Thermal (T- and TA-Line) TA45-2RUwww.schurter.com /PG17_20 Circuit Breakers Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation, with undervoltage

Description

  • Thermal circuit breaker - 1 or 2 pole thermal overload protection - Positively trip-free release - High configurability - Rocker non-illuminated or illuminated - Snap-in version - Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2) Approvals - Approval Reference Type: TA45 - IEC Standard: IEC 60934 - UL Standard: UL 1077 - CSA Standard: CSA C22.2 No. 235 - GB Standard: GB 17701

Applications

  • Power tools - Industrial appliances - Power supplies Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor- Stock-Check, Detailed request for product, Product News Technical Data Rated Voltage AC 240 V Rated Voltage DC 60 V Rated current range AC 0.05 - 20 A Conditional short circuit ca- pacity IEC: Inc, PC1, AC 240 V: 1 kA Degree of Protection from front side IP 40 acc. to IEC 60529 Dielectric Strength 4 kVAC Insulation resistance 500 VDC > 100 MΩ Endurance typical mechanical: 50'000 switching cycles ␣ AC: 1 x Ir: 50'000 switching cycles ␣ DC: 1 x Ir: 50'000 switching cycles Overload AC: min. 40 trips @ 6 x Ir ␣ DC: min. 40 trips @ 4 x Ir Ambient temperature -10 °C to 55 °C Vibration Resistance ± 0.75 mm @ 5 - 60 Hz acc. to IEC 60068-2-6, test Fc

10 G @ 60 - 500 Hz

acc. to IEC 60068-2-6, test Fc Shock Resistance 30 G / 18 ms acc. to IEC 60068-2-27, test Ea Possible Tripping Types Thermal Undervoltage release Remote trip Mechanical lock-out latch Actuation type Rocker Weight 50 - 60 g

Thermal (T- and TA-Line)TA45-2RU www.schurter.com /PG17_20 Circuit Breakers Dimension Undervoltage release, remote trip release 3410.6 15.5 21.5 5.3 26.7 8.4 23.7 44.1 aP1 3 5 12.5 3.5 7.2 1.5 6.3 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm B) Quick connect terminal, IEC 61210, A2.8-0.8 mm Mechanical lock-out latch 5.3 22.8 26.7 8.4 23.7 44.1 aP1 3 5 12.5 3.5 50.6 10.6 10.8 17.5 19.5 (4.5)3 .5 2.8 5.5 (4.5)3 .5 2.5 * A) Quick connect terminal, IEC 61210, A6.3-0.8 mm *) max. switching stroke

Thermal (T- and TA-Line) TA45-2RUwww.schurter.com /PG17_20 Circuit Breakers Accessories / factory mounted AZM01 / Collar with cover, IP54 8.1 12.5 56.6 50.5 17.6 33.6 19.2 27.5 43.7 AZM02 / Raised collar with cover, narrow, IP54 AZM03 / Raised collar, IP40 15.3 56.5 50.5 17.6 33.6 19.2 27.5 43.7 AZM10 / Collar with cover, narrow, IP54 19.2 8.8 37.2 17.3 43.8 AZM11 / Partially raised collar with cover, narrow, IP54 AZM12 / Partially raised collar without cover, narrow, IP40 17.3 43.8 AZM13 / Raised collar narrow, IP40 50 27 33.210.6 AZM14 / Raised collar with cover narrow, IP54 17.3 33.210.6 19.2

Thermal (T- and TA-Line)TA45-2RU www.schurter.com /PG17_20 Circuit Breakers Cut-out and pin-out Cut-out snap-in type b a (1.0 – 5.0) a b 1.0 44,5...45,0 1.5 44,5...45,0 2.0 44,7...45,2 2.5 44,7...45,2 3.0 44,8...45,3 4.0 44,9...45,4 5.0 45,0...45,5 21.7 +0.2 –0.0 1) Assemble 2) edge must be sharp Pin-out b a c U-Relais

