GWF402 HONEYWELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

 Flex 402: Two Style B (Class B) IDC zones, one Style Y (Class B) NAC  Flex 404: Four Style B (Class B) IDC zones, two Style Y (Class B) NACs  Optional NAC Class A converter module (Flex 404)  NAC synchronization and programmability features: - ADA compliant strobe synchronization - ANSI audible signals as required by NFPA 72 - Silence inhibit, auto-silence, non-silenceable - Selective Silence: mute horns, keep strobes lit - Temporal or steady signal  Silent or audible walk test from front keypad  Zone disable, alarm verification selectable per zone  Controls: Acknowledge, Alarm, Silence, Reset, Walktest, Zone enable/disable  LED indicators: Alarm, Supervisory, Maintenance, Trouble (one per zone): AC, NAC / Zone disable, NAC fault, System / Power Trouble, Walktest, Alarm Silence, Charger / Battery / Earth Fault (on pcb)  Alarm verification  Low AC voltage sense, automatic battery charger  Piezo sounder for alarm, trouble, and supervisory GWF402 (left) and GWF404 (right)

12 Clintonville Road, Northford, CT 06472-1610 USA  Tel: (203) 484-7161  Fax: (203) 484-7118

9021-60292 Rev. A page 2 of 2 www.gamewell-fci.com Options CAC-4 Used to convert Style B (Class B) IDCs to Style D (Class A) and Style Y (Class B) NACs to Style Z (Class A). Mounts in FA C P. F l e x 4 0 4 o n l y. XRM-24 Second 100VA transformer for maximum accessory power. Mounts in FACP . Flex 404 only. 4XTMF Transmitter module provides output for local energy municipal box transmitter and alarm and trouble reverse polarity. Mounts in FACP . Flex 402 & Flex 404. 4XZMF Zone relay module provides Form-C relays: Alarm Zones 1, 2, 3, 4, System Alarm, Trouble. Mounts in FACP . Flex 404 only. 4XLMF LED interface module supports the GWSAN-404 remote annunciator, supervises annunciator wiring for open conditions. Mounts in FACP . Flex 404 only. 411UD Four input/channel, dual line, digital alarm communicator/transmitter(DACT). Input/ channels are compatible with normally open relay contacts, are supervised and fully programmable. Interfaces with public switched telephone networks and compatible with most central station receiv- ers. Flex 404 only. GWSAN-404 Remote annunciator mounts in single-gang electrical box, provides LED indication of Alarm Zones 1, 2, 3, 4; and System Trouble. Flex 404 only. Specifications AC Power 120 VAC, 50/60Hz, 2.3 A Battery Max. charging circuit: 27.6 VDC@ 0.8A Max. charger capacity: 18 Ah (two 7Ah batteries fit inside FACP) Initiating Device Alarm zones 1 & 2 (Flex 402 / Flex 404) Circuits (IDC) Alarm zones 3 & 4 (Flex 404 only) Operation: All zones Style B (Class B) Power limited circuitry Operating voltage: nominal 20 VDC Alarm current: 15 mA minimum Short circuit current: 40 mA maximum Standby current: 4 mA Maximum loop resistance: 100 ohms Notification One NAC: Flex 402; two NACs:Flex 404 Specifications (Continued) Circuits (NAC) Operation: Style Y (Class B) Power limited circuitry Operating voltage: nominal 24 VDC Maximum signaling current: 2.5 A total (5.0 A Flex 404 with optional transformer) Maximum line impedance: 1.5 volt drop Form-C Relays Trouble, Alarm (Supervisory, Flex 404) Contact ratings 2 A @ 30 VAC (resistive) Resettable Operating voltage: nominal 24 VDC power Power limited circuitry Maximum available current: 500 mA Nonresettable Operating voltage: nominal 24 VDC power Power limited circuitry Maximum Available current: 500 mA Cabinet Door: 15.3" x 14.7" x 0.3" (39 x 37 x 1 cm) Backbox: 15.0" x 14.5" x 3.0" (38 x 37 x 8 cm)

Ordering Information

GWF402 Flex 402 conventional FACP , 2 zones,

120 VAC, red

GWF404 Flex 404 conventional FACP , 4 zones, 71252 EOL resistor, 4.7K ohm, ½ watt

52194 Flex 402 and Flex 404 Installation &

Options: CAC-4 Class A converter for initiating device circuits and notification appliance cir- cuits (cannot be used on Flex 402) XRM-24 Transformer, expands NAC circuit power from 3 to 5 amps 4XTMF Transmitter module for remote station output or municipal box connection 4XZMF Relay module, four relays-by-zone, alarm and trouble contacts, 24VDC 4XLMF Remote annunciator driver, 24 VDC, supports GWSAN-404 411UD Four channel dual slave programmer DACT, Form C relay and upload/down- load capability; with enclosure, requires PRO-411 PRO-411 Programmer, use with 411UD, 411UDAC GWSAN-404 LED remote annunciator for Flex 404, 4 alarms, 1 trouble (requires 4XLMF) BB-17F Battery box, houses 2 batteries (7-18 Ah max)