for tab connections 6,3 mm 03.19WECO | www.wecogroup.com 108 7,5 L ø3,2 Flat plug guides 440-PA are used for insulating flat plug connections of nominal size 6,3. During assembly, a latch locks the flat plug into place in the housing. The tab receptacle can then be plugged onto the plug. All along the plug guide, the plug contact is completely insulated. Part Numbers No. of poles 440-PA Length A * PU 1 20.830.011 10,00 15 000 2 20.830.012 22,00 1000 3 20.830.013 34,00 12,00 500 4 20.830.014 46,00 24,00 500 5 20.830.015 58,00 36,00 100 6 20.830.016 70,00 48,00 100 7 20.830.017 82,00 60,00 100 8 20.830.018 94,00 72,00 100 9 20.830.019 106,00 84,00 100 10 20.830.020 118,00 96,00 70 11 20.830.021 130,00 108,00 60 12 20.830.022 142,00 120,00 60 * = Distance of the two outermost mounting holes General Information Pitch 12 mm No. of poles 1 - 12 Technical Data Clamping Range solid / flexible / AWG 6,0 mm² / 10 AWG Overvoltage Category III Pollution Severity Level 2 Rated Voltage 630 V Rated Impulse Voltage 6 kV Rated Current 20 A: with receptacle 6,3; wire 6,0 mm² (10 AWG) Material Moulding PA, natural, V-2 Comparative Tracking Index CTI ≥ 600 Insulating Group I Temperature Range -40°C up to 100°C