Thermal (T- and TA-Line) TA45-2RUwww.schurter.com /PG17_20 Circuit Breakers Diagrams Without thermal overload protection P2 P1 6 5 1 pole thermal overload protection P2 P1 1 pole thermal overload protection, Shunt terminal P2 P1 6 5 2 pole thermal overload protection 4 3 P2 P1 2 pole thermal overload protection, Shunt terminal P2 P1 4 3 Undervoltage release P2 P1 Undervoltage release with additional contact P2 P1b Undervoltage release with 2 additional contacts P2 P1b a Remote trip release P2 P1c Mechanical lock-out latch P2 P1

Thermal (T- and TA-Line)TA45-2RU www.schurter.com /PG17_20 Circuit Breakers Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated cur- rent for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient temperature [°C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor = 1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A Undervoltage release Max. operating voltage 1.1 Ue Rated operating voltage Ue 5 V 12 V 24 V 48 V 120 V 240 V 400 V 1) Highest reset level 0.85 Ue Lowest trip level 0.20 Ue Trip delay 20 ms - 50 ms Impulse withstand voltage (1.2 / 50 µs) ≥4 kV 1) only for 3pole Remote trip Permissible impuls duration of the make contact (no) Between terminal C and P1 unlimited Electrical load of the make contact (no) Current max. 12 mA / power max. 1.1 W Time-Current-CurvesTime in Seconds Type TA45 Rated current In <3 A 1 pole protected 2 pole protected Ambient temp. +23ºC 10'000 2\000 1\000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 10854321,32 Multiple of Rated Current In Reference Temperature +23° Time in Seconds 0,5 0,3 0,2 0,1 10'000 2\000 1\000 500 200 100 [ sec ][ min ] 1,05 10854321,32 Type TA45 Rated current 3 A > In <18 A 1 pole protected 2 pole protected Ambient temp. +23ºC Multiple of Rated Current In Reference Temperature +23°

Thermal (T- and TA-Line) TA45-2RUwww.schurter.com /PG17_20 Circuit Breakers Time in Seconds 0,5 0,3 0,2 0,1 10'000 2\000 1\000 500 200 100 [ sec ][ min ] 1,05 10854321,32 Type TA45 Rated current In > 18 A 1 pole protected 2 pole protected Ambient temp. +23ºC Multiple of Rated Current In Reference Temperature +23° Config. Code The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function Basic function Configuration key 2-pole, rocker, flat connection, illuminated 220 V...240 V A02 2-pole, rocker, flat connection, illuminated 110 V...120 V A04 2-pole, rocker, flat connection, illuminated 220 V...26 V A07 2-pole, rocker, flat connection, illuminated 10 V...13 V A08 2-pole, rocker, flat connection, illuminated 4 V...7 V A09 2-pole, rocker, 1pole overload protection, flat connection, illuminated 220 V...240 V A12 2-pole, rocker, 1pole overload protection, flat connection, illuminated 110 V...120 V A14 2-pole, rocker, 1pole overload protection, flat connection, illuminated 20 V...26 V A17 2-pole, rocker, 1pole overload protection, flat connection, illuminated 10 V...13 V A18 2-pole, rocker, 1pole overload protection, flat connection, illuminated 4 V...7 V A19 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, illuminated 220 V...240 V A22 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, illuminated 110 V...120 V A24 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, illuminated 20 V...26 V A27 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, illuminated 10 V...13 V A28 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, illuminated 4 V...7 V A29 2-pole, rocker, 2pole overload protection, flat connection, illuminated 220 V...240 V A32 Basic function Configuration key 2-pole, rocker, 2pole overload protection, flat connection, illuminated 110 V...120 V A34 2-pole, rocker, 2pole overload protection, flat connection, illuminated 20 V...26 V A37 2-pole, rocker, 2pole overload protection, flat connection, illuminated 10 V...13 V A38 2-pole, rocker, 2pole overload protection, flat connection, illuminated 4 V...7 V A39 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, illuminated 220 V...240 V A42 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, illuminated 110 V...120 V A44 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, illuminated 20 V...26 V A47 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, illuminated 10 V...13 V A48 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, illuminated 4 V...7 V A49 2-pole, rocker, screw connection, illuminated 220 V...240 V A52 2-pole, rocker, screw connection, illuminated 110 V...120 V A54 2-pole, rocker, screw connection, illuminated 20 V...26 V A57 2-pole, rocker, screw connection, illuminated 10 V...13 V A58 2-pole, rocker, screw connection, illuminated 4 V...7 V A59 2-pole, rocker, 1pole overload protection, screw connection, illuminated 220 V...240 V A62 2-pole, rocker, 1pole overload protection, screw connection, illuminated 110 V...120 V A64 2-pole, rocker, 1pole overload protection, screw connection, illuminated 20 V...26 V A67

