2153300300 MOLEX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 1

Technical content

FORMAT: master-tb-prod-A3 REVISION: J DATE: 2020/01/14 DOCUMENT STATUS P1 RELEASE DATE 2023/03/29 05:14:41 FUNCTIONAL SYMBOLS = 0 = 0 = 0 DIVISIONAL SYMBOLS

3 CKT OVERMOLDED MINIFIT JR CABLE 180MM

DOCUMENT NUMBER DOC TYPE DOC PART REVISION

2153300300 PSD 000 C

MATERIAL NUMBER CUSTOMER SHEET NUMBER

2153300300 GENERAL MARKET 1 OF 1

CURRENT REV DESC: EC NO: 740245 DRWN: PRAVES6 2023/02/24 CHK'D: SKUMAR07 2023/03/29 APPR: SKUMAR07 2023/03/29 INITIAL REVISION: DRWN: AS20 2020/10/06 APPR: RDESAI01 2021/03/22 THIRD ANGLE PROJECTION DRAWING SERIES A3-SIZE 215330 DIMENSION UNITS SCALE mm NTS GENERAL TOLERANCES (UNLESS SPECIFIED) ANGULAR TOL ± °

4 PLACES ±

3 PLACES ±

2 PLACES ±

1 PLACE ±

0 PLACES ±

THIS DRAWING CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION A B C C D E E2 X X 2 180 ± 5 41 ± 2 FROM TO CABLE DESCRIPTION COLOR A1 B1 3CX16AWG UNSHD BK UL2464 BLACK A2 B2 RED A3 B3 WHITE ITEM MOLEX P/N DESCRIPTION QTY UOM A,B 39014031 3CKT RECEPTACLE HOUSING 555703R2210 2 PC C 39000077 MiniFit Term Crp Fem Chn Bs Tin 16awg 6 PC D -- RESIN BLEND STPRNE A/R KG E -- MOLD PART INNER CAP 4 PC F -- RESIN PP RTP 151 A NAT UL94V-0 HF A/R KG 17.50 ± 2 12.1 ± 2 A A B B C C D D E E F F 4.7 FD F NOTES: 1. MOLDING MATERIAL: 1.1 INNERCAP: PA66 NYLON RESIN. 1.2 OVERMOLD: SANTOPRENE TPE RESIN.

1.3 INNERMOLD: PP NAT UL94V-0

  1. ELECTRICAL PERFORMANCE: 2.1 VOLTAGE RATING: 300V AC. 2.2 THIS PRODUCT MUST PASS 100% CONTINUITY TEST PER MOLEX ES-36586-004. 1) DIELECTRONIC STRENGTH: 500V DC/0.01 SEC. 2) INSULATION RESISTANCE: 20M OHMS 3. CONNECTOR VIEWS ARE SHOWN FROM MATING SIDE. 4. MECHANICAL PERFORMANCE:

4.1 CABLE HARNESS SHOULD WITHSTAND AN AXIAL FORCE OF 5KGF FOR ONE MINUTE BETWEEN OVERMOLD

AND CONNECTOR WITHOUT PHYSICAL DAMAGE.

4.2 OVERMOLD SIDE CAN PASS THE BENDING TEST IN 100 CYCLES AT EACH OF 2 PLANES,

PER EIA364-41 CONDITION I.