47LPA MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 1/8 https://www.m-system.co.jp/ Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features
- 4 ½ digit digital panel meter
- 1/8 DIN size
- Accepts a pulse train input to measure rotation count or period
- Scaled reading representing speed (m/s), rotation (rpm) and other counts
- Alarm tone optional
- Max. and Min. value display
- IP66 front panel
- Separable terminal block
- Rear terminal cover for safety strapped to the meter Alar m/ Scale/ Max/Min Shift Up Zro Spn D/P Tch Fnc Min Max HH H P L LL (1.89) mm (inch) 96 (3.78) 98.5 (3.88) MODEL: 47LPA-1[1][2][3]-[4][5]
ORDERING INFORMATION
- Code number: 47LPA-1[1][2][3]-[4][5] Specify a code from below for each of [1] through [5]. (e.g. 47LPA-1A1G-M2/B/Q)
- Specify the specification for option code /Q (e.g. /C01/S01/SET) INPUT 1: Open collector or voltage pulse [1] DC OUTPUT 0: Without Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) Voltage 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [5] OPTIONS (multiple selections) Alarm Tone blank: Without /B: With (selectable only with alarm output) Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9515) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front of the panel meter mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N·m) Screw terminal: Nickel-plated steel (standard) or stainless steel
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 2/8 https://www.m-system.co.jp/ Housing material: Flame-resistant resin (gray) Isolation: Input to DC output to HH output or H output to L output or LL output to power Setting: (Front button)
- Scaled range
- Input type
- Alarm setpoint
- Hysteresis (deadband)
- Others (Refer to the instruction manual for details) Lockout setting: Prohibiting certain operations; protecting settings DISPLAY Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED Input indication: ‘D/P’ turns on for 1 second after a valid pulse train has been detected (applied to 1/100 scaled signal for the input ranges F10K, F0.1M). ‘Tch’ turns on with control input. Display range: -19999 to 19999 Decimal point position: 10–1, 10–2, 10–3, 10–4 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: ‘-19999’ or ‘19999’ blinking for display values out of the scaled range. ‘S.ERR’ and ‘Max’ blinking when the input signal is out of the usable range. Alarm status indication LL indicator: Green LED turns on when the LL alarm is tripped. L indicator: Green LED turns on when the L alarm is tripped. H indicator: Red LED turns on when the H alarm is tripped. HH indicator: Red LED turns on when the HH alarm is tripped. P indicator: Amber LED turns on when none of the other alarms is tripped. Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’ does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Function indicators: Zro, Spn, D/P, Tch, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mV, V, kV, μA, mA, A, kA, mW, W, kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec, m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h, N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J, kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc. INPUT SPECIFICATIONS Sensor excitation: 12 V DC ±10 %, 30 mA Current limit protection at approx. 60 mA Frequency range: 0 – 0.01 Hz through 100 kHz A wave that has constant frequency and variable duty ratio cannot be measured. Time period range: 0 – 1 sec. through 100 sec. Minimum pulse width requirements: 5 μsec. for both ON and OFF Default setting: 0 – 100 kHz ■ Open Collector Detecting voltage/current: Approx. 8 V DC @ 1.6 mA Detecting levels: ≤ 300 Ω / 0.6 V for ON; ≥ 10 kΩ / 4.5 V for OFF ■ Voltage Pulse Voltage range: 0 – 5 through 26.4 V ±5 – ±26.4 V (equal amplitude at both poles, or ±10 V min. with frequency ≥ 50 kHz) Waveform: Square (detecting sinking pulse edges) Input impedance: ≥ 10 kΩ Low level: -26.4 – 0.6 V DC High level: 4.5 – 26.4 V DC ■ Control Input: Halt measuring Detecting time: ≥ 200 msec. Detecting levels: 4.5 – 26.4 V or short circuit across the terminals 1 and 5 for ON; -26.4 – 0.6 V for OFF OUTPUT SPECIFICATIONS ■ DC Output
- DC Current Operational range: -5 – +105 %
- DC Voltage Operational range: -5 – +105 % ■ Alarm Output: Relay contact Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 10 mA Mechanical life: ≥ 5 × 106 cycles (rate 180 cycles/min.) INSTALLATION Power consumption
- AC: Approx. 6.5VA
