Power Entry Modules with Line Filter FKID www.schurter.com/pg06 EMC Products IEC Appliance Inlet C14 with Filter 2-Stage, Fuseholder 2-pole, Line Switch 2-pole Standard- or Medical-Filter C14 70° C

Description

  • Panel Mount: Screw-on mounting from front side - 4 Functions: Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm 2-pole, Line Switch 2-pole, Line filter in standard and medical ver- sion, 2 positions - Quick connect terminals 6.3 x 0.8 mm Approvals - VDE License Number: 40004665 - UL License Number: E72928 Characteristics - Compact design with optimal shielding - All single elements are already wired - Plug removal necessary for fuse-link replacement If the power entry module is installed as normal, it is not possible to touch any live parts with the test-finger according to IEC60529 Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - 2-stage line filter with increased attenuation With EMC-shield - Qualified for use in equipment according IEC/EN 60950 Other versions on request - Medical version M80 References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories T echnical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz Leakage Current standard < 0.25 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness s Screw: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Fuseholder 2-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 1.6 W (2-pole) Power Acceptance @ Ta > 23°C Admissible power acceptance at hig- her ambient temperature see derating curves Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 1'200'000 h acc. to MIL-HB-217 F

Power Entry Modules with Line FilterFKID www.schurter.com/pg06 EMC Products Dimensions 67 mm Case 45 recommend for new designs 40 49.5 40 6.3x0.8 ±0.5 ±0.5 R3 61.5 50±0.550 67 28.7±0.5 ±0.55.5 14 29.5 3.5 ø 3.2 ø 5.8x90° 60.2 ±0.15 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacity Cy [nF] Capacity Cy [nF] R [MΩ] 1 Standard Version 2 x 10 68 1.5 1 1 2 Standard Version 2 x 4 68 1.5 1 1 4 Standard Version 2 x 1.5 68 1.5 1 1 6 Standard Version 2 x 0.8 68 1.5 1 1 10 Standard Version 2 x 0.3 68 1.5 1 1

1 Medical Version (M5) 2 x 10 68 - - 1

2 Medical Version (M5) 2 x 4 68 - - 1

4 Medical Version (M5) 2 x 1.5 68 - - 1 6 Medical Version (M5) 2 x 0.8 68 - - 1 10 Medical Version (M5) 2 x 0.3 68 - - 1 Diagrams Standard version 1) Line 2) only FKID 3) Load Medical version N PE L Cx PE’ R Cx 1) 2) 1) Line 2) Load Derating Curves 2-poleAdmissible power ac- ceptance in Watt per pole0 2 0 4 0 6 0 8 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C

Power Entry Modules with Line Filter FKID www.schurter.com/pg06 EMC Products Attenuation Loss - - - - differential mode _____ common mode Standard version 1 A 2 A 4 A 6 A 10 A Medical version (M5) 1 A 2 A 4 A 6 A 10 A Variants Socket and fuse drawer included Type Rated Current [A] Filter-Type Fuseholder Line Switch Housing Material: Housing Comment Order Number FKID 1 Standard Version 2-pole 2-pole 45 Aluminum - 4304.5061 FKID 2 Standard Version 2-pole 2-pole 45 Aluminum - 4304.5062 FKID 4 Standard Version 2-pole 2-pole 45 Aluminum - 4304.5063 FKID 6 Standard Version 2-pole 2-pole 45 Aluminum - 4304.5064 FKID 10 Standard Version 2-pole 2-pole 45 Aluminum - 4304.5065 FKID 1 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.5081 FKID 2 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.5082 FKID 4 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.5083 FKID 6 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.5084 FKID 10 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.5085 FKID 1 Standard Version 2-pole 2-pole 45 Nickel plated steel 1) 4304.5021 FKID 2 Standard Version 2-pole 2-pole 45 Nickel plated steel 1) 4304.5022 FKID 4 Standard Version 2-pole 2-pole 45 Nickel plated steel 1) 4304.5023 FKID 6 Standard Version 2-pole 2-pole 45 Nickel plated steel 1) 4304.5024 FKID 10 Standard Version 2-pole 2-pole 45 Nickel plated steel 1) 4304.5025 FKID 2 Medical Version (M5) 2-pole 2-pole 45 Nickel plated steel 1) 4304.5067 1) Versions with nickel plated steel enclosure are on phase-out. For new designs we recommend the versions with aluminum enclosure.

Power Entry Modules with Line FilterFKID www.schurter.com/pg06 EMC Products Packaging unit 10 Pcs Accessories 0859.0074 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to FKID Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to FKID ... Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to FKID ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.