4000-CU JDSU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

T-BERD®/MTS-400 0 M ultipleServicesTestPlatform Copper ServicesM odule Key Features • Completecoppertestingfrom POTS through full-spectrum VDSL/VDSL2 up to30 MHz

  • Time domain reflectometer(TDR) withtime-varying gain (TVG)
  • Spectralanalysisto30 MHz withone-buttonzoom to VDSL bands and causesofinterference
  • JDSU scripting and automated testfeaturesthatsimplify testing
  • Wideband copperfunctionalityavailableincombina tion withVDSL/VDSL2 testmodules
  • Large,colorgraphicaluserinterface(GUI) withoptional touchscreen The JDSU T-BERD/MTS-4000 equipped with the Copper ServicesMo dule deliverscompr ehensivecopper testingand addressesthe distinctrequirementsof veryhigh-speed digitalsubscriberline(VDSL)deployment and maintenance.The T-BER D/MTS-4000 isa rugged,m odularplatform engineeredwitha 7-inch color display,long battery life, and weather-resistantdesign for outstanding performance and reliabilityin thefield.The Copper ServicesModule bringsthe functionalityto the platform that serviceprovidersneed to mi tigate the significantchallenge of VDSL rolloutand maintenancein variousfiber(FTTx) deployments. Traditionally,thecopperplanthas not been qualified to withstandthe stringent needs of VDSL servicedelivery.The new spectrum thatV DSL usesintroduces more rigorousand stringentrequirements than previouslyseenin theinstalled plant.VDSL testinghas shown thattheplantis susceptibletoimpulsenoisenot encountered in the currentasymmetric digitalsubscriberline(ADSL) usage spectrum.Inaddition,thedetectionof shortbridgedtaps,which createa much greaterimpacton VDSL signalsthan on ADSL signals,becomes more criticalin VDSL testing.The T-BERD/MTS-4000 Copper ServicesModule teststo these standardsand more toqualifyand troubleshootthe copperforservice. The T-BERD/ MTS-4000 iseasily upgradeablew ithadvancedoptions thatsupport theindustry’schangingtechnologiesand theevolving needsof serviceinstallers. Itsdynamic configurabilityallowstechnicianswithvaryingresponsibilitiestouse itto perform a wide rangeof tests.StandardEthernetand universalserialbus (USB) or optionalWireless Fidelity(WiFi)and Bluetoothconnectionsoffer flexibilitytoeasilydownload softwareand offloadcapturedtestdatatoimprove workforceproductivityand baselinenetworkperformance. WEBSI TE :ww w.j dsu. com/test CO MMUNICATIO N S TEST & M EASUREMENT SOLUTIONS

Applications

  • Qualifiesand troubleshootstwisted paircopperdeployments
  • InteroperateswiththeJDSU UltraFed forsingle-ended closeout testing
  • Conductsscriptedcloseouttesting withuser-definablePass/Failcriteria

T-BERD/MTS -4000 COP PE R SERV ICES MODU LE A rchitecture Fullycompatible with theT-BERD/MTS-4000 mainframe,thedual-bayCopper Services Mod ule can be optionedwith a VDSL m odem to providesupportfor ADSL1/2/2+ , VDSL1, and VDSL/VDSL2 triple-play deployments.The Copper Services Module features dualTip (A)and Ring (B)(T&R , A&B )and Ground (Earth) interfaces.For the m ost accurateresults, technicianscan use specially insulatedcablesto testhigher-frequency services,suchasV DSL2. Internet and Triple-Play Services MDF Connection Issues RF Interference Impulse Noise Missing POTS Splitter CPE Interoperability Unterminated In-House Wiring Bridged Taps Unbalanced Loop Crosstalk Bad Contacts Corroded Contacts Figure1:Standardcopper qualificationm ay show acceptable resultsfortypicalproblem areassuch asattenuation and noise,but many issues impact copp erqualityintoday’sdemanding next-generationservice environment, particularlyunterminatedin-housewiringwithbridgedtaps thatlead tounexpected effectswhen using new frequencies up to30 MHz. The T-BERD/MTS-400 0 large,colorGUI ma kesreading even the mos tcomple x copper testresultseasy.

