http://www.agelectronica.com 40D2405 CONVERTIDOR DC-DC ENTRADA (18V-36V) 5V 8A 40W Multiple specifications of power module options MULTIPLE SPECIFICATIONS AVAILABLE Wide voltage 24V (18-36V) input 40W regulated output MODEL POWER VOLTAGE ELECTRICITY HLK-40D2405 40W 5V 8000mA HLK-40D2412 40W 12V 3333mA HLK-40D2415 40W 15V 2667mA HLK-40D2424 40W 24V 1666mA *The same series of products have the same size and pin package *International standard pin size 50.8x50.8x 12.7mm product features PRODUCT FEATURES  Ultra-thin international standard size and lead package  Wide range input voltage: 18~36VDC  Ultra-low standby power consumption 0.036W (typical value)  Input and output isolation withstand voltage 1500VDC  Ultra-fast start: 1ms (typical value)  High efficiency, conversion efficiency up to 91% (Typ)  Operating temperature range: -40°C~+85°C  Good output short circuit and over current protection and self-recovery  High reliability, long life design, continuous work>100000H  It is potted with high-quality environmentally friendly waterproof and thermal conductive glue, moisture-proof and vibration-proof, and meets the waterproof and dust-proof IP65 standard  Meet UL/CE/EMC and safety testing requirements  Can be used in medical, industrial control, electric power, instrumentation, communication, railway and other fields

http://www.agelectronica.com Working environment temperature and load characteristics WORKING ENVIRONMENT tempeRature & LOAD CHARACTERISTICS Typical application circuit APPLICATION CIRCUIT Recommended test circuit Generally recommended capacitance: C1: 47-100μF/50V; C2, C3: 10-22μF. All DC/DC converters of this series are tested according to the recommended test circuit shown in the figure below before leaving the factory. If it is required to further reduce the input and output ripple, the input and output external capacitors C1, C2, C3 can be increased or selected in series with capacitors with a small equivalent impedance, but the capacitance cannot be greater than the maximum capacitive load of the product.

http://www.agelectronica.com EMC solution-recommended circuit Recommended parameters: FUSE: Connect the corresponding fuse according to customer needs MOV varistor: 14D333K LDM1/common mode inductance: 2mH E1, E2 electrolytic capacitors: 470μF/50V C0, C1 ceramic capacitors: 1μF/50V LDM2 differential mode inductor: 4.7-68μH CY1 safety Y2 capacitor: 1nF/250Vac Output filter peripheral recommended circuit Note: 1. C2 and C3 use high-frequency and low-resistance electrolytic capacitors, and the total capacity cannot exceed the maximum capacitive load marked in the manual, otherwise the module will not start normally. 2. For capacitive load, a minimum load of 3% must be guaranteed, otherwise it will cause abnormal output of the module.

http://www.agelectronica.com Recommended parameters: Device code 5V output 9V/12V/15V output 24V output LDM3/4 inductance 1μH 2.2μH 4.7μH C2/3 electrolytic capacitor 220μF 100μF 68μF C4 ceramic capacitor 1μF/50V Use of Trim and calculation of Trim resistance The Trim output voltage adjustment terminal with Trim terminal

http://www.agelectronica.com system is as follows: The output voltage R1(KΩ) R2(KΩ) R3(KΩ) Vref 5V 45.3 14.778 84.5 1.25 9V 30 11.441 120 2.5 12V 45.3 14.571 84.5 2.5 15V 56 11.441 154 2.5 24V 84.5 9.791 84.5 2.5 Ripple & noise test: twisted pair method 20MHz bandwidth testing method: 1. Ripple noise is connected using 12# twisted pair, the oscilloscope bandwidth is set to 20MHz, 100M bandwidth probe, and 0.1uF polypropylene capacitor and 47uF high frequency low resistance electrolytic capacitor are connected in parallel to the probe end, and the oscilloscope sampling uses Sample sampling mode . 2. Connect the power input terminal to the input power source, and connect the power output to the electronic load through the fixture board. Use a 30cm±2cm sampling line to sample directly from the power output port for testing. The power line selects the corresponding wire diameter wire with insulation according to the output current. (As shown in FIG)

http://www.agelectronica.com Dimensions and weight DIMENSIONS & WEIGHT Pin description: 1: -Vin input negative; 2: +Vin input positive; 3: +Vo output positive; 4: NC; 5: -Vo output negative; 6: NC *Note: If the definition of each pin of the power module is not consistent with the selection manual, the label on the physical label shall prevail. República del Salvador N° 20 Segundo Piso Teléfono: 55 5130 - 7210 ACOTACIÓN: N/A http://www.agelectronica.com ESCALA: N/A REALIZO: OGJ REV: JFRR TOLERANCIA: N/A CONVERTIDOR DC-DC ENTRADA (18V-36V) 5V 8A 40W TOLERANCIA: N/A Fecha: 15/06/2022 No. Parte: 40D2405