420E212 PROTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

DUAL 4-20mA CONTROL LOOP PROTECTOR 105053.R4 7/04 www.protekdevices.com 420E212 thru 420E260

APPLICATIONS

✔ Security Alarm Systems ✔ Industrial Control & Monitoring Systems ✔ Remote Tech Site Station ✔ Process Control Loops IEC COMPATIBILITY (EN61000-4) ✔ 61000-4-2 (ESD): Air - 15kV, Contact - 8kV ✔ 61000-4-5 (Surge): 8/20µs - 95A, Level 4 (Line-Gnd) & 48A, Level 4 (Line-Line)

FEATURES

✔ Designed for 4-20mA Current Loops ✔ Automatic Reset - Does Not Interrupt Service ✔ Permanent Two-Stage Line Pair Protection ✔ Common Mode & Differential Mode Protection ✔ Subnanosecond Response Time ✔ Effective Against Lightning, Inductive Switching and ESD MECHANICAL CHARACTERISTICS ✔ Weight: 50 grams (Approximate) ✔ Flammability Rating UL 94V-0 ✔ Device Marking: Logo, Terminal Designations, Date Code & Part Number

DESCRIPTION

The 420E2 series is a two stage transient voltage protector providing primary and secondary protection against lightning, inductive switching and electrostatic discharge (ESD) transient threats. The first stage diverts the transient current through the ground terminal return path and the second stage clamps the voltage to a safe level without interruption of service. The 420E2 series is designed to protect 4-20mA analog control loops from differential and common mode transients. Terminals 1 and 2 are designed as the line pairs for both the line and equipment side of the protector. A transient voltage suppressor is internally connected across each line pair for differential mode protection. Each line pair is referenced to ground. This product can also be used on telephone, signal/data lines, security timing and control interface circuits. 05053 420E

205053.R4 7/04 www.protekdevices.com DEVICE CHARACTERISTICS INSTALLATION INSTRUCTIONS There are two (2) terminals on the LINE SIDE and three (3) wires on the EQUIPMENT SIDE of this surge protection device (SPD). The Ground lead is considered ground for both the input terminal and the equipment wire connections. For the best results, the ground wire should be connected to a low impedance ground or the green wire AC power ground. It is recommended that a #14 standard wire be used for this connection. Field (current) loops or incoming signal/data lines are to be cut or disconnected from the equipment to insert the SPD. The LINE SIDE terminals of the protector are to be connected to the field loop wires. The EQUIPMENT SIDE of the protector is connected to the equipment/ controller, etc. The location of the protector should be as close to the equipment requiring protection. Operating Temperature VALUE -55 to 100 °C °C-55 to 100 UNITSPARAMETER Storage Temperature Operating Line Current 100 mA MAXIMUM RATINGS @ 25°C Unless Otherwise Specified Transient Source Voltage 6k V Transient Current (8/20µs) - Per Line 10 kA PART NUMBER MAXIMUM OPERATING LINE VOLTAGE VOP ±VOLTS MAXIMUM CLAMPING VOLTAGE (8/20µs) @ 2000A VC VOLTS MAXIMUM LINE THRUPUT RESISTANCE R OHMS 420E212 420E225 420E228 420E236 420E250 420E260 12.0 25.0 28.0 36.0 50.0 60.0 MAXIMUM CAPACITANCE @ 0V, 1MHz C PF 6000 3000 2800 1500 1200 1000 MAXIMUM LEAKAGE CURRENT WM ID µA 5.0 5.0 5.0 5.0 5.0 5.0 ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified

305053.R4 7/04 www.protekdevices.com 420E212 thru 420E260 PACKAGE OUTLINE & DIMENSIONS COPYRIGHT © ProT ek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the s election or specifications of such products. ProTek Devices

2929 South Fair Lane, Tempe, AZ 85282

Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com 420E2 CASE OUTLINE /MT49/MT46/MT52/MT48/MT148/MT32/MT77/MT65/MT88 /MT40/MT51/MT53/MT46/MT53/MT54/MT109/MT109/MT41 /MT50/MT46/MT53/MT48/MT148/MT32/MT78/MT79/MT77 /MT40/MT54/MT51/MT46/MT53/MT48/MT109/MT109/MT41 /MT49/MT46/MT50/MT48/MT148/MT32/MT77/MT65/MT88 /MT40/MT51/MT48/MT46/MT52/MT56/MT109/MT109/MT41 /MT76/MT73/MT78/MT69 /MT83/MT73/MT68/MT69 /MT69/MT81/MT85/MT73/MT80/MT77/MT69/MT78/MT84 /MT83/MT73/MT68/MT69 /MT49 /MT71/MT78/MT68 /MT50 /MT48/MT46/MT54/MT55/MT53/MT148/MT32/MT77/MT65/MT88 /MT40/MT49/MT55/MT46/MT49/MT53/MT109/MT109/MT41 /MT49 /MT71/MT78/MT68 /MT50