FKH_V01 SCHURTER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Power Entry Modules with Line Filter FKHhttps://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole, Line Switch 2-pole Screw-on mounting from front side Aluminum Screw-on mounting from front side Nickel plated steel See below: Approvals and Compliances C14 70° C

Description

  • Panel mount : Screw-on mounting front side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1-pole , Line-filter in standard version - Quick connect terminals 6.3 x 0.8 mm Characteristics - Compact design with optimal shielding - All single elements are already wired - Plug removal necessary for fuse-link replacement - With EMC-shield - Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP , 1 MOPP) For applications according IEC/UL 62368-1 we recommend variants with bleed resistor Other versions on request - Medical Version (M80) References Alternative: version with 2-stage filter FKHD We recommend for new applications the type DD12 Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.25 mA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection front side IP40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 1.6 W (1 pole) Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Line Switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Line Filter Standard version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 1'700'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER.

Power Entry Modules with Line FilterFKH https://www.schurter.com /PG06 EMC Products Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FKH Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40004665 UL Approvals UL UL File Number: E72928 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. White Paper Glow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP , 1 MOPP)

Power Entry Modules with Line Filter FKHhttps://www.schurter.com /PG06 EMC Products Dimension [mm] Case 45 40 49 40 6.3x0.8 ±0.5 +0.5 –0.2 R4 61.3 50±0.550 67 28.7±0.5 ±0.55.5 14 29.5 3.5 ø 3.2 ø 6.3x90° 60.4 ±0.15 Case 50 40 49.5 40 6.3x0.8 ±0.5 R4 40.5 50±0.550 55 28.7±0.5 ±0.55.5 15 29.5 3.5 ø 3.2 ø 6.3x90° 60.4 ±0.15 +0.5 –0.261 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard version 2 x 10 68 2.2 1 2 Standard version 2 x 4 68 2.2 1 4 Standard version 2 x 1.5 68 2.2 1 6 Standard version 2 x 0.8 68 2.2 1 10 Standard version 2 x 0.3 68 2.2 1

1 Medical Version (M5) 2 x 10 68 - 1

2 Medical Version (M5) 2 x 4 68 - 1

4 Medical Version (M5) 2 x 1.5 68 - 1 6 Medical Version (M5) 2 x 0.8 68 - 1 10 Medical Version (M5) 2 x 0.3 68 - 1

Power Entry Modules with Line FilterFKH https://www.schurter.com /PG06 EMC Products Diagrams Standard version N PE L Cx PE’ R Cx Cy Cy 1) 2) R = 1MΩ 1) Line 2) Load Medical Version (M5) N PE L Cx PE’ R Cx 1) 2) 1) Line 2) Load Derating Curves 1-pole Admissible power acceptance in Watt02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1 A 2 A 4 A 6 A 10 A

Power Entry Modules with Line Filter FKHhttps://www.schurter.com /PG06 EMC Products Medical version (M5) 1 A 2 A 4 A 6 A 10 A All Variants Type Rated Current [A] Filter-Type Fuseholder Line Switch Housing Material: Housing Order Number FKH 1 Standard version 1-pole 2-pole 45 Aluminum 4304.4041 FKH 2 Standard version 1-pole 2-pole 45 Aluminum 4304.4042 FKH 4 Standard version 1-pole 2-pole 45 Aluminum 4304.4043 FKH 6 Standard version 1-pole 2-pole 45 Aluminum 4304.4044 FKH 10 Standard version 1-pole 2-pole 45 Aluminum 4304.4045 FKH 1 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4046 FKH 2 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4047 FKH 4 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4048 FKH 6 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4049 FKH 10 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4050 FKH 1 Standard version 1-pole 2-pole 50 Nickel plated steel 4304.4001 █ FKH 2 Standard version 1-pole 2-pole 50 Nickel plated steel 4304.4002 FKH 4 Standard version 1-pole 2-pole 50 Nickel plated steel 4304.4003 █ FKH 6 Standard version 1-pole 2-pole 50 Nickel plated steel 4304.4004 █ FKH 10 Standard version 1-pole 2-pole 50 Nickel plated steel 4304.4005 █ █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs

Power Entry Modules with Line FilterFKH https://www.schurter.com /PG06 EMC Products Accessories 0859.0074 RC320 Rear Cover for Power Entry Module Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with pro- tection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Connector Overview complete

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06

4781 Mounting: Power Cord, Cable, Connector: IEC C15 4781

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15 4784

... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 04.01.2022