4000 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

  • Highly accurate PT1000 RTD (Class AA)
  • 5.9mm diameter brass probe
  • IP69K
  • -40 - 85°C operating temperature range
  • 100nF Capacitor for electrical noise reduction
  • Outer polyolefin heatshrink
  • RoHS compliant

Applications

  • HVAC Equipment
  • Heat Pumps
  • Water Heaters
  • Industrial Heating and Cooling Equipment The 4000 series temperature sensor probe is a universal cable temperature sensor probe utilizing a highly accurate Class AA PT1000 RTD. The sensor is based on a small diameter brass housing for fast response time with a four crimp seal to the silicon wire insulation for increased ingress protection. The 4000 series also offers adhesive-lined heatshrink over the housing to wire connection for added wire strain relief and further robustness to moisture ingress. Built for tough applications the 4000 series is an ideal choice for HVAC equipment, heat pumps, water heaters, industrial heating and cooling equipment. Output at Temperature 1000 ohms at 0°C PTC -40-0°C: R(t) = R0 x (1+At+Bt2+C[t-100]t3) 0-85°C: R(t) = R0 x (1+At+Bt2) R0 = 1000 A = 3.91x10-3 B = -5.78x10-7 C = -5.78x10-12 t = temperature in °C Accuracy(1) Class AA (F0.1) RTD with +/-0.1 °C accuracy at 0 °C Recommended Supply Current(2) ≤0.3 milliamps Output Response Time (T63) ≤18 seconds from stagnant ambient air temperature to 0°C glycol bath Surge Immunity IEC 6100-4-5, ten 1KV surge pulses using a 1.2/50 micro second profile

www.sensata.com Page 2 Copyright © 2021 Sensata Technologies Inc. DIMENSIONS Wire length will vary with options selected Physical Vibration 20-2000 Hz, 3 axis with imposed resonance frequencies (engine vibration)