T-BERD/MT S-4000 COPPER SERVICE S MOD UL E Today’s copper network requiresrigoroustesting.The T-BERD/MTS-4000 equippedwithCopper ServicesModul esperforms theseessentialtestsand more: Overview ofCopp erTests Copper Test TestFunction What itTests Why itisNeeded FaultImp act DVOM DSL servicequalificationand DC/AC voltage,loopcurrent,loop Overallcopperhealth No DSL synchronizationorlow datarate troubleshooting resistance,distance-to-short,leakage Opens DSL servicequalificationand Capacitance,looplength Cabledamage, looplengthacceptable The longerthecable,thehigherthe troubleshooting forDSL attenuation,and thelowerthedatarate Load Coil DSL servicequalificationand Presenceofloadcoilsand location Load coilsactaslow-passfiltersand Load coilspreventDSL service troubleshooting must be removed POTS DSL withPOTS serviceinstallation Placinga POTS call Connectivitytoexchange No POTS and troubleshooting Balance DSL servicequalificationand Longitudinalbalance,Resistive Robustnessagainstnoise Noisedecreasesthebits-per-tone troubleshooting balance,Capacitivebalance load/datarate Noise DSL servicequalificationand Noisewithspecificband filters Externalnoisecorruptsgood data Noisedecreasesthebits-per-tone troubleshooting load/datarate ImpulseNoise DSL troubleshooting Voltagespikesabovespecificthresholds Intermittenteffectsthatcannotbe Impulsenoisemay leadtocontinuity correctedby forwarderrorcorrection errorsincludingIPTVpixilationand data (FEC) retransmission Loss DSL servicequalificationand Rx/TxTones Attenuationofcoppercable Reduced DSL datarate troubleshooting SNR DSL servicequalificationand Signalcompared tonoiselevel Enough margintosustaindataratein Temporarylossofsignalorreduceddata troubleshooting changingconditions ratepossible ReturnLoss DSL servicequalificationand Impedance mismatch Impedance mismatch—using multiple Reduced datarate troubleshooting cabletypes,causesenergytoreflect Near-EndCrosstalk(NEXT) DSL troubleshooting Noisefrom near-end Impactofmultiplebroadbandservices Reduced datarate inthecable SpectralAnalysis DSL troubleshooting Spectralnoiseperfrequency Identifythecharacteristicsofa noise Reduced datarate sourcetofixtheproblem TDR DSL troubleshooting Impedance anomaly and location Detectand locatefaultssuchasopens, No syncorreduceddatarate shorts,bridgedtaps,and wet sections RFL DSL troubleshooting Pairundertestagainsta reference Resistivefaultdetectionand location Reduced datarate usingohmmeter

Choose theT-BERD/MT S-4000 Function thatMeets Your Copper TestNeeds T-BERD/MTS -4000 COP PE R SERV ICES MODU LE The T-B ERD/ MTS-4000 offersthebroadestand deepestcopper accessnetwork testcapabilitiesintheindustry.Itcan be configuredtodeliver: Standard Coppe rTesting through FullSpectrum The T-BER D/MTS-4000 offersextended copper testingto quicklyand easily pinpointphysicallayerproblem s. Basicfeaturesinclude: – Digitalvolt-ohm meter (DVOM), me asuringAC and DC voltage,current, resistance,and leakage – Ground check – Opens measurement – Signalgenerator and levelmeter – Balance – Load coildetection – POTS calls – Calleridentification(CLID)testing Using O ptions,the Copper Modu lealsoOffers: – Wideband noise,impulsenoisemeters,T ransmission ImpairmentMea surement Set[TIMS];SNR; cross-talk;return loss) – Graphicalspectralanalysis(upto30 MHz) – CablefaultlocationwithgraphicalTDR or resistivefaultlocator(RFL) Com binationCopper/DSL The CopperServicesModule can be configuredasa stand-alonecopper testeror combined withmu ltipleDSL (xDSL)variantsthatsupport: – ADS L1/2/2+ – VDS L1, VDS L2 – The combinationof xD SL and copperfunctionalityprovidesthe capability to installand troubleshoottriple-playservicesand dispatchcopperissues Com bined Coppe r/DSL/Triple-PlayTesting The CopperServicesModu lecan be equippedwithan optionalxDSL modem and Triple-PlayServicessoftware,which adds thecapability to analyze dataover the optionalmo dem or thenative mainframe Ethernetportand provides: – Data throughput and We b browser – V oIPcallemulationand mon itor – IPTV (Video)settopbox emulation and monitor

