419EA MACOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Datasheet Rev. GG1 Issued 2007/07 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays SCHRACK Rast 5 Power Relay 419 11 (EA/..) I 2 pole 16 A I Safety mains insulation I Quick connect terminals 6.3 x 0.8 mm I Contact gap > 3 mm I 4 kV / 8 mm coil-contact I Snap or screw mounting I Product in accordance to IEC60335-1 I RoHS compliant (Directive 2002/95/EC) as per product date code 0349

Applications

Industrial and domestic appliances, heating controls, absolute safe power supply disconnection F0255-BI Approvals VREG.-Nr. 5064 ÜG, ZE214024 Technical data of approved types on request Contact data Contact configuration 2 NO Contact set bifurcated contacts Type of interruption full disconnection Rated current 16 A Rated voltage / max.switching voltage AC 240/400 VAC Limiting making capacity, max 4 s, duty factor 10% 25 A Contact material AgCu3 Contact gap > 3 mm Mechanical endurance DC-coil 2x10 6 cycles AC-coil 0,5x10 6 cycles Rated frequency of operation with / without load 15 / 600 min -1 Contact ratings Type Load Cycles DC Version 16 A, 250 VAC, cos ϕ=1 5x10 5 DC Version 12 A, 400 VAC, cos ϕ=1 2,5x10 5 DC Version 20 A, 250 VAC, cos ϕ=1 6x10 3 AC Version 16 A, 250 VAC, cos ϕ=1 2,5x10 5 Coil data Rated coil voltage range DC coil 6...60 VDC AC coil 24...400 VAC Coil power DC coil 0,72 W AC coil 2,2 VA Operative range DC coil / AC coil 1 / 2 Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 10 6 3.5 0.4 50 +10% 720 11 10 6.0 0.7 150 +10% 667 12 12 7.5 0.9 200 +10% 720 13 24 15.0 1.8 800 +10% 720 Coil versions, AC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VAC VAC VAC Ohm VA 01 200.50/60Hz 160.0 15.0 4050 +10% 2.2 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request

Datasheet Rev. GG1 Issued 2007/07 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays SCHRACK Rast 5 Power Relay 419 11 (EA/..) (Continued) Insulation Dielectric strength coil-contact circuit 4000 V rms open contact circuit 2000 V rms adjacent contact circuits 4000 V rms Clearance / creepage coil-contact circuit W 6 / 8 mm Material group of insulation parts W IIIa Tracking index of relay base PTI 380M Insulation to IEC 60664-1 Type of insulation coil-contact circuit reinforced open contact circuit basic adjacent contact circuits reinforced Rated insulation voltage 250 V Pollution degree 3 Rated voltage system 230/400 V Overvoltage category III Other data RoHS - Directive 2002/95/EC compliant as per product date code 0349 Ambient temperature range -20...+85°C Operate- / release time typ. 15 / 12 ms Bounce time NO typ. 8 ms Vibration resistance (function) NO (5...500Hz) 2 g Shock resistance (destruction) 80 g Category of protection RTI - dust protected Mounting snap or screw mounting Relay weight 92 g Packaging unit 50 pcs Dimensions S0470-A

Datasheet Rev. GG1 Issued 2007/07 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Rast 5 Power Relay 419 11 (EA/..) (Continued) SCHRACK Product key 0419 0 1 00 Type Mounting 1 Snap mounting, 1.0 mm panel 2 Snap mounting, 1.5 mm panel

3 Screw mounting

Coil code: please refer to coil versions table Contact material

0 AgCu 3

1 Silver plated

00 Standard

Product key Version Cont-material Cont.configuration Coil Coil Part number 0419 11 0301 00 Snap Mounting AgCu3 2 NO AC-coil 230 VAC 3-1415419-5 0419 11 1201 00 1.0 mm plate contacts DC-coil 12 VDC 4-1415419-0 0419 11 1301 00 24 VDC 4-1415419-2 0419 31 0301 00 Screw Mounting AC-coil 230 VAC 4-1415419-9 0419 31 1301 00 DC-coil 24 VDC 5-1415419-5