Thermal (T- and TA-Line)TA45-2RU www.schurter.com /PG17_20 Circuit Breakers Basic function Configuration key 2-pole, rocker, 1pole overload protection, screw connection, illuminated 10 V...13 V A68 2-pole, rocker, 1pole overload protection, screw connection, illuminated 4 V...7 V A69 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 220 V...240 V A72 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 110 V...120 V A74 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 20 V...26 V A77 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 10 V...13 V A78 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, illuminated 4 V...7 V A79 2-pole, rocker, 2pole overload protection, screw connection, illuminated 220 V...240 V A82 2-pole, rocker, 2pole overload protection, screw connection, illuminated 110 V...120 V A84 2-pole, rocker, 2pole overload protection, screw connection, illuminated 20 V...26 V A87 2-pole, rocker, 2pole overload protection, screw connection, illuminated 10 V...13 V A88 2-pole, rocker, 2pole overload protection, screw connection, illuminated 4 V...7 V A89 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 220 V...240 V A92 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 110 V...120 V A94 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 20 V...26 V A97 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 10 V...13 V A98 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, illuminated 4 V...7 V A99 2-pole, rocker, flat connection, without illumination ABC 2-pole, rocker, 2pole overload protection, flat connection, without illumi- nation ABD 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, without illumination ABF 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, without illumination ABG 2-pole, rocker, 1pole overload protection, flat connection, without illumi- nation ABT 2-pole, rocker, flat connection, momentary switch, without illumination AEC 2-pole, rocker, 2pole overload protection, flat connection, momentary switch, without illumination AED 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, momentary switch, without illumination AEF 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, momentary switch, without illumination AEG 2-pole, rocker, 1pole overload protection, flat connection, momentary switch, without illumination AET 2-pole, rocker, screw connection, without illumination AHC 2-pole, rocker, 2pole overload protection, screw connection, without illu- mination AHD 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, without illumination AHF 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, without illumination AHG 2-pole, rocker, 1pole overload protection, screw connection, without illu- mination AHT 2-pole, rocker, screw connection, momentary switch, without illumination AJC 2-pole, rocker, 2pole overload protection, screw connection, momentary switch, without illumination AJD 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, momentary switch, without illumination AJF Basic function Configuration key 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, momentary switch, without illumination AJG 2-pole, rocker, 1pole overload protection, screw connection, momentary switch, without illumination AJT TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour Actuator colour Configuration key Clear transparent 1 Red transparent 3 Green transparent 4 Orange transparent 6 Black B Green G Red R White W Orange X Yellow Y TA45 Legend Configuration key embossed I F white printed ON OFF H black printed ON OFF K white printed I L black printed I M white printed I0 P black printed I0 R white printed OFF ON I S black printed OFF ON I T TA45 Rated current Configuration key without thermal overload protection / temporarily without VDE approval C00

0.05 A Z05

0.1 A J01

0.2 A J02

Other rated currents on request

Thermal (T- and TA-Line) TA45-2RUwww.schurter.com /PG17_20 Circuit Breakers Rated current Configuration key