The lightweight,rugged,and battery-operatedT-BE RD/MT S 4000cost-effectively scales to providean all-in-onesolutionfor fieldinstallation, maintenance,and troubleshootingacrossa wide rangeof copper,fiber, and triple-playservicestest applications.With automation featuresthat improve workforce efficiency,the T-BER D/MTS-4000 isideally suitedtosupporteventhemo stcomplex,advanced FTTx networks. T-BERD/MT S-4000 COPPER SERVICE S MOD UL E The RightToolforToday’sCopper Tests

T-BERD/MTS -4000 COP PE R SERV ICES MODU LE D VOM Me asurements AC voltage 0 to300 V peak (1% ±0.5 V) DC voltage 0 to300 RMS (1% ±0.5 V) DC current 0 to110 mA (1% ±0.5 mA) Resistance 0 to999 M Ω Resistanceaccuracy 0 to9999 Ω (1%±5 Ω) 10 to99.9k Ω(±1%) 100 to999 k Ω (±3%) 1 to9.9M Ω (±3%) Leakage(testvoltage130 V) 0 to1 G Ω Distancetoshortdistancecalculationbasedon resistance, temperature,and wiregauge O pens Measure ment Displaysthelinecapacitanceorthecalculateddistancebased on selectedcableparameters Distancerange 0 to30 km (0to100 kft) Accuracy 0 to6 km (20 kft),(±2%) N oiseand Balance Longitudinalbalance 28 to95 dB Noise(voiceband,C filter/psopho) 0 to50 dBrnC (equivalentto–90 to–40 dBm) Power (mains)influence 40 to120 dBrnC (equivalentto–50 to+30 dBm) M iscellaneous Load coildetection/count 0 to3 coils CallerID day,name, phone number,raw data Phone featurepulseorDTMF phone TD R (op tional) VeryShortrange 0 to305 m (1kft) ShortrangeTDR 0 to600 m (0to2 kft) Medium rangeTDR 30 m to2.5 km (100ftto8kft) Long rangeTDR 300 m to5 km (1to16 kft) Extendedrange 3 to8km (10to25 kft) Vp range(velocityofpropagation)0.300to0.999Gain/zoom HORZ (distance) manual VERT (amplitude) manual orautomaticTVG Graphicaldisplay,dual-tracedisplay,and cursoroperationfor comparisonwithstoredtraces Resistive FaultLocation(optional) Testmethods singlepairand separatepairhookup Faultsize(RF) 0 to20 M Ω Faultlocationaccuracy 0 to99 Ω (0.1%+0.1 Ω + RF/10M ) Loop sizeup to7000 Ω SpectralNoise Frequency LevelRange LevelRange LevelAccuracy Resolution Range (Hz) (dBm) (dBm/Hz*) (dB) (Hz) 10 to1500 +30 to–80 +28 to–82 ±2 1.5 200 to20k +13 to–50 5 to–58 ±2 15 *dB,/Hz= dBm – 10 log(FFTbinbandwidth) Narrowband Transmit Frequency Frequency LevelRange Level LevelAccuracy Range (Hz) Accuracy(Hz) (dBm) Resolution(dB) (dB) 200 to20,000 ±1 –40 to+6 1 ±0.5 200 to1,000 ±1 +6 to+10 1 1,000to20,000 ±1 +6 to+10 1 ±0.5 Narrowband Receive Frequency Frequency LevelRange Level LevelAccuracy Range (Hz) Accuracy(Hz) (dBm) Resolution(dB) (dB) 200 to20,000 ±1 +13 to–50 1 ±0.5 Wideband Transmit Frequency Frequency Frequency LevelRange Level Level Range Resolution Accuracy Resolution Accuracy 10 kHzto30 MHz 1 kHz 0.05% 15 to–40 dBm 1 dBm ±1 dB Wideband Receive Frequency Frequency Frequency LevelRange Level Level Range Resolution Accuracy Resolution Accuracy 10 kHzto30 MHz 100 Hz 0.06% ±180 Hz 15 to10 dBm 0.1dBm Indicatoronly 10 kHzto30 MHz 100 Hz 0.06% ±180 Hz 10 to–70 dBm 0.1dBm ±1 dB 10 kHzto30 MHz 100 Hz 0.06% ±180 Hz –70 to–90 dBm 0.1dBm ±2 dB Wideband NEXT Frequency Range LevelRange LevelResolution LevelAccuracy 10 kHzto30 MHz 0 to80dB 0.1dBm ±2 dB Wideband Noise Filter LevelRange (dBm) LevelResolution(dB) LevelAccuracy(dB) E (ISDN) +10 to–50 0.1 ±1 –51 to–90 0.1 ±2 F(HDSL) +10 to–50 0.1 ±1 –51 to–85 0.1 ±2 G(ADSL) +10 to–50 0.1 ±1 –51 to–85 0.1 ±2 G2(ADSL2+) +10 to–50 0.1 ±1 –51 to–85 0.1 ±2 J1(VDSL) +10 to–50 0.1 ±1 J-640K17 –51 to–70 0.1 ±2 J2 (VDSL) +10 to–50 0.1 ±1 J-17M25 –51 to–70 0.1 ±2 J3(VDSL) +10 to–50 0.1 ±1 J-17M30 –51 to–70 0.1 ±2 J4(VDSL) +10 to–50 0.1 ±1 J-25M30 –51 to–80 0.1 ±2 J6 (VDSL) +10 to–50 0.1 ±1 J-20K12 –51 to–65 0.1 ±2 J7 (VDSL) + 10 to–50 0.1 ±1 J-20K8 –51 to–65 0.1 ±2 J8(VDSL) +10 to–50 0.1 ±1 J20K17 –51 to–65 0.1 ±2 J9(VDSL) +10 to–50 0.1 ±1 No Filter –51 to–55 0.1 ±2

