417 LITTELFUSE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
WebSite:WebSite:WebSite:WebSite:WebSite: www.wickmann.com • EuropeEuropeEuropeEuropeEurope Tel: +49 (2302) 662-107 • AmericasAmericasAmericasAmericasAmericas Tel: +1 (404) 699-7820 • AsiaAsiaAsiaAsiaAsia Tel: +852 26 14-1108 FaxBack: +1 (404) 699-6176 E-mail: sales@wickmann.com E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk WICKMANN 000801000801000801000801000801 400mA 0400 125V 440 180 0.031 • • 500mA 0500 125V 420 210 0.036 • • 630mA 0630 125V 400 255 0.05 • • 800mA 0800 125V 350 280 0.17 • • 1.00A 1100 125V 200 200 0.2 • • 1.25A 1125 125V 195 245 0.31 • • 1.60A 1160 125V 190 305 0.53 • • 2.00A 1200 125V 185 370 0.95 • • 2.50A 1250 125V 180 450 1.5 • • 3.15A 1315 125V 175 555 2.6 • • 4.00A 1400 125V 170 680 4.5 • • 5.00A 1500 125V 150 750 8.1 • • 6.30A 1630 75V 100 630 14 • • 7.00A 1700 75V 95 665 16 • • 8.00A 1800 75V 90 720 18 • • 10.00A 2100 75V 85 850 24 • • UR CSA 50A / 75VAC 50A / 60VDC 50-60Hz cos j = 1.0 1,4 ±0,2 6,0 ±0,2 1,4 ±0,2 2,5 ±0,2 2,5 ±0,2 3,2 +0,05 3,15 +0,05 3,2 +0,05 3,75 +0,05 50A / 125VAC 50A / 60VDC 50-60Hz cos j = 1.0 SSSSSURFACEURFACEURFACEURFACEURFACE M M M M MOUNTOUNTOUNTOUNTOUNT F F F F FUSESUSESUSESUSESUSES SMQ / No. 417/418417/418417/418417/418417/418 Dimensions (mm)Dimensions (mm)Dimensions (mm)Dimensions (mm)Dimensions (mm) InformationInformationInformationInformationInformation NumberNumberNumberNumberNumber Pad LayoutPad LayoutPad LayoutPad LayoutPad Layout Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Approvals Current Code Rating Capacity 1.0 x I Rated 1.0 x I Rated 10 x I Rated Limits for Pre-arcing TimeLimits for Pre-arcing TimeLimits for Pre-arcing TimeLimits for Pre-arcing TimeLimits for Pre-arcing Time UL 248-14, 125VUL 248-14, 125VUL 248-14, 125VUL 248-14, 125VUL 248-14, 125V , F, F, F, F, F Time-Current CharacteristicTime-Current CharacteristicTime-Current CharacteristicTime-Current CharacteristicTime-Current Characteristic Quick Acting (F) StandardStandardStandardStandardStandard UL 248-14 CSA C22.2 No. 248.14 ApprovalsApprovalsApprovalsApprovalsApprovals UL Recognized: File No. E 67006 CSA Certified: File No. LR 702775 FeaturesFeaturesFeaturesFeaturesFeatures Flame resistant ceramic housing For line or low voltage applications Low voltage drop Internationally approved WWWWWebLinksebLinksebLinksebLinksebLinks Data SheetData SheetData SheetData SheetData Sheet www.wickmann.com/products/417.pdf Approval CertificatesApproval CertificatesApproval CertificatesApproval CertificatesApproval Certificates www.wickmann.com/approvals TTTTTime-Current Curveime-Current Curveime-Current Curveime-Current Curveime-Current Curve Page 70 www.wickmann.com/itcurves PackagingPackagingPackagingPackagingPackaging Page 118 www.wickmann.com/pack FaxBack Document # 325FaxBack Document # 325FaxBack Document # 325FaxBack Document # 325FaxBack Document # 325 SpecificationsSpecificationsSpecificationsSpecificationsSpecifications PackagingPackagingPackagingPackagingPackaging 000: Blister Tape (1000 pcs.) MaterialsMaterialsMaterialsMaterialsMaterials Housing: Ceramic Element: Wire Terminals: Copper alloy, tin plated Operating TOperating TOperating TOperating TOperating T emperatureemperatureemperatureemperatureemperature -55ºC to +125ºC (consider de-rating) Stock ConditionsStock ConditionsStock ConditionsStock ConditionsStock Conditions +10ºC to +60ºC relative humidity £ 75% yearly average, without dew, maximum value for 30 days-95% VVVVVibration Resistanceibration Resistanceibration Resistanceibration Resistanceibration Resistance 2 hrs. in each axis 10 - 55 - 10Hz at 1.5mm amplitude SolderabilitySolderabilitySolderabilitySolderabilitySolderability 235ºC, 3 sec. (IEC 60068-2-58) Soldering Heat ResistanceSoldering Heat ResistanceSoldering Heat ResistanceSoldering Heat ResistanceSoldering Heat Resistance 260ºC, 10 sec. (IEC 60068-2-58) Minimum Cross Section, CopperMinimum Cross Section, CopperMinimum Cross Section, CopperMinimum Cross Section, CopperMinimum Cross Section, Copper Conducting path - 0.1mm 2 (417) / 0.2mm 2 (418) Path thickness - 0.035mm (417) / 0.07mm (418) MountingMountingMountingMountingMounting Solder the fuse with the marked side facing up Avoid circuit traces below the fuse MarkingMarkingMarkingMarkingMarking , Current Rating Unit WUnit WUnit WUnit WUnit W eighteighteighteighteight 0.23g (approx.) Reflow Wave Rated Current 2.0 x I Rated 2.0 x IRated 400mA ... 10.00A < 60s < 5s
WebSite:WebSite:WebSite:WebSite:WebSite: www.wickmann.com • EuropeEuropeEuropeEuropeEurope Tel: +49 (2302) 662-107 • AmericasAmericasAmericasAmericasAmericas Tel: +1 (404) 699-7820 • AsiaAsiaAsiaAsiaAsia Tel: +852 26 14-1108 FaxBack: +1 (404) 699-6176 E-mail: sales@wickmann.com E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk WICKMANN 000801000801000801000801000801 SSSSSURFACEURFACEURFACEURFACEURFACE M M M M MOUNTOUNTOUNTOUNTOUNT F F F F FUSESUSESUSESUSESUSES SMQ / No. 417417417417417 Contact WICKMANN for individual I-t curves IIIIIFaultFaultFaultFaultFault / I / I / I / I / I RatedRatedRatedRatedRated 23 4 5 6 7 8 911 0 0.001 0.01 0.1 100 1,000 10,000 100,000 151.5 UL 248-14 Test value I-t Characteristics (M in-M ax Limit)