- DC: Approx. 3 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb)
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 3/8 https://www.m-system.co.jp/ PERFORMANCE Accuracy Display: ±0.1 % or ±1 digit Output: ±0.1 % (DC output = display + output) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Output resolution: Max. 14 bits Response time: [One input cycle + 0.5 sec.] or less (alarm output: 0 – 100 % at 90 % setpoint) [One input cycle + 0.5 sec.] or less (DC output: 0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to DC output to HH output or H output to L output or LL output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (alarm output) Installation Category II (power) Pollution degree 2 Input or DC output to alarm output to power: Reinforced insulation (300 V) Input to DC output: Basic insulation (300 V) RoHS Directive Protection against access to the terminal blocks: Finger protection (VDE 0660-514)
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 4/8 https://www.m-system.co.jp/ EXTERNAL VIEW (4) Max/Min Button (5) Alarm/ Button (6) Scale/ Button (7) Shift Button (8) Up Button (1) Main Display (2) Alarm Indicators (3) Function Indicators Alarm/ Scale/Max/Min Shift Up Zro HH H P L LL Spn D/P Tch Fnc Min Max
- COMPONENT IDENTIFICATION No. COMPONENT FUNCTION (1) Main display Indicates present values, setting values and status of the unit. (2) Alarm indicators Indicate alarm status of the input signal. (3) Function indicators Indicate the status in each setting mode. (4) Max/Min button Used to switch the main display to show the present values, maximum values or minimum values etc. (5) Alarm/ button Used to con/f_i rm alarm setting value and to move on to the alarm and other setting modes; or to shift through setting items in each setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status of each setting mode and shift through display digits in each setting mode. (8) Up button Used to select setting values in each setting mode. Note: Refer to the operating manual for details on each function.
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 5/8 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 96 (3.78) 48 (1.89) 103 (4.06) 95 (3.74) 2 (.08) 47 (1.85) 98.5 (3.88) 45 (1.77) 91.5 (3.60) 4–M3 SCREW ■ REAR VIEW
- No Alarm Output • Alarm Output ■ FRONT VIEW ■ SIDE VIEW ■ TOP VIEW 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20–M3 SCREW TERMINAL 2–M3 SCREW 10–M3 SCREW TERMINAL 6.6 (.26)
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 6/8 https://www.m-system.co.jp/ MOUNTING REQUIREMENTS unit: mm + 0.8 – 0 + 0.6 – 0 min. 120 min. 75 Panel thickness: 1.6 to 8.0 mm
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 7/8 https://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Inductive Load (Coil) Varistor or Spark Quenching Circuit LOAD Inductive Load (Coil) LOAD Diode, Varistor or CR Circuit POWER U(+) V(–)
- DC Powered ■ Relay Protection
- AC Powered ■ Input Connection Example
- Open Collector ■ ALARM OUTPUT CODE 1: N.O. contact, 4 points Ry Ry Ry Ry POWER U(+) Lc (COM ) Lb (NC) La (NO) Hc (COM ) Hb (NC) Ha (NO) V(–) ■ ALARM OUTPUT CODE 2: SPDT contact, 2 points Ry Ry Lc, LLc LLa La Hc, HHc Ha HHa LL OUTPUT L OUTPUT H OUTPUT L OUTPUT H OUTPUT HH OUTPUT POWER U(+) V(–) ■ ALARM OUTPUT CODE 0: No alarm output Digital Computation Display / Setting Control Input Sensor Excitation Scaler Input Circuit DC OUTPUT Isolation Output Driver Digital Computation DC OUTPUT Isolation Output Driver Digital Computation DC OUTPUT Isolation Output Driver Note 1: The section enclosed by broken line is only with DC output option. Note 2: Chattering input signals cannot be measured accurately. Add a capacitor (10000 pF) or similar devices to the input terminals to eliminate the input signals’ instability. EXC+ OC JP INP+ COM– DI+ Control Input Sensor Excitation Scaler Input Circuit3 Control Input Sensor Excitation Scaler Input Circuit3 *1. Close across the terminals for open collector. Refer to the figure below. SENSOR EXCITATION INPUT CONTROL INPUT SHORT- CIRCUIT*1 EXC+ OC JP INP+ COM– DI+ SENSOR EXCITATION INPUT CONTROL INPUT SHORT- CIRCUIT*1 EXC+ OC JP INP+ COM– DI+ SENSOR EXCITATION INPUT CONTROL INPUT SHORT- CIRCUIT*1 5k Ω COM Short U *2. For detailed connection of CONTROL INPUT, refer to the operating manual (EM-9515-B).
MODEL: 47LPA 47LPA SPECIFICATIONS ES-9515 Rev.13 Page 8/8 https://www.m-system.co.jp/ Specifications are subject to change without notice.