33 Hz 25 G’s (transportation vibration)

Mechanical Shock 50 G’s, 3 axis per MIL-STD 202G Method 213B, Condition A Drop (any Axis) 1 meter Humidity 100% condensing Ingress Protection IP69K Operating Temperature -40°C to 85°C Storage Temperature -40°C to 100°C Schematic SPECIFICATION FOR SENSOR: 1. TEMPERATURE SENSOR ELEMENT: PT 1000 CLASS AA - ACCORDING TO IEC 6075, 1K Ω 0.1% @0 C. 2. ACCURACY TABLE ELEMENT: 3. OUTPUT TIME CONSTANT (63%) SHALL NO MORE THAN 56 SECONDS WHEN SOAKED AT -20 C AND EXPOSED TO 1000 FT/MIN. AIR AT 25 C. 4. SENSOR SHOULD HAVE LESS THAN 300 MICRO AMPS OF CURRENT APPLIED TO AVOID SELF HEATING OF THE SENSE ELEMENT. 5. INSULATION RESISTANCE BETWEEN BOTH LEADS AND THE CASE SHALL EXCEED 1000 MΩ AT ROOM TEMPERATURE WITH A MEGGER AT 500VDC. 6. OPERATING TEMPERATURE RANGE WILL BE: -40 C TO +85 C. 7. STORAGE TEMPERATURE RANGE WILL BE: -40 C TO +100 C. 8. RELATIVE HUMIDITY: 0% TO 100% CONDENSING. 9. REF. SPECIFICATION - 0800839144 REV. 5 AND TKS 28020. 10. DEVICE SHALL WITHSTAND 2000PSI PRESSURE WASH AT 10-30 C USIB=NG A FAN-SHAPED NOZZLE DIRECTED AT ALL MATERIAL INTERFACES FOR ONE MINUTE EACH 10CM DISTANCE AT ANY ANGLE. 11. BODY MATERIAL: BRASS 12. VIBRATION: THE SENSOR SHALL BE TESTED AGAINST VIBRATION PROFILE AS DESCRIBED BY TKS 28-020 "MEC01.2". 13. SHOCK: 50Gpk FOR 11ms PER MIL-STD-202F, METHOD 213B, CONDITION A. 14. THE SENSOR SHALL MEET IP59K REQUIREMENT. 15. ELECTROMAGNETIC COMPLIANCE: HARNESS SHALL BE 4 METER LENGTH. THE FOLLOWING TEST AND TEST LEVELS ARE APPLICABLE: 16. THE RTD COMPONENT SHALL BE OPERATIONAL FOR AT LEAST 10 YEARS FOR 4,000 HOURS OF OPERATING TIME PER YEAR. IT SHALL ALSO BE ABLE TO SURVIVE UP TO 2,920 DEFROST CYCLES PER YEAR WITH NO ADVERSE EFFECTS ON COMPONENT PERFORMANCE. ONE WAY TO PROVE PRODUCT LIFE REQUIREMENTS IS TO HAVE THE RTD TO PASS ICE BATH TO BOILING WATER TEST, HUMIDITY, HALT TESTING WITH VIBRATION, 1,800 CYCLES OF TEMPERATURE CYCLING AND SALT SPRAY FOG TEST AS DESCRIBED IN THE SECTION 4 & APPENDIX 8.1 IN THERMO KING SPECIFICATION 0800839144. ALTERNATIVE METHODS OF PROVING PRODUCT LIFE MUST BE DISCUSSED WITH THERMO KING. 17. SENSE ELEMENT TO DRIFT NO MORE THAN 0.102°C PER 1,000 HOURS AT 300°C. 18. ELECTRICAL COMPONENTS SHALL BE RoHS COMPLIANT. 19. COMPLY WITH BUT NOT CERTIFIED TO WEEE AND NSF/ANSI 2 - 2014. 20. CORROSIVE ENVIRONMENT: DEVICES SHALL WITHSTAND 700 HOURS EXPOSED TO ASTM B117. 21. MARKING SHALL BE LEGIBLE, CORROSION PIT DEPTH TO BE LESS THAN 10% OF WALL THICKNESS ON ANY SURFACE. 22. ALL CHANGES TO BE APPROVED BY THERMOKING ENGINEERING. 23. TEMPERATURE VS RESISTANCE RELATION: (REFER TABLE 1 AND PT 1000-RESISTANCE VS TEMPERATURE CURVE) FOR RANGE -50°C - 0°C: RT = R0[1+At+Bt +C(t-100)*t FOR RANGE 0°C - 300°C: RT = R0(1+At+Bt A = 0.00391 B = -0.000000578 C = -0.00000000000418 R0 = 1000 RT = RESISTANCE AT TEMPERATURE t = TEMPERATURE IN °C 24. CAPACITOR CAPACITANCE IS 100 +/- 10 NANOFARADS. RESISTANCE OHMS TEMPERATURE C 0.1 µF

100 VDC

0 C TO 85 C CLASS AA ACCORDING TO IEC 6075

-30 C TO 0 C CLASS A ACCORDING TO IEC 6075 -40 C TO -30 C CLASS B ACCORDING TO IEC 6075 ELECTRONIC DISCHARGE IEC 61000-4-2 THE DEVICE SHALL WITHSTAND UP TO 25KV AIR DISCHARGE AND UP TO 8KV CONTACT DISCHARGE USING THE STANDARD HBM SURGE IMMUNITY IEC 61000-4-5 THE DEVICE SHALL WITHSTAND TEN 1KV SURGE PULSES USING ASTANDARD 1.2/50US PROFILE SHEET 2 OF 2 4A10C-Z1E D REV. A DWG NO. SCALE N/A SOLIDWORKS

529 PLEASANT STREET

P.O. BOX 2964 ATTLEBORO, MA 02703 SIZE B C D 3 2 1 14 23 B D A C

+1 (888) 438 2214 sensors@sensata.com Europe, Middle East & Africa +31 (74) 357 8156 temperature-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82-10-9218-1179 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Page 3 Rev.04/16/2021 www.sensata.com CONTACT US Copyright © 2021 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. GENERAL NOTE (1) RTD accuracy specified based on RTD sense element. Additional packaging into full sensor probe may result in slight additional inaccuracies (2) Supply current above 0.3mA could lead to self-heating of the RTD and cause inaccurate temperature measurements AGENCY APPROVALS & CERTIFICATIONS Family

4000 Series

A= 2 in long brass tube RTD Selection 10= 1000Ω RTD Capacitor Option C= 0.1 uF Lead Termination A= Cut and Stripped Z= Custom *Consult factory Lead Length or Custom Identifier XX= Lead Length in inches (12” length standard, XX= 12) ORDERING OPTIONS Example : 4A10C-A12

4 A 10 C - A 12