Cord Connectors (rewireable) 4772https://www.schurter.com /PG07b Connectors IEC Connector C15A, Rewireable, Angled See below: Approvals and Compliances C15 A 155° C
Description
- Connector : Screwing cable terminal - Pin temperature 155 °C , Protection class I , Cable - Cable guard included Unique Selling Proposition - Wide range of approvals - Easy cable assembly References Substitute for type 0112 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 10 A / 250 VAC; 50 Hz Ratings UL/CSA 10 A / 250 VAC; 60 Hz Dielectric Strength > 3 kVAC between L-N > 1.5 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- rature -25 °C to 155 °C IP-Protection from front side IP 20 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I acc. to IEC 61140 Terminal Screw clamps Material: Housing Phenolic, black appliance inlet/-outlet C15A acc. to IEC 60320-1 UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 155 °C, 10 A, Protection Class I Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 4772 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40045962 UL Approvals UL UL File Number: E96454 CQC Approvals CQC CCC Certificate Number: 2014010204709153 METI Approvals METI Japan Electrical Safety and Environment technology Laboratories
Cord Connectors (rewireable)4772 https://www.schurter.com /PG07b Connectors Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimensions [mm] 49.8 40.5 A B 1) Cut strain relief 8 (10) mm here for 10 mm cable A: Strain relief 8 mm: 75.5 mm B: Strain relief 10 mm: 70.5 mm All Variants Color Max. cable diameter Max. wire size Order Number black 8 (10) mm 3 x 1 mm² / 3 x 14 AWG 4772.0110 █ black 10 mm 3 x 1 mm² / 3 x 14 AWG 4772.0210 █ █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock- Check-SCHURTER Max. torque for screws: Terminals: 0.8 Nm, Cable clamps: 0.8 Nm, Cover: 0.8 Nm
Cord Connectors (rewireable) 4772https://www.schurter.com /PG07b Connectors Packaging unit 50 Pcs Mating Inlets/Plugs Category / Description Appliance Inlet Overview complete 6100-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-3 6100-4, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-4 6102-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18 6102-3 6102-5, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18 6102-5 G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder 6150 Appliance Inlet further types to 4772 ... Distribution Unit Overview complete Distribution Unit for Snap-in Mounting with 1 IEC Appliance Inlet C14 and 1 Appliance Outlet F 0712 Distribution Unit with 1 IEC Appliance Inlet C14 and 2 Appliance Outlets F, Shuttered 4741 Distribution Unit with 1 IEC Appliance Inlet C14 and 4 Appliance Outlets F 4747 Distribution Unit with 1 IEC Appliance Inlet C14 or Power Cord, 4, 5 or 6 IEC Appliance Outlets F and Extra Components 4740 EMC Power Strip with Line Filter FLBB Distribution Unit further types to 4772 IEC Inlet Filter Overview complete GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14, Suitable for appliances with protection class I GRF2 5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I 5110 KFS, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, pre- wired KFS IEC Inlet Filter further types to 4772 Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Straight 9009 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 Plug further types to 4772 ... Power Entry Module Overview complete DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appli- ances with protection class I DD11 DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuse holder: 1 or 2 pole DD21 DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II DC11 KEB1, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, red, 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB1 KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB2 Power Entry Module further types to 4772 ...
Cord Connectors (rewireable)4772 https://www.schurter.com /PG07b Connectors Category / Description Power Entry Module with line filter Overview complete DD14, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuse holder:1 or 2 pole, 10 A, Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired DD14 KFB1, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appli- ance Inlet: IEC C14, prewired KFB1 KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch: 2-pole, Appliance Inlet: IEC C14, prewired KFB2 DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired DC12 DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch: 1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I DC22 Power Entry Module with line filter further types to 4772 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 09.03.2018