Power Entry Modules with Line Filter KFB2 www.schurter.com/pg06 EMC Products IEC Appliance Inlet C14 with Filter, Line Switch 2-pole Standard- or Medical-Filter C14 70° C

Description

  • Panel Mount: Screw-on mounting from front side - 3 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Line filter in stan- dard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter KEB2 - We recommend for new applications the new type DC12 Approvals - VDE License Number: 40004665 (FKT) - UL License Number: E72928 (FKT) Characteristics - All single elements are already wired - Line switch non-illuminated - With EMC-shield - Qualified for use in equipment according IEC/EN 60950 References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories T echnical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness s Screw: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 1'900'000 h acc. to MIL-HB-217 F

Power Entry Modules with Line FilterKFB2 www.schurter.com/pg06 EMC Products Dimensions 60.5 mm 41.7 30.5 6.3x0.8 R 4.5 R 6 R 3.1 +0.3 ±0.15 57.5 5 63 max. 27.2 ø 3.3 ø 6.5x90° 28.5 +0.3 R 3 M3/ø 3.6 42.5x 28.2 ±0.5 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 68 2.2 - 2 Standard Version 2 x 4 68 2.2 - 4 Standard Version 2 x 1.5 68 2.2 - 6 Standard Version 2 x 0.8 68 2.2 - 10 Standard Version 2 x 0.3 68 2.2 -

1 Medical Version (M5) 2 x 10 68 - 1

2 Medical Version (M5) 2 x 4 68 - 1

4 Medical Version (M5) 2 x 1.5 68 - 1 6 Medical Version (M5) 2 x 0.8 68 - 1 10 Medical Version (M5) 2 x 0.3 68 - 1 Diagrams Standard version 1) Line 2) Load Medical version 1) Line 2) Load

Power Entry Modules with Line Filter KFB2 www.schurter.com/pg06 EMC Products Attenuation Loss - - - - differential mode _____ common mode Standard version 1 A 2 A 4 A 6 A 10 A Medical version (M5) 1 A 2 A 4 A 6 A 10 A Variants Rated Current [A] Filter-Type Order Number 1 Standard Version 4302.5311 2 Standard Version 4302.5312 4 Standard Version 4302.5313 6 Standard Version 4302.5314 10 Standard Version 4302.5315 1 Medical Version (M5) 4302.5331 2 Medical Version (M5) 4302.5333 4 Medical Version (M5) 4302.5335 6 Medical Version (M5) 4302.5337 10 Medical Version (M5) 4302.5339 Packaging unit 10 Pcs T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 68 2.2 - 2 Standard Version 2 x 4 68 2.2 - 4 Standard Version 2 x 1.5 68 2.2 - 6 Standard Version 2 x 0.8 68 2.2 - 10 Standard Version 2 x 0.3 68 2.2 - 4 Medical Version (M5) 2 x 1.5 68 - 1 6 Medical Version (M5) 2 x 0.8 68 - 1 10 Medical Version (M5) 2 x 0.3 68 - 1

Power Entry Modules with Line FilterKFB2 www.schurter.com/pg06 EMC Products Accessories 0859.0072 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to KFB2 Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to KFB2 ... Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to KFB2 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.