4060 3M | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

comfort and durability. State-of-the-art features help provide unsurpassed comfort. Soft Seal Design

  • Advanced silicone material provides a softer feel on the face.
  • Unique adjustment design helps reduce pressure points on the face for unsurpassed comfort. Dual-mode head harness Unique head harness design adjusts easily so user has the option of wearing the respirator in either traditional or drop-down modes. Durable and heat-resistant
  • Made from soft, resilient silicone and heat-resistant plastics. Suggested Applications
  • Abatement
  • Painting
  • Welding
  • Chemical handling
  • Battery manufacturing
  • Construction
  • Utilities
  • Mining
  • Pharmaceutical
  • Smelting ™ Cool Flow™ Exhalation Valve Unique valve design helps make breathing easier, and helps reduce heat and moisture buildup in the facepiece. The Cool Flow ™ Exhalation Valve opens easier The chart shows exhalation breathing resistance on 3M and competitive half facepiece respirators. As you can see, the

7500 Series has measurably lower

exhalation breathing resistance at all work levels tested. Half Facepiece Respirators

7500 Series, Ultimate Reusable

3M™ Half Facepiece Respirators 7500 Series, Ultimate Reusable Issue Date 7/1/09 3M™ Cool Flow™ Exhalation Valve WARNING These respirators help protect against certain airborne contaminants. Misuse may result in sickness or death. Before use, the wearer must read and understand User Instructions provided as a part of product packaging. Time use limitations may apply. Call 3M OH&ESD Technical Service at 1-800-243-4630. In Canada, call 1-800-267-4414. Important Before using these respirators, you must determine the following: 1. The type of contaminant(s) for which the respirator is being selected. 2. The concentration level of contaminant(s). 3. Whether the respirator can be properly fitted on the wearer’s face. All respirator instructions, warnings and use and time limitations must also be read and understood by the wearer before use. Before use of these respirators, a written respiratory protection program must be implemented, meeting all the requirements of OSHA 29 CFR 1910.134, including training, medical evaluation and fit testing.

3M™ Half Facepiece Respirators 3M™ Cartridges 6000 Series Product Number NIOSH Approval* Product Number NIOSH Approval*

6001 Certain organic vapors (a)(b) 60921 P100/Certain organic vapors (a)(b)

6002 Chlorine, hydrogen chloride, and sulfur dioxide

or chlorine dioxide or hydrogen sulfide (a)(b)

60922 P100/Chlorine, hydrogen chloride, and sulfur dioxide or

chlorine dioxide or hydrogen sulfide (a)(b)

6003 Certain organic vapors, chlorine, hydrogen chloride,

and sulfur dioxide or hydrogen sulfide or hydrogen fluoride (a)(b)

60923 P100/Certain organic vapors, chlorine, hydrogen

chloride, and sulfur dioxide or hydrogen sulfide or hydrogen fluoride (a)(b)

6004 Ammonia and methylamine (a)(b) 60924 P100/Ammonia and methylamine (a)(b)

6005 Formaldehyde and certain organic vapors (a)(b) 60925 P100/Formaldehyde and certain organic vapors (a)(b)

6006 Certain organic vapors, chlorine, hydrogen chloride,

chlorine dioxide, sulfur dioxide, hydrogen sulfide ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c)

60926 P100/Certain organic vapors, chlorine, hydrogen

chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c)

