47LV MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 1/8 https://www.m-system.co.jp/ Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 ½ digit, LED display type) Functions & Features
- 4 ½ digit DC input digital panel meter
- 1/8 DIN size
- Moving average function to suppress the display flickering
- Scaling, forced zero, low-end cutout
- Max. and Min. value display
- Safety terminal cover tethered to the device with a strap
- IP66 front panel
- Separable terminal block Alar m/ Scale/ Max/Min Shift Up Zro Spn D/P Tch Fnc Min Max HH H P L LL (1.89) mm (inch) 96 (3.78) 98.5 (3.88)
ORDERING INFORMATION
- Code number: 47LV-1[1][2][3][4]-[5][6] Specify a code from below for each of [1] through [6]. (e.g. 47LV-101G-M2/Q)
- Specify the specification for option code /Q (e.g. /C01/S01/SET) [1] INPUT 1: ±10 V, ±5 V, 0 – 5 V, 1 – 5 V 0 – 20 mA, 4 – 20 mA 3: ±200 V, ±100 mA 4: ±100 μA (CE not available) 5: ±2 A, ±1 A (CE not available) 6: ±700 V (CE not available) [2] DC OUTPUT 0: Without Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) Voltage 3: 0 – 1 V DC (Load resistance 1000 Ω min.) (CE not available) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points [4] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White [5] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [6] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9502) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front of the panel meter mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N·m) Screw terminal: Nickel-plated steel (standard) or stainless
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 2/8 https://www.m-system.co.jp/ steel Housing material: Flame-resistant resin (gray) Isolation: Input to DC output to HH output or H output to L output or LL output to power Setting: (Front button)
- Scaled range
- Input type
- Alarm setpoint
- Hysteresis (deadband)
- Moving average
- Others (Refer to the instruction manual for details) Read rate: 40 times/sec. (25 msec.) Averaging: None or moving average Lockout setting: Prohibiting certain operations; protecting settings DISPLAY Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED Display range: -19999 to 19999 Decimal point position: 10–1, 10–2, 10–3, 10–4 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: ‘-19999’ or ‘19999’ blinking for display values out of the display range. ‘S.ERR’ and ‘Min’ or ‘Max’ blinking when the input signal is out of the usable range. Alarm status indication LL indicator: Green LED turns on when the LL alarm is tripped. L indicator: Green LED turns on when the L alarm is tripped. H indicator: Red LED turns on when the H alarm is tripped. HH indicator: Red LED turns on when the HH alarm is tripped. P indicator: Amber LED turns on when none of the other alarms is tripped. Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’ does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Function indicators: Zro, Spn, D/P, Tch, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mV, V, kV, μA, mA, A, kA, mW, W, kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec, m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h, N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J, kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc. INPUT SPECIFICATIONS Default setting Input code 1: Measuring range ±10 V Input code 2: Measuring range ±1 V Input code 3: Measuring range ±200 V Input code 4: Measuring range ±100 μA Input code 5: Measuring range ±2 A Input code 6: Measuring range ±700 V Overload capacity Input code 5: ±3 A for 10 sec., ±2.4 A continuous Input code 6: ±1000 V for 10 sec., ±840 V continuous ■ INPUT CODE: 1 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE V10 ±10 V -11 – +11 V ≥ 1 MΩ V5 ±5 V -5.5 – +5.5 V ≥ 1 MΩ V0-5 0 – 5 V -0.3 – +5.3 V ≥ 1 MΩ V1-5 1 – 5 V 0.7 – 5.3 V ≥ 1 MΩ A0-2 0 – 20 mA -2 – +22 mA approx. 10 Ω A4-2 4 – 20 mA 2 – 22 mA approx. 10 Ω ■ INPUT CODE: 2 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE V1 ±1 V -1 .1 – +1 .1 V ≥ 1 MΩ V01 ±100 mV -110 – +110 mV ≥ 1 MΩ V001 ±10 mV -11 – +11 mV ≥ 1 MΩ A1 ±1 mA -1 .1 – +1 .1 mA approx. 100 Ω ■ INPUT CODE: 3 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE V200 ±200 V -220 – +220 V ≥ 1 MΩ A100 ±100 mA -110 – +110 mA approx. 10 Ω ■ INPUT CODE: 4 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE A01 ±100 μA -110 – +110 μA approx. 1 kΩ ■ INPUT CODE: 5 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE A2-2 ±2 A -2.2 – +2.2 A approx. 0.1 Ω A1-1 ±1 A -1 .1 – +1 .1 A approx. 0.1 Ω ■ INPUT CODE: 6 TYPE IND MEASURING RANGE OPERATIONAL RANGE INPUT IMPEDANCE V700 ±700 V -770 – +770 V ≥ 1 MΩ OUTPUT SPECIFICATIONS ■ DC Output