T-BERD/MT S-4000 COPPER SERVICE S MOD UL E Wideb and Imp ulseNoise Filter Center LevelRange LevelRange LevelResolution LevelAccuracy Frequency (dBm) (dBm) (dB) (dB) E (ISDN) 7.0 kHz +10 to–50 80to 140 0.1 ±1 51 to 90 141 to–175 0.1 ±2 F(HDSL) 35.0 kHz +10 to 50 80to–140 0.1 ±1 51 to 85 141 to–170 0.1 ±2 G(ADSL) 150 kHz +10 to 50 80to–140 0.1 ±1 51 to 85 141 to–165 0.1 ±2 G2(ADSL2+) 200 kHz +10 to 50 80to–140 0.1 ±1 51 to 85 141 to–160 0.1 ±2 J1(VDSL) 4.0MHz +10 to 50 80to–140 0.1 ±1 J-640K17 51 to 70 141 to 150 0.1 ±2 J2 (VDSL) 21.0 MHz +10 to 50 80to–140 0.1 ±1 J-17M25 51 to 70 141 to 150 0.1 ±2 J3(VDSL) 24.0 MHz +10 to 50 80to–140 0.1 ±1 J-17M30 51 to 70 141 to 150 0.1 ±2 J4(VDSL) 28.0MHz +10 to 50 80to 140 0.1 ±1 J-25M30 51 to-80 141 to 155 0.1 ±2 J6 (VDSL) 1.0MHz +10 to 50 80to 140 0.1 ±1 51 to 65 141 to 150 0.1 ±2 J7 (VDSL) 600 KHz +10 to 50 80to 140 0.1 ±1 J-20K8 51 to 65 141 to 155 0.1 ±2 J8(VDSL) 1.0MHz +10 to 50 80to 140 0.1 ±1 J20K17 51 to 65 141 to 150 0.1 ±2 J9(VDSL) 1.0MHz +10 to 50 80to 140 0.1 ±1 No Filter 51 to 55 141 to 145 0.1 ±2 Wideb and SpectralNoise Frequency Range LevelRange LevelRange LevelResolution LevelAccuracy 10 kHzto30 MHz +10 to–90 dBm 35 to–140 dBm/Hz 0.1dBm ±2 dB Wideb and SNR Frequency Range LevelRange LevelResolution LevelAccuracy 10 kHzto30 MHz 0 to50 dB 0.1dBm ±2 dB Wideb and ReturnLoss Frequency Range LevelRange LevelResolution LevelAccuracy 10 kHzto10 MHz 0 to50 dB 0.1dBm ±2 dB 10 kHzto10 MHz 30 to50 dB 0.1dBm Indicatoronly Wideb and Balance Frequency Range Frequency Spacing LevelRange LevelResolution LevelAccuracy 10 kHzto2.2 MHz 1 kHz 10 to60 dB 0.1dB ±1 dB 10 kHzto2.2 MHz 1 kHz >60 dB 0.1dB Indicatoronly