60928 P100/Organic vapor/Acid gas (d)

6009 Mercury vapor or chlorine gas (a)(b) 60929 P100/Mercury vapor or chlorine gas (a)(b)

  • For respiratory protection against the following contaminants up to 10X PEL with half facepiece respirators and full facepiece respirators when qualitatively fit tested, or 50X PEL with full facepiece respirators when quantitatively fit tested. (a) All respirators and respirator/filter assemblies can be used up to the NIOSH approval limits, 10X PEL for half facepiece respirators and full facepiece respirators when qualitatively fit tested, or 50X PEL for full facepiece respirators when quantitatively fit tested or the maximum use concentration allowable in applicable OSHA standards, whichever is lower. (b) For specific usage, limitations and warning information, see respirator and/or filter packaging, or call 3M OH&ESD Technical Service 1-800-243-4630. In Canada call 1-800-267-4414. (c) OSHA regulations require that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde. (d) As recommended by the California Department of Pesticide Regulation No. 01-099 Methyl Bromide Field Fumigation. *Nuisance levels refer to concentrations below the OSHA PEL or other government standard, whichever is lower. 2291 P100 Filter 2296 P100 Filter with nuisance level acid gas relief* 2297 P100 Filter with nuisance level organic vapor relief* 7093 P100 Filter 7093C/37173 P100 Cartridge/Filter with hydrogen fluoride, nuisance level organic vapor and acid gas relief* 603 Filter Adapter (Use with the 5N11 or 5P71 Filters and

501 Filter Retainer)

N95 Filter (Use with the

501 Filter Retainer and

6000 Series cartridges)

P95 Filter (Use with the Filter Retainer (Use with 5N11 and 5P71 Filters and Filter Adapter (Use with 2000 and 2200 Series and 7093 Filters and 6000 Series cartridges) 3M™ Filters and Accessories 2000 and 2200 Series, 7093, 5N11, 5P71 2071 P95 Filter 2076HF P95 Filter with hydrogen fluoride, nuisance level acid gas relief* 2078 P95 Filter with nuisance level organic vapor and acid gas relief* P100 Filter 2096 P100 Filter with nuisance level acid gas relief* P100 Filter with nuisance level organic vapor relief*

3M™ Half Facepiece Respirators 3M™ Quantitative Fit Test Adapter 601 (for use with all 3M bayonet attachment facepieces) 3M™ Fit Test Kits

  • FT-10 Qualitative Fit Test Apparatus (sweet solution)
  • FT-20 Training and Fit Testing Case (sweet solution)
  • FT-30 Qualitative Fit Test Apparatus (bitter solution)

Ordering Information

Half Facepiece, Silicone, Small 1 facepiece/bag, 10 bags/case = 10 Each 7502 5 00 51131 37082 6 70-0710-4278-5 Half Facepiece, Silicone, Medium 1 facepiece/bag, 10 bags/case = 10 Each 7503 5 00 51131 37083 8 70-0710-4279-3 Half Facepiece, Silicone, Large 1 facepiece/bag, 10 bags/case = 10 Each Spare Parts Part Number Description 7580 5 00 51131 17223 9 70-0715-3429-4 Respirator Replacement Strap 10 straps/bag, 4 bags/case = 40 Each 7581 5 00 51131 52753 4 70-0710-4260-3 Head Harness Assembly 5 each/bag, 4 bags/case = 20 Each 7582 5 00 51131 52754 1 70-0710-4261-1 Inhalation Valve 10 valves/bag, 1 bag/case = 10 Each 7583 5 00 51131 52755 8 70-0710-4262-9 Exhalation Valve 10 valves/bag, 1 bag/case = 10 Each 7586 5 00 51131 52756 5 70-0710-4263-7 Cartridge Filter Holder (Includes Valves) 5 each/bag, 4 bags/case = 20 Each Occupational Health and Environmental Safety Division 3M Center, Building 235-2E-91 St. Paul, MN 55144-1000 For more information, please contact: 3M Occupational Health and Environmental Safety Division (OH&ESD) In the U.S., contact: Customer Service 1-800-328-1667 Technical Assistance 1-800-243-4630 Website www.3M.com/OccSafety For other 3M products 1-800-3M HELPS In Canada, contact: 3M Canada Company, OH&ESD P.O. Box 5757 London, Ontario N6A 4T1 Customer Care 1-800-364-3577 Technical Assistance (Canada only) 1-800-267-4414 Website www.3M.ca/safety Technical Assistance In Mexico 01-800-712-0646 5270-2255, 5270-2119 (Mexico City only) Technical Assistance In Brazil 0800-132333