Strain Gage Miniature Load Cell for Compression Forces, 0,1 ... 200 kN 4577A_000-674e-09.18 Force This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2009 ... 2018, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. Type 4577A... A high value/performance ratio and robust design characterize the compressive force miniature load cell Type 4577A... even in the high measuring ranges.
- Small size
- For static and dynamic measurements
- Stainless steel construction
- Standardized output signal 1 mV/V
Description
Force sensor Type 4577A... is designed as a flat, circular disc. The measuring element inside the body carries a strain gage full bridge which outputs a voltage directly proportional to the measurement variable on the application of a force. The load application knob for receiving compression forces is an integral part of the sensor. The measurement force must be applied centrically and without any transverse vectors. Ensure that the sensor Type 4577A... is mounted on a smooth and even surface. Application Their small dimensions enable load cells Type 4577A... to be used for measuring static and dynamic forces in restricted spaces. Force sensors of this type have a hermetically sealed body, allowing it to be used under dirty and corrosive industrial con- ditions. Applications include:
- Press-fit operations
- Draw-pull forces
- Spring power measurements
- Measurements of cutting forces
- Force measurements on mounting devices
- Functional tests Measurement direction compression Measuring ranges kN 0 ... 0,1 up to 0 ... 200 Limiting force % 150 Dynamic load % 50 (recommended) 70 (maximum) Operating temperature range °C –20 ... 100 Rated temperature range °C 15 ... 70 Temperature influence On zero %FSO/K ≤±0,02 On span %FSO/K ≤±0,03 Weight kg ≈0,04 ... 1,2 Material stainless steel 1.4542 Degree of protection (sensor body) IP64 (acc. to IEC/EN 60529) Bridge resistance: strain gage full bridge circuit Measuring range 0,1 ... 2, 200 kN Ω 350 nominal* Measuring range 5 ... 100 kN Ω 700 nominal* Accuracy: Measuring ranges up to 1 kN %FSO ≤±0,25 Measuring ranges of 2 kN %FSO ≤±0,5 (combined value for non-linearity hysteresis and repeatability) Supply voltage: Recommended VDC 5 Maximum VDC 10 Sensitivity: Measuring ranges up to 1 kN mV/V 1 ±0,25 % Measuring ranges of 2 kN mV/V 1 ±0,5 % * Deviations may occur. Technical Data
4577A_000-674e-09.18 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2009 ... 2018, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. Dimensions Meas. Range [kN] Dimensions [mm] Weight [kg] Natural frequen- cy [kHz]øD1 øD2 øD3 øD4 øD5 H1 H2 øT øA øB øC K L M N G 0 ... 0,1 31,8 29,4 20,6 8,1 19 9,9 8,1 25,5 – 3 2 – 40 2,5 3 M2,5 0,07 >2 0 ... 0,2 31,8 29,4 20,6 8,1 19 9,9 8,1 25,5 – 3 2 – 40 2,5 3 M2,5 0,07 >3 0 ... 0,5 31,8 29,4 20,6 8,1 19 9,9 8,1 25,5 – 3 2 – 40 2,5 3 M2,5 0,07 >5 0 ... 1 31,8 29,4 20,6 8,1 19 9,9 8,1 25,5 – 3 2 – 40 2,5 3 M2,5 0,07 >8 0 ... 2 31,8 29,4 20,6 8,1 19 9,9 8,1 25,5 – 3 2 – 40 2,5 3 M2,5 0,07 >11 0 ... 5 31,2 28,7 21,1 8,1 19,5 9,9 8,1 25,5 7 4,8 3 10,4 30,7 3,8 3 M2,5 0,11 >17 0 ... 10 31,2 28,7 21,1 8,1 19,5 9,9 8,1 25,5 7 4,8 3 10,4 30,7 3,8 3 M2,5 0,11 >25 0 ... 20 37,6 35 27,4 10,7 25,7 16 14 31,5 7 4,8 3 10,4 30,7 3,8 3 M2,5 0,17 >25 0 ... 50 37,6 35 27,4 10,7 25,7 16 14 31,5 7 4,8 3 10,4 30,7 3,8 3 M2,5 0,17 >40 0 ... 100 50,3 47 34,8 15,2 34,7 25,4 22,4 42 7 4,8 3 10,4 30 4,8 6 M4 0,35 >40 0 ... 200 76,2 74 46 20 45 38,1 33,5 60 7 4,5 3 11 45 6 6 M4 1,2 >40 G 3x120° G N øB øA øC M L K øD1 øD2 øT øD3 øD5 øD4 H2 Assembly requirements for support area: Height ≈sensor height Hardness HRC 60 Evenness µm <5 Parallelism µm <30 Optional Accessories Type
- Connection cable, 5 m, 6 pin/6 pin KSM071860-5
- Connection cable, 5 m, 6 pin/open ends KSM103820-5 Measuring range [kN] 0,1 0,1 0,2 0,2 0,5 0,5 1 1 2 2 5 5 10 10 20 20 50 50 100 100 200 200 Connector Plug 6 pin M16 circular connector 9 pin D-Sub connector Ordering Key Type 4577A Included Accessories
- None Electrical Connection C3 approx. 2 m shielded, highly flexible cable, 9 pin D-Sub connector Electrical Connection C1 approx. 2 m shielded, highly flexible cable, 6 pin M16 circular connector 2Signal + Signal – Sense – Supply – Supply + Sense + Signal + Signal – Supply – Supply + Advice for connector plug C1 and C3 C1 connector is applicable for DMF-P family C3 connector is applicable for maXYmos family