2.21 MHz to30 MHz 5 kHz 10 to60 dB 1 dB ±2 dB

2.21 MHz to30 MHz 5 kHz >60 dB 1 dB Indicatoronly

Wideb and FilterRanges U sed forWB SNR, WB Noise, and W B Impul se Noise Filter Spec Lower 3 dB CenterFrequency Upper 3 dB Comments E Filter IEEE Std743-1995 1 kHz 7 kHz 50 kHz FFilter IEEE Std743-1995 4.9kHz 35 kHz 245 kHz GFilter IEEE Std743-1995 20 kHz 150 kHz 1.1MHz G2Filter(akaJ5) None 20 kHz 200 kHz 2.2 MHz J1Filter None 640 kHz 4.0MHz 17.664 MHz J-640K17 J2 Filter None 17.664 MHz 21.0 MHz 25 MHz J-17M25 J3Filter None 17.664 MHz 24.0 MHz 30 MHz J-17M30 J4Filter None 25 MHz 28.0MHz 30 MHz J-25M30 J6 Filter None 20 kHz 1.0MHz 12.2 MHz J-20K12 J7 Filter None 20 kHz 600 kHz 8.5mHz J-20K8 J8Filter None 20 kHz 1.0MHz 17.0 MHz J-20K17 No Filter(akaJ9) None 20 kHz 1.0MHz 30.0MHz J-20K30

TO LL FR EE :18 66 228 3762 FA X :+1 30 1353 9216 Test& Measuremen tRegionalSales LATIN A MERICA TEL :+1 954 6 88 5660 FAX :+1 954 345 9216 ASIA PACIFIC TEL :+852 28 92 099 0 FAX :+852 28 92 077 0 EME A TEL :+4 9 71218 6 2222 FAX :+4 9 71218 6 1222 www .jdsu.com/test T-BERD/M TS -4000 COPPER SERVICE S MOD UL E Specifications OrderingInformation 4000-CU CopperServicesModule 4000-CU-VDSL-INF CopperServiceModule withInfineonVDSL/ADSL Interface 4000-TDR Time Domain Reflectometer/ReflectiveFaultLocator 4000-WBTONES Wideband Tones/SpectralAnalysis O ver-Voltage ProtectionSpecifications Mode Working Voltage TripVoltage All 250 VDC, 175 VAC RMS 350 VDC, 250 VAC +20%