- DC Current Operational range: -5 – +105 %
- DC Voltage Operational range: -5 – +105 % ■ Alarm Output: Relay contact
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 3/8 https://www.m-system.co.jp/ Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 10 mA Mechanical life: ≥ 5 × 106 cycles (rate 180 cycles/min.) INSTALLATION Power consumption
- AC: Approx. 6.5VA
- DC: Approx. 3 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb) PERFORMANCE Accuracy Display: ±0.1 % ± 1 digit ± 0.2 % ± 1 digit for ± 10 mV range Output: ±0.1 % (DC output = display + output) Temp. coefficient: ± 0.015 %/°C (± 0.008 %/°F) ±0.03 %/°C (±0.02%/°F) for ±10 mV range Input resolution: Max. 16 bits Output resolution: Max. 14 bits Response time: ≤ 0.5 sec. (alarm output: 0 – 100 % at 90 % setpoint) ≤ 0.5 sec. (DC output: 0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to DC output to HH output or H output to L output or LL output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (alarm output) Installation Category II (power) Pollution degree 2 Input or DC output to alarm output to power: Reinforced insulation (300 V) Input to DC output: Basic insulation (300 V) RoHS Directive Protection against access to the terminal blocks: Finger protection (VDE 0660-514)
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 4/8 https://www.m-system.co.jp/ EXTERNAL VIEW (4) Max/Min Button (5) Alarm/ Button (6) Scale/ Button (7) Shift Button (8) Up Button (1) Main Display (2) Alarm Indicators (3) Function Indicators Alarm/ Scale/Max/Min Shift Up Zro HH H P L LL Spn D/P Tch Fnc Min Max
- COMPONENT IDENTIFICATION No. COMPONENT FUNCTION (1) Main display Indicates present values, setting values and status of the unit. (2) Alarm indicators Indicate alarm status of the input signal. (3) Function indicators Indicate the status in each setting mode. (4) Max/Min button Used to switch the main display to show the present values, maximum values or minimum values etc. (5) Alarm/ button Used to con/f_i rm alarm setting value and to move on to the alarm and other setting modes; or to shift through setting items in each setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status of each setting mode and shift through display digits in each setting mode. (8) Up button Used to change setting values, to execute/cancel Forced Zero or to select setting values. Note: Refer to the operating manual for details on each function.
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 5/8 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 96 (3.78) 48 (1.89) 103 (4.06) 95 (3.74) 2 (.08) 47 (1.85) 98.5 (3.88) 45 (1.77) 91.5 (3.60) 4–M3 SCREW ■ REAR VIEW
- No Alarm Output • Alarm Output ■ FRONT VIEW ■ SIDE VIEW ■ TOP VIEW 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20–M3 SCREW TERMINAL 2–M3 SCREW 10–M3 SCREW TERMINAL 6.6 (.26)
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 6/8 https://www.m-system.co.jp/ MOUNTING REQUIREMENTS unit: mm + 0.8 – 0 + 0.6 – 0 min. 120 min. 75 Panel thickness: 1.6 to 8.0 mm
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 7/8 https://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM POWER U(+) V(–) ■ ALARM OUTPUT CODE 1: N.O. contact, 4 points A/D Converter Digital Computation Ry Ry Ry Ry Display / Setting INPUT* POWER U(+) Lc (COM ) Lb (NC) La (NO) Hc (COM ) Hb (NC) Ha (NO) V(–) ■ ALARM OUTPUT CODE 2: SPDT contact, 2 points A/D Converter Digital Computation Ry Ry Lc, LLc LLa La Hc, HHc Ha HHa Display / Setting INPUT* LL OUTPUT L OUTPUT H OUTPUT L OUTPUT H OUTPUT HH OUTPUT POWER U(+) V(–) ■ ALARM OUTPUT CODE 0: No alarm output A/D Converter Digital Computation Display / Setting INPUT* DC OUTPUT Isolation Output Driver DC OUTPUT Isolation Output Driver DC OUTPUT Isolation Output Driver LOAD Inductive Load (Coil) Varistor or CR Circuit
- DC Powered LOAD Inductive Load (Coil) Diode, Varistor or CR Circuit ■ Relay Protection
- AC Powered Note: The section enclosed by broken line is only with DC output option. I COM – V I COM – – – + 1 * Input shunt resistor incorporated for current input.
- Input code: 1, 2 • Input code: 3 • Input code: 4 • Input code : 5, 6 U
MODEL: 47LV 47LV SPECIFICATIONS ES-9502 Rev.14 Page 8/8 https://www.m-system.co.jp/
- Input Terminal Assignments INPUT TYPE MEASURING INPUT (indicator) RANGE TERMINALS V200 ±200V 1 – 4V10 ±10V V5 ±5V V1 ±1V V01 ±100mV 2 – 4V001 ±10mV INPUT TYPE MEASURING INPUT (indicator) RANGE TERMINALS V0-5 0 – 5V 2 – 4 V1-5 1 – 5V A100 ± 100mA 3 – 4 A1 ±1mA A0-2 0 – 20mA A4-2 4 – 20mA A2-2 ±2A A1-1 ±1A V700 ±700V A01 ±100μA Specifications are subject to change without notice.