4790_21 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Cord Connectors (Rewireable) 4790https://www.schurter.com /PG07 Connectors IEC Connector C19, Rewireable, Angled Rewireable connector Example with assembled cable See below: Approvals and Compliances C19 70° C
Description
- Rewireable connector for cable 90° entry : Screwing cable terminal - Connector , Pin temperature 70 °C , Protection class I - Screw clamps Characteristics - Suitable for use in equipment according to IEC/UL 62368-1 References Substitute for type 1651 Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 16 A / 250 VAC; 50 Hz Ratings UL/CSA 20 A / 250 VAC; 60 Hz Dielectric Strength > 2 kVAC between L-N > 2 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- rature -25 °C to 70 °C Protection against electric shock Suitable for appliances with protection class I acc. to IEC 61140 Terminal Screw Material: Housing Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet C19 acc. to IEC 60320-1 UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 4790 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40040046 UL Approvals UL UL File Number: E96454 CCC Approvals CCC CCC Certificate Number: 2014010204709145
Cord Connectors (Rewireable)4790 https://www.schurter.com /PG07 Connectors Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimensions [mm] A 22.2 41.1 31.6 52.1 B 1) Cut strain relief 8 (10) mm here for 10 mm cable A: Strain relief 8 mm: 76.1 mm B: Strain relief 10 mm: 71.1 mm All Variants Color Recommended cable diameter Max. wire size L = Length of cable guard Order Number black 8 mm 3 x 1.5 mm² / 3 x 14 AWG 76.1 mm 4790.1100 █ black 10 mm 3 x 1.5 mm² / 3 x 14 AWG 71.1 mm 4790.1200 █ █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Max. torque for screws: Terminals: 0.8 Nm, Cable clamps: 0.8 Nm, Cover: 0.5 Nm
Cord Connectors (Rewireable) 4790https://www.schurter.com /PG07 Connectors Packaging unit 50 Pcs Mating Inlets/Plugs Category / Description Appliance Inlet Overview complete 1601, Mounting: Screw, Solder terminal straight, IP20, Appliance Inlet, C20 1601 4793, Mounting: Snap-in, IP30, Appliance Inlet: IEC C20, Suitable for appliances with protection class I or II 4793 IEC Appliance Inlet C20, Screw-on Mounting, Front Side, Solder, Quick-connect or Screw Terminal 1621 IEC Inlet Filter Overview complete IEC Appliance Inlet C20 with Filter, ECO design, front or rear side Mounting 5130 C20F, Mounting: Screw Front-/Rear-Side, Filter: Standard and Medical Version, Capacitor: X2, 16 A, Solder / quick connect / wires (stranded), prewired C20F C22F, Mounting: Screw Front-/Rear-Side, Filter: Standard and Medical Version, Capacitor: X2, 16 A, Solder / quick connect / wires (stranded), prewired C22F Plug Overview complete 4796, Mounting: Power Cord, Cable, Plug: IEC I 4796 4789, Mounting: Power Cord, Screw, Plug: IEC I 4789 Power Entry Module Overview complete EC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 2-pole, Appliance Inlet IEC C20, Quick connect terminals 6.3 x 0.8 mm, prewired EC11 Power Entry Module with line filter Overview complete IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed) EF12 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 16.09.2021