0.3 A J03

0.4 A J04

0.5 A J05

0.6 A J06

0.7 A J07

0.8 A J08

0.9 A J09

1.0 A J10

1.1 A J11

1.2 A J12

1.3 A J13

1.4 A J14

1.5 A J15

1.6 A J16

1.7 A J17

1.8 A J18

1.9 A J19

2.0 A J20

2.1 A J21

2.2 A J22

2.3 A J23

2.5 A J25

2.8 A J28

3.0 A 030

3.5 A 035

4.0 A 040

4.5 A 045

5.0 A 050

6.0 A 060

6.5 A 065

7.0 A 070

7.5 A 075

8.0 A 080

9.0 A 090

10.0 A 100

11.0 A 110

12.0 A 120

13.0 A 130

14.0 A 140

15.0 A 150

16.0 A 160

17.0 A 170

18.0 A 180

19.0 A 190

20.0 A 200

Other rated currents on request TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch Release / lock-out latch Configuration key Remote trip release, rated voltage 240 V AC A2 Remote trip release, rated voltage 230 V AC A3 Remote trip release, rated voltage 120 V AC A4 Remote trip release, rated voltage 48 V AC / DC A6 Remote trip release, rated voltage 24 V AC / DC A7 Remote trip release, rated voltage 12 V AC / DC A8 whithout release / lock-out latch C0 Undervoltage release with additional contact, rated voltage 240 V AC E2 Undervoltage release with additional contact, rated voltage 230 V AC E3 Undervoltage release with additional contact, rated voltage 120 V AC E4 Undervoltage release with additional contact, rated voltage 48 V AC / DC E6 Undervoltage release with additional contact, rated voltage 24 V AC / DC E7 Undervoltage release with additional contact, rated voltage 12 V AC / DC E8 Undervoltage release with additional contact, rated voltage 5 V AC / DC E9 Mechanical lock-out latch S0 Undervoltage release, rated voltage 240 V AC U2 Undervoltage release, rated voltage 230 V AC U3 Undervoltage release, rated voltage 120 V AC U4 Undervoltage release, rated voltage 48 V AC / DC U6 Undervoltage release, rated voltage 24 V AC / DC U7 Undervoltage release, rated voltage 12 V AC / DC U8 Undervoltage release, rated voltage 5 V AC / DC U9 Undervoltage release with 2 additional contacts, rated voltage 240 V AC Z2 Undervoltage release with 2 additional contacts, rated voltage 230 V AC Z3 Undervoltage release with 2 additional contacts, rated voltage 120 V AC Z4 Undervoltage release with 2 additional contacts, rated voltage 48 V AC / DC Z6 Undervoltage release with 2 additional contacts, rated voltage 24 V AC / DC Z7 Undervoltage release with 2 additional contacts, rated voltage 12 V AC / DC Z8 Undervoltage release with 2 additional contacts, rated voltage 5 V AC / DC Z9 TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories Factory mounted accessories Configuration key Without cover Collar with cover, IP54 AZM01 Raised collar with cover, IP54 AZM02 Raised collar, IP40 AZM03 Raised collar with cover narrow, IP54 AZM10 Partially raised collar with cover, narrow, IP54 AZM11 Partially raised collarwithout cover, narrow, IP40 AZM12 Raised collar narrow, IP40 AZM13 Raised collar with cover narrow, IP54 AZM14 For subsequent fitting accessories see: http://www.schurter.ch/pdf/english/typ_TA45-ACC.pdf

Thermal (T- and TA-Line)TA45-2RU www.schurter.com /PG17_20 Circuit Breakers Variants Thermal overload pro- tection Addition connection type Illumination Actuator colour Legend Rated current Accessories Config. Code Order Number 2-pole Quick connect terminal without illu- mination White black printed 5.0 A Without cover TA45-ABDWK050U3 4430.1564 2-pole Quick connect terminal illumination 220 V...240 V Orange trans- parent white printed 4.0 A Collar with cover, IP54 TA45-A326L040U2-AZM01 4430.2609 Quick connect terminal without illu- mination White embossed without thermal overload protec- tion / temporarily without VDE approval Raised collar, IP40 TA45-ABCWFC00U4-AZM03 4430.2781 1-pole Quick connect terminal without illu- mination Yellow black printed 8.0 A Raised collar with cover nar- row, IP54 TA45-ABTYK080E3-AZM10 4430.2960 1-pole Quick connect terminal without illu- mination Orange black printed 8.0 A Without cover TA45-ABTXM080E2 4430.3240 █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER Packaging Unit 1 Pcs Accessories The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 13.10.2016