GWF402 HONEYWELL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
Flex 402: Two Style B (Class B) IDC zones, one Style Y (Class B) NAC Flex 404: Four Style B (Class B) IDC zones, two Style Y (Class B) NACs Optional NAC Class A converter module (Flex 404) NAC synchronization and programmability features: - ADA compliant strobe synchronization - ANSI audible signals as required by NFPA 72 - Silence inhibit, auto-silence, non-silenceable - Selective Silence: mute horns, keep strobes lit - Temporal or steady signal Silent or audible walk test from front keypad Zone disable, alarm verification selectable per zone Controls: Acknowledge, Alarm, Silence, Reset, Walktest, Zone enable/disable LED indicators: Alarm, Supervisory, Maintenance, Trouble (one per zone): AC, NAC / Zone disable, NAC fault, System / Power Trouble, Walktest, Alarm Silence, Charger / Battery / Earth Fault (on pcb) Alarm verification Low AC voltage sense, automatic battery charger Piezo sounder for alarm, trouble, and supervisory GWF402 (left) and GWF404 (right)
12 Clintonville Road, Northford, CT 06472-1610 USA Tel: (203) 484-7161 Fax: (203) 484-7118
9021-60292 Rev. A page 2 of 2 www.gamewell-fci.com Options CAC-4 Used to convert Style B (Class B) IDCs to Style D (Class A) and Style Y (Class B) NACs to Style Z (Class A). Mounts in FA C P. F l e x 4 0 4 o n l y. XRM-24 Second 100VA transformer for maximum accessory power. Mounts in FACP . Flex 404 only. 4XTMF Transmitter module provides output for local energy municipal box transmitter and alarm and trouble reverse polarity. Mounts in FACP . Flex 402 & Flex 404. 4XZMF Zone relay module provides Form-C relays: Alarm Zones 1, 2, 3, 4, System Alarm, Trouble. Mounts in FACP . Flex 404 only. 4XLMF LED interface module supports the GWSAN-404 remote annunciator, supervises annunciator wiring for open conditions. Mounts in FACP . Flex 404 only. 411UD Four input/channel, dual line, digital alarm communicator/transmitter(DACT). Input/ channels are compatible with normally open relay contacts, are supervised and fully programmable. Interfaces with public switched telephone networks and compatible with most central station receiv- ers. Flex 404 only. GWSAN-404 Remote annunciator mounts in single-gang electrical box, provides LED indication of Alarm Zones 1, 2, 3, 4; and System Trouble. Flex 404 only. Specifications AC Power 120 VAC, 50/60Hz, 2.3 A Battery Max. charging circuit: 27.6 VDC@ 0.8A Max. charger capacity: 18 Ah (two 7Ah batteries fit inside FACP) Initiating Device Alarm zones 1 & 2 (Flex 402 / Flex 404) Circuits (IDC) Alarm zones 3 & 4 (Flex 404 only) Operation: All zones Style B (Class B) Power limited circuitry Operating voltage: nominal 20 VDC Alarm current: 15 mA minimum Short circuit current: 40 mA maximum Standby current: 4 mA Maximum loop resistance: 100 ohms Notification One NAC: Flex 402; two NACs:Flex 404 Specifications (Continued) Circuits (NAC) Operation: Style Y (Class B) Power limited circuitry Operating voltage: nominal 24 VDC Maximum signaling current: 2.5 A total (5.0 A Flex 404 with optional transformer) Maximum line impedance: 1.5 volt drop Form-C Relays Trouble, Alarm (Supervisory, Flex 404) Contact ratings 2 A @ 30 VAC (resistive) Resettable Operating voltage: nominal 24 VDC power Power limited circuitry Maximum available current: 500 mA Nonresettable Operating voltage: nominal 24 VDC power Power limited circuitry Maximum Available current: 500 mA Cabinet Door: 15.3" x 14.7" x 0.3" (39 x 37 x 1 cm) Backbox: 15.0" x 14.5" x 3.0" (38 x 37 x 8 cm)
Ordering Information
GWF402 Flex 402 conventional FACP , 2 zones,
120 VAC, red
GWF404 Flex 404 conventional FACP , 4 zones, 71252 EOL resistor, 4.7K ohm, ½ watt
52194 Flex 402 and Flex 404 Installation &
Options: CAC-4 Class A converter for initiating device circuits and notification appliance cir- cuits (cannot be used on Flex 402) XRM-24 Transformer, expands NAC circuit power from 3 to 5 amps 4XTMF Transmitter module for remote station output or municipal box connection 4XZMF Relay module, four relays-by-zone, alarm and trouble contacts, 24VDC 4XLMF Remote annunciator driver, 24 VDC, supports GWSAN-404 411UD Four channel dual slave programmer DACT, Form C relay and upload/down- load capability; with enclosure, requires PRO-411 PRO-411 Programmer, use with 411UD, 411UDAC GWSAN-404 LED remote annunciator for Flex 404, 4 alarms, 1 trouble (requires 4XLMF) BB-17F Battery box, houses 2 batteries (7-18 Ah max)