Power entry modules without line filter 4719https://www.schurter.com /PG05 Connectors IEC Appliance Outlet F Shuttered with Fuseholder 1-pole Snap-in version with neon indicator See below: Approvals and Compliances F 70° C

Description

  • Panel mount : Snap-in version from front side - 3 Functions : Connector shuttered Protection class I , Fuseholder for fuse-links 5 x 20 mm 1-pole , with or without neon indicator - Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. - Solder terminals 3.8 x 0.8 mm Characteristics - With internal connections, except neon indicator to allow for different configurations - Neon indicator with wire terminals (80...250V) - With slotted screw type fuseholder - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - For protection class II Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 10 A / 250 VAC; 50 Hz Ratings UL/CSA 10 A / 250 VAC; 60 Hz Dielectric Strength > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- rature -25 °C to 70 °C IP-Protection from front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I acc. to IEC 61140 Terminal Solder terminals 3.8 x 0.8 mm except neon indicator Panel Thickness S Snap-in: 1/1.2/1.5/2/2.5/3 mm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet F acc. to IEC 60320-3 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 1.6 W (1 pole) Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 4719 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40030183 UL Approvals UL UL File Number: E93617 Product standards Product standards that are referenced

Power entry modules without line filter4719 https://www.schurter.com /PG05 Connectors Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60320-3 Appliance couplers for household and similar general purposes Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the en- hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. White paperGlow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Dimensions [mm] 40.0 36.0 2.5 36.2 33.20 33.00 S 37.20 37.00max. R1.0

Power entry modules without line filter 4719https://www.schurter.com /PG05 Connectors Shutter operation: shutters opened by plug insertion Shutter operation: shutters closed when plug is removed Diagrams NEL NL Version without neon indicator NEL NL Version with neon indicator Derating Curves 1-pole Admissible power acceptance in Watt 02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C All Variants Panel Thickness s [mm] Neon indication Order Number 1 l 4719.3300 1.2 l 4719.8300 1.5 l 4719.4300 2 l 4719.5300 2.5 l 4719.6300 3 l 4719.7300 1 4719.3310 1.2 4719.8310 1.5 4719.4310 2 4719.5310 █ 2.5 4719.6310 3 4719.7310 █ Most Popular.

Power entry modules without line filter4719 https://www.schurter.com /PG05 Connectors Panel Thickness s [mm] Neon indication Order Number Availability for all products can be searched real-time:https://www. schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 100 Pcs Accessories Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0075 Mating Inlets/Plugs Category / Description Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Straight 9009 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 Plug further types to 4719 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 11.09.2018