 phase AC power source 2. Observe that all three lights (L1, L2, L3) are active 3. Observe the directional indication lights. 4. If the direction indicated is counter-clockwise, reconnect any two wires until the clockwise indicator is lighted. 5. If the clockwise indicator is lighted, label the power source "L1, L2, L3" (R, S, T) L1 L2 L3 R S T

480300 Ver. 1.5 4/01

3 Phase Tester Indication Table

3 Phase Tester Indication

Direction Indication L1 L2 L3 Clockwise Counter Clockwise L1 No Connection L2 No Connection L3 No Connection Light ON = Light OFF = Fuse Replacement 1. Replace the fuse when the indicators fail to light. 2. Open the case and replace the 250mA / 250V fuse. 3. Reinstall the case. Calibration and Repair Services Extech offers complete repair and calibration se rvices for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Copyright © 2001 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. Tech Support Hotlines 781-890-7440 ext. 200 extech@extech.com www.extech.com