www.e-t-a.com Panelboard Power Distribution System XSVS Series Type No. XSVS Power Distribution System Type I UL67 & UL508 Interior Only EE UL67 & UL508 Enclosed Assembly - European IEC Style Breakers EU UL67 & UL508 Enclosed Assembly - US NEMA Style Breakers Ampacity 1 150 Amp 2 225 Amp Main Lug Incoming 6M Single Mechanical Lugs 3M Parallel Mechanical Lugs 3C Parallel Compression Lugs Configuration S Single Column D Double Column Bus Bar
2 A and B Phase
3 A, B and C Phase
12 Circuits
24 Circuits
36 Circuits
42 Circuits
72 Circuits
XSVS EU 2 6M S 2 42 C ordering example * 150A assembly single column 12, 24, 36 circuits only
Description
XSVS is a patented cULus listed panelboard with an architecture compatible with all Molded Case and Miniature Circuit breakers on the market. The system is touch safe and designed to insulate electrical components and isolate electrical arcs from service personnel. Power distribution applications where UL67 panelboards are required by the National Electrical Code (NEC). Including industrial facilities, data centers, manufacturing facilities, laboratories, heath care facilities, and warehouses. XSVS
Ordering Information
System Ampacity 150A & 225A Branch Circuit Ampacity 32A, 63A, 100A Voltage Rating 120, 240, 277, 480, 575, 600 VAC
24 VDC (UL 508 only)
Voltage Type Delta or Wye / 1ph or 3ph / 2, 3, or 4 wire Withstand 10kA (higher rating available upon request) Neutral 100% or 200% Assembly Configuration Enclosure UL Type 50 Interior Only Available as a single unit Main Incoming Main Lug or Main Breaker Single Cable #4-4/0 Compression Lug Single Cable #4-4/0 Crimp Lug Parallel Cable #8-1/0 Compression Lug Parallel Cable #8-1/0 Crimp Lug Branch Circuit Configurations Branch Circuits Single or Double Column Circuits 12, 24, 36, 42, 72UL Certification E493713 UL67, E474038 UL 508 & CSA22.2 IEC Certification IEC60529 IP20 Touchsafe Design Personnel have no exposure to energized components Certifications
www.e-t-a.com Panelboard Power Distribution System XSVS Series Panelboard Power Distribution System XSVS Series Interior Dimensions Enclosure Dimensions Single Column Assembly Single Column Assembly Double Column Assembly Double Column Assembly Circuit A B C D Circuit A B C 36 17.0” 64.5 6.0” Circuit A B C 36 24.0” 45.0 6.0” 42 24.0” 51.5 6.0” Circuit A B C D
www.e-t-a.com Panelboard Power Distribution System XSVS Series Panelboard Power Distribution System XSVS Series XSVS UL67 Assembly Breaker DIN Spacers Fills in-between breakers Branch Circuit Plug Fills spare circuit connection wells Spring Connector Plugs into bus allowing power to be pulled from the bus and connected to the breaker Spring Connector Joiner Allows single spring connectors to be joined together for 2 and 3 pole breakers Spring Connector Clamp Secures spring connector assembly to the interior The XSVS Power Distribution system is approved for applications where panelboards are required by the National Electrical Code (NEC) and NFPA 70. The assemblies comply with all certification requirements covering panelboards applied in control and protection of electrical lighting and appliance branch circuits, power circuits, and feeder distribution. Accessories XSVSSC32A 32A Breaker Spring Connector XSVSSCJ2P 2 Pole Spring Connector ClampXSVSSC63A 63A Breaker Spring Connector XSVSSCJ3P 3 Pole Spring Connector ClampXSVSSC100A 100A Breaker Spring Connector XSVSMIC Incoming Cover XSVSBCPLG Branch Circuit Plug XSVSDRSP DIN Rail Breaker Spacer XSVSESTP DIN Rail End Stop XSVSCLSP Incoming Crimp Lug Spacer XSVSSCC Spring Connector Clamp XSVSCCS Incoming Cable Clamp for Single Wire XSVSCCD Incoming Cable Clamp for Parallel Wires
www.e-t-a.com Thermal-Magnetic Miniature Circuit Breaker 4230-T... Single pole and multi-pole thermal-magnetic miniature circuit breakers (MCBs) in accordance with UL 489. A positively trip-free snap action mechanism ensures reliable switching behavior. Type No. 4230 single & multipole thermal-magnetic high performance circuit breaker Mounting T1 rail mounting Numbr of poles 1 single pole protected 2 double pole protected 3 three pole protected Accessories 0 without Terminals K0 screw terminals Characteristic curve B thermal 1.05 - 1.30* In; magnetic 3.2 - 4.8* In C thermal 1.05 - 1.30* In; magnetic 6.4 - 9.6* In D thermal 1.05 - 1.30* In; magnetic 9.6 - 14.4* In Approvals E EN 60947-2 (TÜV) / UL 1077 U UL 489 (only 1, 2 & 3 pole) Current Ratings 30, 32, 35, 40, 50, 60, 63 A 4230 - T1 - 1 0 - K0 C E - 10A ordering example Voltage rating and current rating range to UL 489 1-pole: AC 120 V; 1... 63 A 2, 3-pole: AC 240 V, 1... 63 A 1-pole: AC 277 V, 1... 63 A 2, 3-pole: AC 480 V, 1...32 A 1-pole: DC 60 V, 1... 63A 2, 3-pole: DC 125 V, 1... 63 A Endurance Mecahnically 20,000 cycles Electrically 6,000 cycles Time Current Characteristics